background image

Declaration of Conformity 

International Standards Laboratory

 

Report Number: ISL-99135FB

 

(NVLAP Lab. Code: 200234-0) 

 

-3-

2. 

Powerline Conducted Emissions

 

2.1  Configuration and Procedure

 

2.1.1  EUT Configuration 

 
 

The conducted emission test setups are in accordance with Figs 9, 10(a) and 10(b) of 

ANSI C63.4-1992, ET Docket 95-19, or EN55022: 1994 / A1: 1995 / CISPR 22:1993 / A1:1995/ 
A2:1997. 
 
 

The EUT was set up in the shielded room on the non-conductive table which is 1.0 by 1.5 

meter, 80cm above ground.  The wall of the shielded room was located 40cm to the rear of the EUT. 
 
 

Power to the EUT was provided through the LISN. The impedance vs. frequency 

characteristic of the LISN is complied with the limit shown on the figure 1 of ANSI C63.4-1992. 
 
 

Both lines (neutral and hot) were connected to the LISN in series at testing. A coaxial-type 

connector which provides a 50 OHM terminating impedance was provided for connecting the test 
instrument. The excess length of the power cord was folded back and forth at the center of the lead so 
as to form a bundle not exceeding 40cm in length. 
 
 

Any changes made to the configuration, or modifications made to the EUT, during testing 

are noted in the following test record. 
 
 

If the EUT is a Personal Computer or a peripheral of personal computer, and the personal 

computer has an auxiliary AC outlet which can be used for providing power to an external monitor, 
then all measurements will be made with the monitor power from first the computer-mounted AC outlet 
and then a floor-mounted AC outlet. 
 

2.1.2  Test Procedure  

 
 

The system was set up as described above, with the EMI diagnostic software running (see 

Appendix G). The powerline conducted EMI tests were run on the hot and neutral conductors of the 
power cord and the results were recorded. 
 
 

The highest emissions were analyzed in details by operating the spectrum analyzer in fixed 

tuned mode to determine the nature of the emissions and to provide information which could be useful 
in reducing their amplitude. 
 

2.1.3  EMI Receiver/Spectrum Analyzer Configuration (during swept frequency scans) 

 

 

Frequency Range: 

150KHz--30MHz 

 

Detector Function: 

Quasi-Peak / Average Mode 

 

Bandwidth (RBW): 

10KHz 

 

 

Video Bandwidth (VBW): 

10KHz 

 

Содержание CD-952E/TKU

Страница 1: ...KU Name of Responsible Party AOpen Incorporated Address of Responsible Party 7F 137 Sec 2 Chien Kuo N Road Taipei Taiwan R O C Contact Person Gerald Wang Phone No 886 2 2696 1333 Fax No 886 2 8691 223...

Страница 2: ...Drive Model CD 952E TKU Applied by AOpen Incorporated 7F 137 Sec 2 Chien Kuo N Road Taipei Taiwan R O C Test Performed by NVLAP Lab Code 200234 0 International Standards Laboratory No 21 Alley 37 Lane...

Страница 3: ...frequency scans 6 3 2 Test Data 7 4 Appendix 9 4 1 Appendix A Warning Labels 9 4 2 Appendix B Warning Statement 10 4 3 Appendix C Measurement Procedure for Powerline Conducted Emissions 11 4 4 Append...

Страница 4: ...st Date Aug 18 1999 Test Engineer David Y Y Wu The results show that the sample equipment tested as described in this report is in compliance with the Class B conducted and radiated emission limits of...

Страница 5: ...ette player Model WM FX50 9 Microsoft Joy Stick Model 90873 10 KOKA Microphone Model DM 510 11 Acer Digital Camera Model DVC VII 12 Acer USB Mouse Model MUSXT 13 Koka Headphone Model ST 8 14 Acer PC M...

Страница 6: ...the center of the lead so as to form a bundle not exceeding 40cm in length Any changes made to the configuration or modifications made to the EUT during testing are noted in the following test record...

Страница 7: ...Hot 17 790 21 60 50 00 28 40 Hot 20 400 17 90 50 00 32 10 Hot 22 260 16 60 50 00 33 40 Hot 26 720 15 30 50 00 34 70 Neutral 0 199 46 70 53 64 6 94 Neutral 0 301 34 70 50 23 15 53 Neutral 0 404 29 00...

Страница 8: ...0 60 00 27 90 Hot 16 890 33 40 60 00 26 60 Hot 20 490 30 60 60 00 29 40 Hot 24 490 25 90 60 00 34 10 Hot 26 720 24 20 60 00 35 80 Neutral 0 199 48 70 63 64 14 94 Neutral 0 298 35 20 60 30 25 10 Neutra...

Страница 9: ...ounted AC outlet 3 1 2 Test Procedure The system was set up as described above with the EMI diagnostic software running see Appendix G We found the maximum readings by varying the height of antenna an...

Страница 10: ...63 30 00 10 37 BILOG Horiz 199 94 11 40 8 40 2 29 0 00 22 09 30 00 7 91 BILOG Horiz 201 56 10 20 8 44 2 30 0 00 20 94 30 00 9 06 BILOG Horiz 333 70 10 60 14 23 3 07 0 00 27 90 37 00 9 10 BILOG Horiz...

Страница 11: ...13 00 8 20 2 23 0 00 23 43 30 00 6 57 BILOG Vert 199 45 14 30 8 38 2 29 0 00 24 96 30 00 5 04 BILOG Vert 201 55 14 20 8 44 2 30 0 00 24 94 30 00 5 06 BILOG Vert 335 60 7 10 14 23 3 08 0 00 24 41 37 00...

Страница 12: ...1 Appendix A Warning Labels Label Requirements A Class B digital device subject to Declaration of Conformity of FCC shall carry a label which includes the following statement The sample label shown sh...

Страница 13: ...that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can bedetermined by turning the equipment off an...

Страница 14: ...plane at the LISN If the EUT is supplied with a flexible power cord the power cord length in excess of the distance separating the EUT from the LISN shall be folded back and forth at the center of th...

Страница 15: ...easurements on the Open Site The radiated emissions test will then be repeated on the open site to measure the amplitudes accurately and without the multiple reflections existing in the shielded room...

Страница 16: ...is surrounded by hills measuring about 100 meters high The test platform is located on the top of the office building approximately 12 meters wide and 17 meters long The platform is located on the to...

Страница 17: ...HP85685A 2837A00816 Aug 10 1999 Feb 10 2000 Spectrum Analyzer HP8568B rev 7 4 87 2415A00491 Apr 17 1999 Oct 17 1999 EMI Receiver HP8546A rev 95 04 25 3448A00183 Sep 8 1998 Sep 8 1999 C EMI Receiver Sw...

Страница 18: ...r PC ISLPC3 N A N A Anechoic Chamber ISL SR100 7 6X5 7X5M N A Jul 18 1999 Jul 18 2000 Preamplifier HP8447D 2727A05338 Jul 18 1999 Jul 18 2000 Coaxial Cables RG 213U 1F 3 Jul 18 1999 Jul 18 2000 Field...

Страница 19: ...mber ISL 99135FB NVLAP Lab Code 200234 0 16 4 7 Appendix G Layout of EUT and Support Equipment 4 7 1 General Conducted Test Configuration Shielded Room 40 cm Non Conducted Table 80 cm Metal Ground Pla...

Страница 20: ...ration 10 M Non Conducted Table To Spectrum 80 cm To Remote Controller To Remote Controller Metal Full Soldered Ground Plane To turntable To Antenna To Antenna Antenna Mast Broadband or Dipole Antenna...

Страница 21: ...Parallel Serial ports Built on Motherboard Parallel Port one 25 pin Serial Port one 9 pin Keyboard Connector 6 pin Mouse Connector 6 pin USB Connector two 4 pin Game Port one 15 pin Speaker Port one M...

Страница 22: ...r 960063772 Power Supply Type Linear Power Adapter AC to AC Xfmr Wall Mounted Type Power Cord Nonshielded Without Grounding Pin FCC ID IFAXDM1414 Support Unit 6 Description HP Printer for parallel int...

Страница 23: ...ID C3KMGP1 Support Unit 11 Description KOKA Microphone Model Number DM 510 Serial Number N A Power Supply Type N A Power Cord N A FCC ID N A Support Unit 12 Description Acer Digital Camera Model DVC...

Страница 24: ...the video port device Monitor C Send H pattern to the serial port device Modem 1 D Send H pattern to the serial port device Modem 2 E Send H pattern to the parallel port device Printer F Send audio s...

Страница 25: ...Microphone to Mic Jack of PC 1 5M Nonshielded Undetachable Metal Head without Hood Joy Stick Data Cable Joystick to PC Joystick port 1 2M Nonshielded Undetachable Metal Head without Hood Audio in Dat...

Страница 26: ...Description CD ROM Drive Model CD 952E TKU Front Panel Load Eject Button Play Skip Button Power on Busy LED indicator Headphone Jack Volume Control Button Emergency Eject Hole Disc Tray Rear Panel Po...

Страница 27: ...random observation Normal K 2 1 28 1 14 0 54 0 58 Receiver Specification Rectangular 1 1 1 1 Antenna Factor Calibration Normal K 2 2 2 NA NA Cable Loss Calibration Rectangular 0 5 0 5 0 5 0 5 Combined...

Страница 28: ...nd bandwidth settings detector function EUT arrangements a sample calculation with all conversion factors and all other pertinent details shall be included along with the measurement results When auto...

Страница 29: ...ation of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 26 The Front View of Highest Radiated Set up For EUT The Back View of Highest Radiated Set up F...

Страница 30: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 27 4 12 Appendix L Photographs of EUT EUT 1...

Страница 31: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 28 EUT 2...

Страница 32: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 29 EUT 3...

Страница 33: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 30 EUT 4...

Страница 34: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 31 EUT 5...

Страница 35: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 32 EUT 6...

Страница 36: ...Declaration of Conformity International Standards Laboratory Report Number ISL 99135FB NVLAP Lab Code 200234 0 33 EUT 7...

Отзывы: