1 System tour
6
Physical specifications
Electrical data
Compliance standards
Mechanical values
Rated voltage range
100V -127V / 200V-240V
Rated frequency
50 Hz - 60 Hz
Rated current in basic configuration
100 V - 127 V / 5.5 A
Maximum rated current
200 V - 240 V / 2.75 A
Active power
203W
Apparent power
253.75 VA
Thermal dissipation
0.169 kJ/h
Main power fuse
16 A (6.3A)
Protection class
I
Product safety and ergonomics
IEC 60950 / EN 60950 UL 1950,
CSA 22.2 No. 950
Electromagnetic Compatibility
(standard power supply)
FCC class A
VCCI class A
AS/ NZS 3548 class A
Emitted interference
EN 55022
Harmonic current
EN 61000-3-2
Flicker
EN 61000-3-3
Noise immunity
EN 55024
CE label according to EU directives
Low-Voltage Directive 73/23/EWG
Electromagnetic Compatibility 89/336/EEC
Stand-alone model
Rack model
Width
430 mm
480 mm
Depth
400 mm
400 mm
Height
43 mm or 1U
43 mm or 1U
Depth Cable
--
200 mm
Fortress 1120 ug - EN .book Page 6 Monday, February 17, 2003 3:41 PM
Содержание Fortress 1120
Страница 1: ...Fortress 1120 User s guide...
Страница 13: ...1 System tour...
Страница 14: ...This chapter discusses the key features and components of your system...
Страница 26: ...1 System tour 14...
Страница 27: ...2 System setup...
Страница 38: ...2 System setup 26...
Страница 39: ...3 System maintenance and protection...
Страница 47: ...Appendix A System rack installation...
Страница 48: ...This appendix describes the procedures for configuring the system in a rack mount fashion...
Страница 58: ...Appendix A System rack installation 46...
Страница 60: ...Appendix A System rack installation 48...