YAG Pulse Laser Power Supply For Welding System
150W/300W/600W Operation Manual
Shenzhen Anzhong Power Co., Ltd http://www.szazdq.com
- 15 -
6.3.3 “Weld Set” Introduction
If you want to modify the Ramp Up/Down parameters,please enter this page.
【
1
】
Rise Num:
:
Ramp up points.
【
2
】
Fisrt Ratio:The first point propotion of the peak input percent.
【
3
】
Rise Ratio:Propotion of progressively increased between the ramp up pinots.
【
4
】
Down Num:Ramp down points.
【
5
】
Last Ratio:The last point propotion of the peak input percent.
【
6
】
Down Ratio:Propotion of progressively decreased between the ramp up pinots.
【
7
】
Num Switch:Turn ON the “Num switch” before welding.System will record all of the points
after print a complete image,and display in the “Total Num”.Please turn OFF the “Num Switch” when
you finish the welding.And then turn ON the “Weld Switch” to input the Ramp up/down
parameters.Press “Save”, system parameters will be automatically updated to that you setted .
(
For
the switch,“Yellow”is ON,“Gray ”is OFF)
6.4 “Debug Mode” Introduction
Only for current mode.The current range for setting is 20A-250A;The Pulse width time range for
setting is 0.1-15ms.