AOpen Fortress 1120 Скачать руководство пользователя страница 23

11

5

CPU fan connector (CPU FAN2)

6

CPU socket

7

ServerWorks

®

 CMIC-SL (north bridge)

8

CPU fan connector (CPU FAN1)

9

Primary IDE RAID connector

10

Primary IDE connector

11

CD-ROM and HHD power jumper (JP4)

12 -14 

DIMM slots

15

Intel

®

 82540EM Gigabit Ethernet controller chipset

16

Power connector for Server Management Card

17

IPMB (Intelligent Platform Management Bus) signal connector

18

Intel

®

 82550PM Server Ethernet controller chipset 

19

ATI Rage XL VGA chipset 

20

ServerWorks

®

 CSB6 (south bridge)

21

NS 87414 Super I/O chipset

22

Boot block jumper (JP3)

23

System fan connector (SYSFAN1)

24

IPMI BIOS

25

System BIOS

26

Battery

27

System fan connector (SYSFAN2)

28

Clear CMOS jumper (JP1)

No.

Description 

Fortress 1120 ug - EN .book Page 11 Monday, February 17, 2003 3:41 PM

Содержание Fortress 1120

Страница 1: ...Fortress 1120 User s guide...

Страница 2: ...xed to your computer All correspondence concerning your unit should include the serial number model number and purchase information No part of this publication may be reproduced stored in a retrieval...

Страница 3: ...A digital device pursuant to Part 15 of the FCC rules and meets all requirements of the Canadian Interference Causing Equipment Regulations These limits are designed to provide reasonable protection a...

Страница 4: ...lded cables to maintain compliance with FCC regulations Notice Peripheral devices Only peripherals input output devices terminals printers etc certified to comply with the Class B limits may be attach...

Страница 5: ...ngs must not be blocked or covered The openings should never be blocked by placing the product on a bed sofa rug or other similar surface This product should never be placed near or over a radiator or...

Страница 6: ...oper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal condition e If the product has been dropped or t...

Страница 7: ...e setting up During installation and before operating the device observe the instructions on environmental conditions for you device refer to page 7 If the device is brought in from a cold environment...

Страница 8: ...during a power outage In emergencies e g damaged casing elements or cables penetration of liquids or foreign matter switch off the device immediately remove the power connector from the grounded powe...

Страница 9: ...only be replaced with identical batteries or with a type recommended by the manufacturer Do not throw batteries into the trash can They must be disposed of in accordance with local regulations concer...

Страница 10: ...hed on until they need to be used and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw a...

Страница 11: ...Compliance standards 6 Mechanical values 6 Environmental conditions 7 Noise level 7 External and internal structure 8 Front panel 8 Rear panel 9 Mainboard layout 10 2 System setup 15 Pre setup remind...

Страница 12: ...data protection 30 BIOS Setup security functions 30 System troubleshooting 31 FAQs 31 Appendix A System rack installation 35 Guidelines in rack installation 37 Rack installation precautions 37 System...

Страница 13: ...1 System tour...

Страница 14: ...This chapter discusses the key features and components of your system...

Страница 15: ...allation on page 35 The Fortress 1120 server offers a high level of reliability and availability through highly developed hardware and software components These include the following IPMI 1 5 complian...

Страница 16: ...CC DDR PC1600 PC2100 memory modules for a maximum capacity of 3 0 GB Two 2 64 bit 33 MHz PCI slots Fixed 200W standard power supply unit with fan adjusts automatically to a power voltage in the range...

Страница 17: ...availability and reliability features When memory data are accessed 1 bit errors in the main memory are recognized and automatically corrected with the ECC method The PDA Prefailure Detection and Anal...

Страница 18: ...wer fuse 16 A 6 3A Protection class I Product safety and ergonomics IEC 60950 EN 60950 UL 1950 CSA 22 2 No 950 Electromagnetic Compatibility standard power supply FCC class A VCCI class A AS NZS 3548...

Страница 19: ...n during operation must be avoided Noise level Environment class 3K2 Environment class 2K2 DIN IEC 721 section 3 3 DIN IEC 721section 3 2 Temperature Operation 3K2 Transport 2K2 10 C 35 C 25 C 60 C Re...

Страница 20: ...el No Icon Component 1 CD ROM drive with power on indicator 2 Floppy disk drive with power on indicator 3 IDE busy indicator 4 Service button and indicator 5 Health indicator 6 Power indicator 7 Power...

Страница 21: ...vailable on your server depends on the PCI boards installed The standard ports on the rear panel are marked with symbols and some are color coded No Icon Description 1 Service indicator 2 Health indic...

Страница 22: ...1 System tour 10 Mainboard layout No Description 1 Front USB connector 2 20 pin ATX power connector 3 Secondary IDE RAID connector 4 4 pin ATX power connector...

Страница 23: ...hernet controller chipset 16 Power connector for Server Management Card 17 IPMB Intelligent Platform Management Bus signal connector 18 Intel 82550PM Server Ethernet controller chipset 19 ATI Rage XL...

Страница 24: ...3 MHz PCI bus slot with low profile card PCI 2 35 Floppy disk drive connector 36 Front LED board connector 37 Serial port COM1 38 1 GbE LAN port 39 10 100 Mbit LAN port 40 Monitor VGA port 41 PS 2 key...

Страница 25: ...cuit Control system power via IPMI standard Control system power via south bridge JP3 1 2 2 3 Boot block BIOS recovery Disable boot block standard Enable boot block JP4 Power connector for CD ROM and...

Страница 26: ...1 System tour 14...

Страница 27: ...2 System setup...

Страница 28: ...This chapter gives you instructions on how to set up the system Procedures on how to connect the monitor is also explained...

Страница 29: ...d operating the Fortress 1120 server For installing the hardware and correctly operating the system it is necessary to have a knowledge of hardware and data transmission as well as basic knowledge of...

Страница 30: ...not available maintain contact with the server throughout any procedure requiring ESD protection The equipment and tools you use must be free of static charge Remove the power plug from the power sock...

Страница 31: ...ect the server cables see page 21 4 Connect the monitor and other peripheral devices refer to page 21 5 Connect the server to the power supply go to page 22 6 Turn on the server refer to page 23 7 Con...

Страница 32: ...g material as it may be required for transportation at some later date Setting up the stand alone model Position the stand alone model at the intended location Note the following The device must be pr...

Страница 33: ...o the server and peripherals Secure the data transmission cable connections e g nut retention 4 Plug all data communication cables into the utility sockets 5 Plug all power cables into the grounded po...

Страница 34: ...ase you will need to refer to the documentation that accompanies that device To connect a peripheral device plug in the device s data cable to its corresponding port on the server Refer to Rear panel...

Страница 35: ...ed the server can now turned on To switch on the system press the power button on the front panel The server performs a system test and boots the operating system If after switching on the server ther...

Страница 36: ...following a power failure depending of the settings in the BIOS Intelligent Platform Management Interface IPMI The server is switched on by an IPMI console via COM1 or RJ 45 Power status Description...

Страница 37: ...ller Configure the PCI SCSI controller as described in the manufacturer s documentation Further information is available on the driver diskettes provided To install the operating system Note If your s...

Страница 38: ...2 System setup 26...

Страница 39: ...3 System maintenance and protection...

Страница 40: ...3 System maintenance and protection 28 This chapter describes the proper way of cleaning the server and protecting it from unauthorized access A list of troubleshooting tips are also given...

Страница 41: ...er and monitor casing with a dry cloth If particularly dirty use a cloth that has been moistened in a mild domestic detergent and then carefully wrung out 4 Use a cloth for disinfection to clean the k...

Страница 42: ...a from unauthorized access By combining these options you can achieve optimum protection for your system Preventing unauthorized BIOS Setup calls You can activate this protection by setting a supervis...

Страница 43: ...to contact the AOpen technical support FAQs Below are possible situations that may arise during the use of the server with corresponding easy troubleshooting solutions Caution Always observe the safe...

Страница 44: ...able not connected 1 Switch off the monitor and the server 2 Check whether the power cable is properly connected to the monitor and to the power socket 3 Check whether the monitor cable is properly co...

Страница 45: ...he monitor controller for instructions on how to set the correct horizontal frequency for the monitor and follow the procedures accordingly There s no mouse pointer displayed on the monitor Mouse driv...

Страница 46: ...switch on your server you must change the lithium battery Go to http english aopen com tw tech contact for information on how to contact the AOpen technical support The system fails to boot The system...

Страница 47: ...Appendix A System rack installation...

Страница 48: ...This appendix describes the procedures for configuring the system in a rack mount fashion...

Страница 49: ...ng Otherwise the screw holes on the component may not match those on the rack Rack installation precautions Observe the following precautions when you install the server in the rack When connecting an...

Страница 50: ...he front mounting brackets left and right to the server with the eight screws 2 Mount the two support plates between the left and right telescopic bars with the eight screws 3 Align the telescopic bar...

Страница 51: ...row of holes and in the upper server into the upper row of holes This guarantees that enough free space is available between the servers for the leads that are to be routed To secure the telescopic ba...

Страница 52: ...x A System rack installation 40 2 The left and right mounting bracket share a common part Thus a mounting bracket could be used as either a left or right mounting bracket depending on how you turn it...

Страница 53: ...wn it should be used as a left mounting bracket and vice versa Mounting the assembly kit The Fortress 1120 server can be set up in rack mount fashion using either the DataCenter Rack or a standard rac...

Страница 54: ...at the appropriate height on the rear left support upright Note If required you can mount one additional cable clip for vertical cable routing To fasten the carrier rails no cage nuts are necessary si...

Страница 55: ...xing the carrier rails and securing the server at the front 1 Review the installation instructions in the standard rack documentation 2 Mark the position of the attachment points of the server on the...

Страница 56: ...ends of the carrier rails one fitting bracket Please note that the holes 1 must fit onto the guide nubs 2 of the carrier rails 6 Place the prepared carrier rails at the marked attachment points on the...

Страница 57: ...at the left and right support uprights 4 Mounting removing the server in the rack To finish setting up the Fortress 1120 server in rack mount fashion mount the prepared server into the assembled rack...

Страница 58: ...Appendix A System rack installation 46...

Страница 59: ...47 To remove the server from the rack 1 Press in the safety springs on both telescopic bars 2 Carefully slide out the server from the rack...

Страница 60: ...Appendix A System rack installation 48...

Отзывы: