AIM-DAC System
19
Anviz Global Inc
verify more than one card to pass access. The “ “is the valid time gap between two cards
verify on the DAC844. (Default is 10 second)
Anti-Passback
: enable Anti-Passback rules can be applied to each access area to prevent one
user's card or entry code from being used for two subsequent entries, and to prevent a second
entry without a previous exit. In the drop down box there are three options.
A-B
: Reader A and Reader B two readers make up an Anti-Passback application.
C-D
: Reader C and Reader D two readers make up an Anti-Passback application.
A-B C-D
: Four Readers make up two areas Anti-Passback application.
Please click “Setup” upload all the settings in the DAC844 device.
Interlock
: Enable door Interlock to prevent two doors from opening at the same time. It
should only be possible to open one door at a time with a valid user code. In the drop down box
there are three options.
A-B
: Reader A and Reader B two readers make up an Interlock application.
C-D
: Reader C and Reader D two readers make up an Interlock application.
A-B C-D
: Four Readers make up two Interlock applications.
Please click “
Setup
” upload all the settings in the DAC844 device.
Note:
The Door Interlock must have door contact equipment.