Anua Puraflo Скачать руководство пользователя страница 3

Puraflo

®

Peat 

Fiber 

Biofilter 

     

  

O

w

ne

r’s

 M

an

ua

l

1

Call:

336-547-9338

or visit:

anuainternational.com

2.0 

General Description of System

The Puraflo peat biofilter is an advanced
secondary treatment system that purifies
septic tank effluent to an extremely high
degree before final dispersal.  

A typical Puraflo peat biofilter system 
consists of:

Septic tank with a commercially-rated

effluent filter, with 1/32" filtration, 
connected to the tank outlet pipe

Dosing tank and effluent pump, or siphon,

to accommodate dosing of the septic
tank effluent onto the peat fiber media 

Biofilter modules where advanced treatment

occurs due to the physical, chemical and
biological processes that are optimized in
the peat fiber media. 

Site specific, final effluent dispersal system 

The filtered septic tank effluent is collected
under gravity in the pump tank. A timed dosing
system is activated by a programmable timer
or a siphon-dose system triggers, which
pumps the effluent through a flow splitting

inlet manifold located at the base of the
treatment modules.  An orifice plate is located
inside the top of each inlet manifold which
allows the flows to be split equally and fed
simultaneously to each biofilter module.
The inlet manifold is connected to the base
of the biofilter module and is fed upwards to
a rectangular distribution grid located 6 inches
below the top of lid.  The effluent percolates
laterally and vertically through the depth of
the peat fiber treatment media and emerges
as a clear, innocuous liquid from the base of
the system.  The treated effluent is then
collected and dispersed.  

The Puraflo peat biofilter system has been
tested, certified and listed by the National
Sanitation Foundation, International as
meeting the requirements of NSF/ANSI
Standard 40, Class 1.  Puraflo is a modular
system with each module rated for 150 gallons
per day (gpd). The range and rated capacity
of the system is therefore a multiple of the
standard unit based on the 150 gpd per
module.  Model P150N*3B, incorporating 3
modules and rated at 450 gpd, was the treat-
ment plant tested to NSF/ANSI Standard 40. 

1.0   

Classification Statement

The Puraflo peat fiber biofilter system for wastewater treatment has been tested, certified and
listed by NSF International as meeting the requirements of ANSI/NSF Standard 40, Class 1. 

Figure 1 

Typical Puraflo schematic 

Panel

Puraflo Module

Septic 

Tank

Pump 

Tank

(timed dosed)

Anua_Pflo_OwnerManual_100514_Anua_Pflo_OwnerManual_100514  10/29/14  4:32 PM  Page 1

Содержание Puraflo

Страница 1: ...raflo Peat Fiber Biofilter Owner s Manual Only modules bearing the NSF logo and designated P150N XX are certified to NSF ANSI Standard 40 Call 336 547 9338 or visit anuainternational com 2014 Anua 10 2014 ...

Страница 2: ...ump Alarm 7 5 3 Electrical Control Panel 7 5 4 Puraflo Modules 8 6 0 Vacation Seasonal and Intermittent Use 12 7 0 Homeowner Troubleshooting Checklist 13 8 0 Service Agreement 13 8 1 Initial Service Agreement 7 8 2 Extended Service Agreement 7 9 0 Emergency Contact Details 14 9 1 Manufacturer Contact Information 14 9 2 Authorized Service Provider Contact Information 14 10 0 Limited Warranty 14 Cal...

Страница 3: ...inlet manifold which allows the flows to be split equally and fed simultaneously to each biofilter module The inlet manifold is connected to the base of the biofilter module and is fed upwards to a rectangular distribution grid located 6 inches below the top of lid The effluent percolates laterally and vertically through the depth of the peat fiber treatment media and emerges as a clear innocuous ...

Страница 4: ...rm water drains should not be connected to the septic tank and landscaping should divert storm water away from the modules Use additives septic tank additives should not be introduced into the septic tank for grease reduction stimulation of biological activity or other purposes Dispose of large quantities of organic mate rial through a garbage grinder as this may organically overload the system an...

Страница 5: ...aerobic process that requires free passage of air through the module lids Do Maintain a stabilized grassed landscaped area around the modules in order to prevent soil erosion plants and suitable shrubs can also be used to enhance the appearance of the system Keep ant nests and other pests out of the treatment modules by dosing externally with suitable insecticides and pest controls as necessary Di...

Страница 6: ...Depending on use a typical home will produce sufficient sludge requiring the septic tank to be pumped every 2 to 10 years The importance of desludging can not be over emphasized since the Puraflo system is designed to treat effluent from a well functioning septic tank where a significant portion of insoluble solids have been allowed to settle out The effluent filter installed with the Puraflo syst...

Страница 7: ...o system will function normally when used in vacation seasonal or intermittent homes During normal operation of the Puraflo peat fiber biofilter a stable ecosystem exists in the peat fiber media consisting of a diverse population of microorganisms and also higher life forms During a period of reduced waste waterflowtothePuraflomodules themicrobial population correspondingly decreases in the media ...

Страница 8: ...faulty electrical system or pump is faulty 1 High water usage above design capacity activates the alarm float switch 2 Leaking plumbing fixtures 3 Leaking pump or septic tank 4 Broken timer or incorrect timer settings 5 Latched alarm 1 Pump and alarm failure due to circuit breaker switches being tripped to the off position by an electrical storm power surge or power failure 2 Pump and alarm fail c...

Страница 9: ... meters Peat modules for any structural damage accessibility adequate ventilation excess odors insect or other pest infestations Vegetative growth over the drainfield Drainfield area for surfacing of the effluent Sample of peat biofilter effluent collected form the sampling point to check for efflu ent clarity and odor note peat biofilter effluent may have a brackish to straw color from the humic ...

Страница 10: ...owner shall be notified in writing of improper system operations that cannot be corrected at the time of inspection Upon expiration of this policy our firm will offer a continuing service policy on a yearly basis to cover labor and for normal maintenance and repairs on a year by year basis Violations of warran ty include shutting off electric current to the system for more than 24 hours disconnect...

Страница 11: ...ion Name Anua Environmental Products U S Inc Address PO Box 77457 Greensboro North Carolina 27417 Office Phone 336 547 9338 Toll Free Phone 1 800 PURAFLO Fax 336 547 8559 Email Address info anua us com Website Address www anua us com 9 2 Authorized Service Provider Contact Information To identify the initial service provider for your system check the labels on the control panel and fill in the tab...

Страница 12: ...ndustry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the original retail customer of the product As herein original retail customer is defined as the purchaser who first has the plant installed or in the case of a system designed for non permanent installation the purchaser who first uses the system It is the purchaser s...

Страница 13: ...ler name phone ______________________________ ______________________________ ______________________________ Service provider name phone Regulatory Authority Permit if applicable ___________________________________________________________________________________________________ ___________________________________________________________________________________________________ Notice of Transfer I t...