3. There should be no wind in the welding station, if any, it should be covered.
4. The welding machine is more than 20cm away from the wall, and the distance
between the welding machine is more than 10cm.
5. When using water-cooled welding torch, pay attention to anti-freezing.
●
Power supply and cable requirement
Please note the size of fuse and circuit breaker in the table below are for reference only.
Table4-7-1: Power supply and cable requirement
Note!
Welding machine must be taken special design if it is powered by generator,
Please contact with manufacturer if you have such needs.
●
Connections of power cord and distribution box
Warning!
-Avoid hot-line work
- Operating by professional electrician
- Avoid connecting two power sources to one breaker
- Please refer to Table 4-7-1 to check if standard of input voltage, breaker and
input cable is suitable
Model
350
500
Power supply (3 phase)
AC380/400/415/440/460/480/525V
±10%, 50/60Hz
Electricity grid min.
power (KVA)
Power grid
22
31
Generator
30
48
Input protection(A)
Fuse
30
50
Circuit breaker
32
63
Cable size (mm²)
Power cord
≥4
≥6
Welding cable
50
70
Protective GND wire
≥4
≥6