Table 3-6-1:Specifications of mains input
Model
Dura ARC200/200II
Dura ARC250
1- phase AC230V
±
15%, 50/60Hz
Power supply
Electricity grid min. capacity (
)
KVA
Cable size
(
)
mm
Fuse
Circuit breaker
Input cable
Output cable
Protective GND wire
Input
protection
(A)
25
16
≥
2.5
70
60
12
16
≥
2.5
The connection between input cable and distribution box (Fig. 3-6-1)
Warning!
- Never perform hot-line work!
- Electric connection should be done by professional electrician!
- Two machines should not be connected to the same one circuit breaker!
- Check the input voltage, circuit breaker, input cable in accordance with Table 3-6-1.
Specifications of mains input
Fig. 3-6-1: Connection between input cable & distribution box
Power socket and using region
Table 3-6-2: Power socket selection
A: 2-plug flat type
B: 2-plug flat + GND
round hole type
L
N
C: 2-plug flat 8 type
12
E
N
L
E
L
N
GND/PE earth
ground
AC230V
±
15%
GND
Yellow-green mixed wire is used
for grounding! Not connected to
zero wire! Please connect
according to picture or other
correct way. Please disconnect
mains power when connecting!
Dura ARC160/160II
9
16
Содержание Dura ARC160