As a result of the addition of functions, indication of lot No. has been changed from 3 digits (conventional format: 
year and month only) to 6 digits or 7 digits.

The master unit compatible with the word transmission function provides areas for transmission and receiving of word 
data (numerical information) such as analog data and sensing level data.
Using this function enables reduction of occupancy of bit information area by word data.
To enable word transmission, it is necessary that the system should be configured only with slave units compatible with 
the word transmission function.
A slave unit incompatible with the word transmission function cannot be connected to the AnyWireASLINK system to 
conduct word transmission.
For slave units that handle word data, word address settings are required.

[About AnyWireASLINK Ver. 1.1]

[About Lot No.]

[About Word Transmission]

*

3  Some products have no indication of function version.

Year: Numbers
 

(Lower two digits of the Christian era)

Month: Alphabet (as per the table below)

“19E” means May 2019.

Single unit simplified replacement

*

1

Word transmission

*

1

*

2

Functions available with Ver. 1.1

*

1  To use these functions, the master unit compatible with each function is required.

 

For details, refer to this manual together with the manual for the master unit.

*

2  You can use this function with the word-transmission AnyWireASLINK unit connected.

 

To handle word data, word address settings are required for slave units.

 

It depends on slave units whether word address setting is enabled or not.

New functions have been added to AnyWireASLINK products in May 2019 onward. Also, for the purpose of 
differentiation of compatible functions, indication of product lot number (lot No.) has been changed.

Compatible functions vary depending on lot No. Please understand the following description thoroughly to use each 
product.

Functions added to Ver. 1.1 are as follows:

Example:

S/W version

Year and month

H/W version

Alphabet

Month

Function version

*

3

Содержание BL287PB-02F-CC20

Страница 1: ...a potentially hazardous situation which if not handled correctly may result in personal injury or property damage CAUTION WARNING System power supply Use a stable 24V DC power supply Use of an unstab...

Страница 2: ...Lot No About Word Transmission 3 Some products have no indication of function version Year Numbers Lower two digits of the Christian era Month Alphabet as per the table below 19E means May 2019 Singl...

Страница 3: ...fied replacement function see the lot No and the manual for the slave unit When a slave unit of a new function version is replaced with that of an old function version the single unit simplified repla...

Страница 4: ...s PNP input 1 point output 1 point Function 4 This terminal can be used in connection to the AnyWireASLINK unit for word transmission Note that this terminal cannot handle word data by setting a word...

Страница 5: ...Connect AnyWireASLINK AnyWireASLINK terminator One terminator should be connected to the DP DN terminal farthest from the AnyWireASLINK master unit Connect it correctly so as not to set the wrong pol...

Страница 6: ...of crosstalk caused by transmitted signals and stabilize signals The above filters must be inserted regardless of whether power is supplied to all terminals collectively from the power supply for the...

Страница 7: ...all the DP DN 24V and 0V lines run in parallel is more than 50m 24V DC stabilized power supply General purpose power supply filter Use it if necessary 2 wire terminal 2 wire terminal 4 wire terminal 2...

Страница 8: ...dicator Red Brown 24V Black IN Blue 0V Input PNP Black OUT0 Blue 0V NPN Brown 24V Black OUT0 Black OUT1 Blue 0V Brown 24V Black OUT1 PNP Black OUT Blue 0V NPN Brown 24V Black OUT Output Input output m...

Страница 9: ...e address number within the range of bit address 0 to 254 For the input output mixed type the same address number should be assigned to both input and output Set the address number so that the area oc...

Страница 10: ...lified replacement function fails This operation occurs on the S W version B or later version 3 If ID duplication is detected when the master unit executes automatic address recognition this indicatio...

Страница 11: ...t will be in the range from 21 6 to 27 6V Recommended voltage is 26 4V Check the total length Review the total length and wire diameter of transmission line so that the load will not exceed the curren...

Страница 12: ...e output device will be damaged To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated terminal Otherw...

Страница 13: ...circuited the output device will be damaged To connect loads e g I O ports that are controlled with a power supply other than the one used for the AnyWireASLINK system always use a 4 wire isolated ter...

Страница 14: ...of conductive substances in the environment where the device is used Pollution level 2 means the occurrence of only pollution by non conductive substances In such an environment however electrical co...

Страница 15: ...ADP 87 Mounting adaptor 23 2 4 2 4 80 8 20 2 n 1 40 2 4 4 2 6 15 2 3 5 20 2 11 5 5 R 1 2 1 5 1 7 7 5 3 5 BL287 B02F CC20 15 16 Connection hook Connection hook...

Страница 16: ...ted in Japan 2013 2014 2017 2018 2019 2020 UMA 08833AM EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website...

Отзывы: