7
configured to be automatically set, the Messenger will set time after every power on
and perform a time check every midnight.
The RTC can be set in one of the following ways:
Method
Description
Automatic
via Cell
This is the default setting. The
Messenger will set the RTC from an
internet NIST time server.
Manually
Set the time via the Debug port
through the Maintenance menu.
OTA/SMS
Set from an OTA config command or
an SMS config command.
Some parameters in the OPTIONS and CELL configurations are used to define how the
RTC is set.
1.3.5
Specifications
Power input:
8-32 vdc
50 mA @ 24vdc
reverse polarity protection
overvoltage protection
externally fused
Digital outputs:
transistor switch to ground (current sink)
2A @ 24vdc
current limited
overvoltage protection
Digital inputs:
two modes of operation (user selectable), voltage input or ground input
current limited
overvoltage protection
Analog input:
10-bit ADC
Ac/- 2% FS
user selectable input range: 0-1v, 0-5v, 0-10v, 0-20mA