background image

REV 5 - 1502231100

L-C2-267

3

INSTALLING THE NEW INFRARED BURNER KIT

 1.

 Locate the new ignitor wire assembly with the insulator and 

thread the insulated wire through the hole in the forward fi re 
wall left by the old ignitor box, as shown in Fig. 3-1. Mark 
the fi re wall through the hole in the bracket on the insulator 
and drill a hole (approx. 0.09 inch dia.) in the fi re wall for the 
screw. 

 2.

 Attach the insulated portion of the ignitor wire assembly to 

the inside of the fi re wall as shown using the self-tapping 
sheet-metal screw through the bracket hole and into the hole 
drilled in step 1 (see Fig. 3-2).

 

 3.

 Position the new infrared burner gas inlet tube in the hole 

in the forward fi re wall and over the orifi ce fi tting, sliding it 
forward from behind the face frame, so the orifi ce is centered 
inside the burner gas tube. Set it gently onto the rear burner 
support, making sure the tabs on the back burner bottom 
each fi t through their respective slots in the rear burner 
support. This is critical to the safe function of the grill. (See 
Fig. 3-3 and Fig. 3-4.) 

Fig. 3-2 

Screw in the new wire insulator

Fig. 3-1 

Slide the wire through the fi re wall

Back burner 

support

Tabs

Insulator

Hole

Insulator

To front 
fi re wall

Front fi re 

wall

Ignitor 

wire

Fig. 3-3 

Setting tabs into support

Fig. 3-4 

Infrared burner installed

INSTALLATION (cont.)

Bracket 

hole

Ignitor 

wire

(Gas manifold)

(Infrared burner)

Ignitor 

electrodes

Wire insulator

Gas intake tube

Orifi ce