AOR AR-IQ-III Скачать руководство пользователя страница 20

17 

 

8-5 Demodulation modes 

 

The following modes can be used: 

AM, SAM (SYNC AM), CW, RTTY, LSB, USB, FM, WFM, USER 

 

 

8-6 Volume & mute 

 

Volume control is on the bottom right of the software, though many  users prefer to use  the volume on their external 

amplifiers. The button above the volume slider enables the audio output and mutes it when disabled. 

 

8-7 Noise reduction 

 

The NR control reduces background noise and is activated by the button above its slider control. The NR slider controls 

the amount of noise reduction. The noise reduction can be activated in all modes except with the USER demodulator.     

 

8-8 Noise blanker (NB)   

 

The NB control reduces impulsive noise and is activated by the button above its slider control. The NB slider sets the 

threshold  of  the  noise  blanker.  Care  should  be  exercised  when  strong  signals  are  present  in  the  band  where  the 

receiver is tuned. A too low NB threshold (NB slider at or near its maximum position) may affect the quality of the tuned 

signal and introduce intermodulation distortions. 

Two noise blankers can be selected with the two buttons "NBW" (Wide) and "NBN" (Narrow). 

 

The Narrow NB, operates on the bandwidth selected with the BW buttons (50 kHz, 25 kHz, 12 kHz, etc.). 

The Wide NB is more effective when there are no strong signals in the bandwidth the DDC is tuned to. 

The Narrow NB is more effective in all other cases. 

 

8-9 S-meter 

 

The signal strength meter (S-meter) is marked in both S points and dBm (S9=-73 dBm input). The S-meter response is 

very linear thorough all its scale and accurate to within less than 1 dB across the range.     

LOCK indication:

 When operating in Sync AM mode (SAM), a small "LOCK" display appears at the top right of the 

meter, when the demodulator locks on to the AM carrier.   

Содержание AR-IQ-III

Страница 1: ...AR IQ III Receiver control I Q recording playback for AR2300 AR5001D AR6000 receivers Operating manual AOR Ltd Authority On Radio Communications...

Страница 2: ......

Страница 3: ...ctrum waterfall window 9 6 2 1 Wheel step 9 6 2 2 Frequency tuning by double click on spectrum 10 6 2 3 Frequency tuning by mouse drag on spectrum 10 6 2 4 Frequency tuning with center button ON 10 6...

Страница 4: ...a time I Q allows you to store and playback a full 0 9MHz bandwidth with no loss of quality This 0 9MHz bandwidth can be anywhere within the receiving range of the receiver Off line you can listen an...

Страница 5: ...to install One for the I Q output and one for the receiver control All following instructions and screenshots are based on the Windows 10 operating system Switch the receiver ON Depending on your Win...

Страница 6: ...etected as an unknown device Right click it and select update driver Insert the supplied driver CD into your computer and select the corresponding drive Next will load and install the driver This is h...

Страница 7: ...ver from the supplied CD The connection has been flagged with a yellow exclamation mark under Other devices Right click it and select update driver Insert the supplied driver CD into your computer and...

Страница 8: ...ngle is unique and cannot be copied or backed up If you damage the USB license dongle a new one needs to be purchased Inside the USB dongle locate the software s executable ariq3 exe and double click...

Страница 9: ...s say you are tuned to 101 756 MHz and you hover the mouse over the third digit 1 Then by scrolling up or down you will change the tuned frequency of 1 MHz for each scroll increment If you wish to tu...

Страница 10: ...eded anymore 6 1 3 Frequency tuning by CF step Clicking on the buttons with the white triangle on either side of the main spectrum control bar does increment or decrement the frequency by the step siz...

Страница 11: ...e frequency on the frequency panel do not change Convenient for co channel interference removal b Notch mode not active in WFM mode The notch function is effective for cycle noise on the receive signa...

Страница 12: ...ency You can chose between spectrum view and waterfall view Main spectrum view Waterfall view 6 2 1 Wheel step This is the value by which the spectrum will be shifted by scrolling the mouse wheel when...

Страница 13: ...your mouse inside the grayed out range of the IF filter until the mouse pointer changes to a horizontal double arrow then drag the mouse either left or right on to the spectrum while pressing the left...

Страница 14: ...6 2 6 Span The span is the width of the main spectrum window You can chose between 900 9kHz 450 4kHz 225 2kHz 112 6kHz 56 3kHz 28 2kHz 14 1kHz 7 0kHz 3 5kHz Used in both live reception and playback P...

Страница 15: ...minimum Freq offers the best performance at the expense of a slight degradation of the signal amplitude accuracy and refresh rate Time Selects the FFT algorithm of previous software versions FFT with...

Страница 16: ...om the spectrum waterfall display Delta button This button changes the values from the markers 2 to 8 to delta values different from MRK 1 Labels button Activates a vertical scale at the left side of...

Страница 17: ...assband tuning etc Javailable as in a live reception situation The software will automatically divide the recording into wav files of approx 2GB which corresponds to approx 4 minutes of recording Alth...

Страница 18: ...back the whole series of files if required This playback should be continuous and flawless even during track file change During playback the software will display date and time in the same format as d...

Страница 19: ...na socket 1 even though it s usually 2 when the receiver is used stand alone This is due to the fact that the receiver s internal antenna wiring is different when used stand alone vs controlled by sof...

Страница 20: ...anker Care should be exercised when strong signals are present in the band where the receiver is tuned A too low NB threshold NB slider at or near its maximum position may affect the quality of the tu...

Страница 21: ...lch auto mute Squelch and Auto Mute threshold levels can be controlled clicking the desired value in the S Meter bar with the left button of the mouse The Auto Mute function works in the opposite way...

Страница 22: ...ton In this case the audio output level is controlled by the VOLUME slider When the AGC is off large input signals can cause the saturation of the audio output 8 12 AGC spike rejection The Spike Rejec...

Страница 23: ...the software s Buffer Reads Interval to match your PC s specifications This parameter controls the amount of data that the software reads from its data queue in a given time interval If you increase...

Страница 24: ...6 4 Misuji Taito Ku Tokyo 111 0055 Japan URL www aorja com US distributor AOR USA INC 20655 S Western Ave Suite 112 Torrance CA 90501 Phone 310 787 8615 Fax 310 787 8619 URL www aorusa com e mail inf...