2
TABLE OF CONTENTS
Product Description ……………………………………………… 3
Specifications /Package Inclusions …………………………... 4
Safety Precautions …………………………………………….… 5
Control Panel Guide …………………………………..………… 6
Operating Guidelines …………………………………..….. 7—8
Digital Calibration ……………………………………….…. 9– 10
Care and Maintenance ………………………………………….. 11
This manual is designed to familiarize and instruct the
operator with the proper usage and maintenance of the
equipment. The “Care and Safety Precautions” section
explains the hazards of using any type of soldering or
reworking device. Please read carefully and observe the
guidelines in order to maximize usage and minimize the
risk of injury or accidents .
11
BASIC TROUBLESHOOTING GUIDE
PROBLEM 1: THE UNIT HAS NO POWER
1. Check if the unit is switched ON. Power switch located at the back.
2. Check the fuse. Replace with the same type if fuse is blown.
3. Check the power cord and make sure there are no disconnections.
4. Verify that the unit is properly connected to the power source.
PROBLEM 2: TEMPERATURE DISPLAY SHOWS “Err”
Description:
Digital display shows the message “Err” upon turning on the
solder pot heating function.
SOLUTION:
Sensor is damaged or loose .
PROBLEM 4: ACTUAL TEMPERATURE IS NOT RISING, DISPLAY
SHOWS “Err”
Description:
Digital display shows the message “Err” after a few minutes of
the actual temperature not rising .
SOLUTION:
Sensor tip was did not come in contact with the molten solder. Adjust sensor
armature such that sensor is dipped into the molten solder. The heating
elements may have reached the end of its life.
PROBLEM 5: UNIT SHOWS UNCONVENTIONAL BEHAVIOR
Description: Unit operates erratically.
SOLUTION1:
Try to switch OFF the device and switch ON again. Unplug the
system from the main power source and plug in again.
OTHER PROBLEMS NOT MENTIONED:
Contact the vendor.