![Anywave TRN-U1D Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/anywave/trn-u1d/trn-u1d_quick-start-manual_2949046010.webp)
TRN-U1D-C-FA Quick Start Guide
ACT-PA-U1D-QSG-DOC-V2.2, 09/25/2019
Page 10 of 16
and REFL-POW. Visit the PA’s touchscreen, or its Web interface and verify that
the current (Cur1) are showing real values and not all 0s.
6.
You are now ready to bring the TX up to power. To accomplish this, slowly
increase the drive level out of the Exciter by increasing the POWER setting in
the Exciter RF submenu while watching the FWD-POW power increase
accordingly on the PA’s touchscreen, and its Web Interface.
Begin to slowly raise the FWD System power by using the UP button on the
Exciter, while monitoring the FWD-POW system power meter on the
Controller HOME screen as shown below.
Slowly increase
to raise FWD
SYS POWER