Unpacking 

Carefully unpack the  equipment  and perform  a  visual  inspection to  determine if  any 
apparent damage has occurred during shipment. Please notify the delivery carrier and 
Anywave immediately if shipment damage has occurred. Retain all original shipping 
materials. 
 
Please  locate  and  reference  the  Packing  Check  List  to  verify  you  have  received  all 
components of your system. Retain the Packing Check List for future reference.   
 
Also, please identify and remove all packing materials and supports (foam pads, etc.) 
prior to the initial turn-on of the equipment.   
 

Returns and Exchanges 

Written  approval  and  a  Return  Authorization  Number  (RAN)  are  required  from 
Anywave for all equipment returns. Please direct all return inquiries to the Anywave 
Service  Department  at 

[email protected]

providing  the  Sales  Order 

number and Serial Number(s) of the equipment. Complete details regarding the nature 
and  circumstances  of  your  return  must  be  included  in  your  RAN  request.  Proper 
handling  and  return  shipping  instructions  will  be  provided  with  an  approved  RAN 
number. 
 

Technical Support   

Technical  support  and  troubleshooting  assistance  for  Anywave  Transmitters  are 
available through the Anywave Service Department during normal business hours (8:00 
AM 

5:00 

PM 

CST) 

at 

(847) 

415-2258

.

 

Email 

questions 

to 

[email protected].

   

 
Note: For all service and support requests, you will need to provide the Serial Number 
of the equipment with your Sales Order number. For future reference, please record that 
information here:________________________________________ 
 
 
 

 

Содержание TRN-U1D

Страница 1: ...ANYWAVE TRN U1D DTV Transmitter Quick Start Guide Version 2 2 September 25 2019...

Страница 2: ...e assumed for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranti...

Страница 3: ...AN are required from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Num...

Страница 4: ...ovided as a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintena...

Страница 5: ...RN U1D C FA Quick Start Guide ACT PA U1D QSG DOC V2 2 09 25 2019 Page 5 of 16 Contents 1 Introduction 6 2 Organization of Manual 6 3 TX System Overview 7 4 TX System Interconnect 8 5 Initial Turn On 9...

Страница 6: ...ied personnel are required to install maintain and service this transmission equipment 2 Organization of Manual This Manual is broken up into several sections Section 3 TX system Overview Provides a g...

Страница 7: ...es through a final 24 hour burn in period and check out before being shut done and packed up for shipment In your shipment you should receive a copy of the following documentation Packing Checklist Tr...

Страница 8: ...h two additional single port couplers for Exciter feedback samples optional The diagram below shows the overall system interconnect between the system components To PC for EXC Remote Ctrl 192 168 1 14...

Страница 9: ...er 2 Turn ON the Exciter via its rear panel AC switch 3 Check Exciter settings Check the operating Frequency of the Exciter by navigating to the Exciter FREQ submenu simultaneously press Left and Righ...

Страница 10: ...to power To accomplish this slowly increase the drive level out of the Exciter by increasing the POWER setting in the Exciter RF submenu while watching the FWD POW power increase accordingly on the P...

Страница 11: ...of POWER as you approach the desired output level 8 Check the SNR and Shoulder LIMD and UIMD RF performance of your system on the Exciter hi level status screen as well as the exciter s pages on the P...

Страница 12: ...F is used to compute the Non Linear correction coefficients 10 Optional Step Navigate to the Exciter DPD submenu in the Advanced User menu simultaneously press Left and Right buttons then simultaneous...

Страница 13: ...r as well as on the PA s touchscreen Your TX should now be up and running properly into your load or on air antenna Continue to monitor system parameters as you allow the transmitter to operate and st...

Страница 14: ...u on the PA s touchscreen then press Network button and change the value of IP or you can change it via the PA s Web Interface please reference your PAUser Manual for details You may also network to t...

Страница 15: ...r to REMOTE mode set CTL to RMT before leaving the transmitter site The Remote Local setting is located under the SYSTEM submenu Most of the Local TX controls are available on the remote web interface...

Страница 16: ...PA U1D QSG DOC V2 2 09 25 2019 Page 16 of 16 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywavec...

Отзывы: