4.

 

Connection and Switch Diagrams 
 

4.1

 

Connection Diagram 

 
Red: E+ 
Black: E- 
Green: S+ 
White: S- 
 
 
 
 
 
 
 
 

 
 

4.2

 

Output Port 
Refer  to  the  diagram  above,  the  left  terminal  (Io)  is  for  the 
positive terminal for current output while the right terminal (Vo) 
is  for  the  positive  terminal  for  voltage  output.  The  middle 
terminal  (-)  is  the  common  ground  for  both  current  and  voltage 
outputs.  
 
Only  the  voltage  terminals  output  can  give  complimentary 
voltage output (±10V) 

 

4.3

 

  Excitation voltage 
Through  the  slide  switch  EXC,  the  A2A-D2  can  provide  either 
12VDC or 5VDC excitation voltage to the load cell.  

 

4.4

 

Gain 
The  A2A-D2  amplifier  can  be  applied  to  any  load  cells  with  its 
specified  sensitivity.  It  can  support  4  ranges  of  Gain.  User  can 
select  suitable  gain  that  matches  to  the  load  cell’s  sensitivity, 
excitation voltage and output signal by configuring the excitation 
slide  switch  (EXC),  the  4-bit  DIP  switch,  and  the  SPAN 
potentiometer. Refer to Tables below for the DIP switch and Gain 
range selection. 

Содержание A2A-D2

Страница 1: ...Anyload Transducer Co Ltd Website www anyload com Email info anyload com Fax 1 866 612 9088 North America Toll Free 1 855 ANYLOAD 269 5623 A2A D2 V1611 Load Cell Amplifier Product Manual V1810...

Страница 2: ...D2 Amplifier Product Manual V1810 TABLE OF CONTENTS 1 Introduction 2 2 Installation 2 3 Specifications 2 4 Connection Switch Diagrams 3 5 Operations 4 6 Maintenance 6 7 Warnings and Precautions 6 8 Il...

Страница 3: ...ped with individual adjustable resistors and has a wide input signal of 0 36mV and output signal of 0 10V or 2 to 20mA The manual here provides the installation operation and calibration procedures of...

Страница 4: ...y the voltage terminals output can give complimentary voltage output 10V 4 3 Excitation voltage Through the slide switch EXC the A2A D2 can provide either 12VDC or 5VDC excitation voltage to the load...

Страница 5: ...n switches either 2 3 or 4 Table 4 4 2 Gain Switch Settings 4 bit DIP Switch No of DIP Switch Gain Range GAIN 1 217 753 2 153 303 3 103 153 4 86 118 Note If the Gain setting is not achieved during cal...

Страница 6: ...libration 5 3 Span Calibration 1 Apply load up to the max capacity of the load cell or scale max load can be at least 80 of the max capacity of load cell or scale 2 If current signal output is desired...

Страница 7: ...enced personnel 3 The amplifier can only support up to 8 load cells with 350 Ohms each or combination of multiple load cells with equivalent power consumption for 8x350 Ohms load cells 7 Warnings Prec...

Страница 8: ...GND Ground EXC Switch of excitation ZERO Zero potentiometer SPAN Span potentiometer Io Positive current output Common positive Vo Positive voltage output GAIN Gain selection IN 1 Load cell 1 connectio...