6. Remote Mounted Display Units with Junction Box
PNEG-2340
Feed-Link 2
23
Connecting the Ten (10) Conductor Cable to the Display Unit
The maximum distance, the display unit can be mounted away from the junction box is 1000'. Insert the
ten (10) conductor cable through the large single-hole grommet in the bottom center of the display unit.
The ten (10) conductor cable connects to the top eight (8) terminal connector at the top center of the
display unit and the two (2) terminal connector labeled “12 VDC Out” just to the right. Connect the red wire
to the “12 VDC Out” terminal marked “+”. Connect the black wire to the “12 VDC Out” terminal marked
“-”. Connect the remaining eight (8) wires to the top eight (8) terminal connector based on the same color
scheme
Figure 6B Display and Junction Box Wiring Diagram