33 (54)
Instance Attributes
#
Name
Access
Type
Value
Comments
1
Status
Get
DWORD
-
Bit:
Meaning:
(reserved, set to 0)
0–3
When set to 1h, attribute #5 contains valid
configuration from DHCP or non-volatile storage.
When set to 2h, attribute #5 contains valid
configuration from hardware settings. Remaining
values are reserved for future use.
4
Multicast pending if set to 1.
5
Interface configuration pending if set to 1. A new
configuration will be loaded at the next reset.
6
AcdStatus. Set to 1 if an address conflict is
detected. Address conflict detection is enabled/
disabled in attribute #10.
7
AcdFault
8–31
(reserved, set to 0)
2
Configuration
Capability
Get
DWORD
-
Bit:
Meaning:
0-1:
Always 0. For more information, consult the CIP
specifications.
2:
Always 1. For more information, consult the CIP
specifications.
3:
Always 0. For more information, consult the CIP
specifications.
4:
Always 1. For more information, consult the CIP
specifications.
5:
The module is hardware configurable when this
bit is set to 1. The bit will be set if Modbus
register 0x5200 or 0x5201 are set during
initialization.
6:
Always 0. For more information, consult the CIP
specifications.
7:
Always 1. For more information, consult the CIP
specifications.
8 - 31:
(reserved, set to 0)
3
Configuration
Control
Get/Set
DWORD
-
Value:
Meaning
0:
Configuration from non-volatile memory
2:
Configuration from DHCP
4
Physical Link
Object
Get
Struct of:
-
-
UINT (Path size)
0002h
-
Padded EPATH
20 F6 24 03h
Path to Ethernet Link Object, Instance #3
5
Interface
Configuration
Get/Set
Struct of:
-
UDINT (IP)
IP address
UDINT (Mask)
Subnet mask
UDINT (GW)
Default gateway
UDINT (DNS1)
Primary DNS
UDINT (DNS2)
Secondary DNS
STRING
(Domain)
Default domain
6
Host Name
Get/Set
STRING
-
Host name of Anybus module
8
TTL Value
Get/Set
USINT
1
TTL value for EtherNet/IP multicast packets
Anybus
®
CompactCom
™
B40 Modbus Serial EtherNet/IP Network Guide
SCM-1202-131 1.1 en-US