power meters. If any of these meters has exceeded the pre-set thresholds which can be set in the 

System Set Tap->ALARM-PARA section, then it triggers an alarm accordingly, and the amplifier 

will enter into the auto-protection mode and run at reduced power levels, or even no TX output. 

2)

 

ATT stands for the internal attenuator setting. It is normal to see ATT decrease from its maximum 

value (127) to its pre-set value (set in System Set Tap) slowly during a reboot. ATT is also used in 

AGC mode when the AGC target value is away from the free-run level. 

Important

:  If  there  is  an  alarm  that  triggers  the  amplifier  to  go  into  the  auto-protection  mode, 

then the ATT’s value will increase and the amplifier will run at reduced power to protect it from 

potential damage. This kind of power drop is by designed for protection purpose. So, if you notice 

the output power drops, please first to check if there is an alarm in the system and if the current 

ATT value (in the Status Tap) matches what is set in the System Set Tap. Don’t increase the input 

of  the  PA  (or  the  output  of  the  exciter)  without  checking  alarm(s)  and  ATT  value/setting  first. 

Otherwise, once the alarm has been cleared, you may have a much higher input level than needed, 

and it may damage the amplifier and may void the warranty. 

3)

 

AMP-TEMP  is the  internal temperature readings measured by  an  onboard  temperature sensor.  If 

this  value  is  higher  than  the  pre-set  threshold  (TEMP-MAX  in  the  System  Set 

tap->ALARM-PARA section), then it triggers an AMP-TEMP alarm, and the amplifier will enter 

into the auto-protection mode and run at reduced power levels, or even no TX output. 

4)

 

50V-CUR1 is the main transistor current readings. If this value is higher than the pre-set threshold 

(50VCUR-MAX  in  the  System  Set  tap->ALARM-PARA  section),  then  it  triggers  a  50V-CUR 

alarm, and the amplifier will enter into the auto-protection mode and run at reduced power levels, 

or even no TX output. 

5)

 

EXCITER shows which exciter is currently selected and on air. Each PA can connect with up to 

two exciters (Exciter A and/or Exciter B) as needed. 

6)

 

FREQ  is  the  current  channel  frequency  read  from  the  exciter.  If  the  internal  communication 

between the exciter and the PA is lost (via RS485), or the PA is not connected with an Anywave 

exciter, then this parameter may not reflect the actual channel information. 

Содержание PA-U1D-C-FA

Страница 1: ...ANYWAVE PA U1D C FA User Manual Version 2 2 September 25 2019...

Страница 2: ...sumed for its use The manufacturer makes no representations or warranties either expressed or implied by or with respect to anything in this manual and shall not be liable for any implied warranties o...

Страница 3: ...re required from Anywave for all equipment returns Please direct all return inquiries to the Anywave Service Department at support_us anywavecom com providing the Sales Order number and Serial Number...

Страница 4: ...ed as a general guide for trained and qualified personnel well aware of the dangers inherent in handling potentially hazardous electrical transmission equipment The installation operation maintenance...

Страница 5: ...1 Product Appearance 6 1 1 Front Panel 6 1 2 Back Panel 7 2 Specifications 8 3 Control Interface 9 3 1 Web Interface 9 3 2 Local Touch Screen User Interface 14 3 2 1 Home Screen 14 3 2 2 A B Exciter I...

Страница 6: ...stay constantly off when internal communication is abnormal LED_FWD The blue light will be on when RF_OUT has power output The blue light will be off when the RF button is turned off or the PA enters...

Страница 7: ...g function The PA will enter the auto protection mode and there will be reduced RF output or even no RF output RF_OUT Connector N Impedance 50 Note RF_OUT must be connected with a load with proper imp...

Страница 8: ...MER 32 dB VSWR 1 5 Shoulder Level 36dBc with pre correction ON Size 480mm W 89mm H 587mm L Note 1 The electrical interface characteristics are measured at the rated power Values may change 2 Operating...

Страница 9: ...r s address bar to cause a login window to pop up The admin tier provides full status and control of the PA and is accessed with a username and password of anywavecom and anywavecom case sensitive Adm...

Страница 10: ...e input of the PA or the output of the exciter without checking alarm s and ATT value setting first Otherwise once the alarm has been cleared you may have a much higher input level than needed and it...

Страница 11: ...e amplifier The higher the value the more it attenuates the input level and therefore the output level If the default 0 stands for no attenuation at all 4 stands for 1dB in attenuation 8 stands for 2d...

Страница 12: ...temperature alarm We recommend keeping those settings unchanged because they are pre set and optimized for the application before leaving the factory If they are changed without the permission of the...

Страница 13: ...IP mask and gateway of the amplifier 2 If a user cannot recall the IP and therefore cannot log in remotely after making a change he can either reset the IP back to default 192 168 1 210 from its fron...

Страница 14: ...nto 4 parts Title Bar left column Power Metering upper right Block Diagram middle right and Status Bar lower right as shown below Title Bar Shown in the picture above the Home button is highlighted in...

Страница 15: ...B Exciter Icon Screen Dual Exciters Switching Screen Pressing the Exc A B icon will bring you to the Dual Exciters Switching Screen a shown below Manual Exciter Switchover As shown above Exciter A s...

Страница 16: ...ter in the event of a problem with the on air exciter If neither of the exciters can be linked successfully i e the PA does not detect a valid RF output present from either exciter a window will pop u...

Страница 17: ...ID of 81H Pressing the Exciter A or Exciter B button will bring up a window displaying the Exciter Channel Frequency and well as the TX System SNR and Upper and Lower Shoulder metrics Please note only...

Страница 18: ...settings to the default values as shown below IP 192 168 1 210 MASK 255 255 255 0 GateWay 192 168 1 1 Set There is a Set button for each bar on this screen Pressing the Set button will lead to the co...

Страница 19: ...o exit the setting mode Don t press Ok without entering a valid number otherwise the system will fill it with all zeros instead AGC Screen This screen is used to set the AGC Reference output power of...

Страница 20: ...l navigate to the Amplifier Status Screens Temp Temperature of the amplifier V50 Reading of 50 V power supply of the amplifier Cur1 Device current Cur2 5 N A for this amplifier ATT The internal attenu...

Страница 21: ...PA U1D C FA User Manual ACT PA U1D USR DOC V2 2 09 25 2019 Page 21 of 22...

Страница 22: ...A U1D USR DOC V2 2 09 25 2019 Page 22 of 22 Anywave Communication Technologies Inc 300 Knightsbridge Parkway Suite 150 Lincolnshire IL 60069 Tel 847 415 2258 Fax 847 415 2112 Email sales_us anywavecom...

Отзывы: