REV 5 - 1502231100
L-C2-267
3
INSTALLING THE NEW INFRARED BURNER KIT
1.
Locate the new ignitor wire assembly with the insulator and
thread the insulated wire through the hole in the forward fi re
wall left by the old ignitor box, as shown in Fig. 3-1. Mark
the fi re wall through the hole in the bracket on the insulator
and drill a hole (approx. 0.09 inch dia.) in the fi re wall for the
screw.
2.
Attach the insulated portion of the ignitor wire assembly to
the inside of the fi re wall as shown using the self-tapping
sheet-metal screw through the bracket hole and into the hole
drilled in step 1 (see Fig. 3-2).
3.
Position the new infrared burner gas inlet tube in the hole
in the forward fi re wall and over the orifi ce fi tting, sliding it
forward from behind the face frame, so the orifi ce is centered
inside the burner gas tube. Set it gently onto the rear burner
support, making sure the tabs on the back burner bottom
each fi t through their respective slots in the rear burner
support. This is critical to the safe function of the grill. (See
Fig. 3-3 and Fig. 3-4.)
Fig. 3-2
Screw in the new wire insulator
Fig. 3-1
Slide the wire through the fi re wall
Back burner
support
Tabs
Insulator
Hole
Insulator
To front
fi re wall
Front fi re
wall
Ignitor
wire
Fig. 3-3
Setting tabs into support
Fig. 3-4
Infrared burner installed
INSTALLATION (cont.)
Bracket
hole
Ignitor
wire
(Gas manifold)
(Infrared burner)
Ignitor
electrodes
Wire insulator
Gas intake tube
Orifi ce