background image

10

®

P/N 1011446 Rev. I 12/18

Problem

Possible Cause

Corrective Action

Control Display flashes PLt con-

tinuously. Product not toasting 

properly.

Platen temperature is below 545 °F (285 °C).

Allow the unit to warm up for 30 minutes and then recheck. If the 

Control Display still flashes PLt, contact your maintenance person 

or Antunes Technical Service for service.

Failed Platen Thermocouple.

Contact your maintenance person or Antunes Technical Service for 

service.

Failed Control Board

Control Display flashes Er 10 

continuously.

Control Compartment ambient temperature is 

above 150

 

°F (66

 

°C)

Verify side vents on toaster are unblocked and not near other 

heating appliances. If problem persists, contact your maintenance 

person or Antunes Technical Service for service.

Failed Cooling Fan.
Failed Control Board

Control Display Flashes SSr con-

tinuously. Product Burns.

Failed Front Platen Solid State Relay.

Contact your maintenance person or Antunes Technical Service for 

service.

Failed Control Board.
Failed Front Platen Thermocouple.

Control Display flashes Er 12 

continuously. Product not toast-

ing properly.

Loose Platen Thermocouple connection on Con-

trol Board or the Platen Thermocouple is open.

Re-secure the Platen Thermocouple to the Control Board. If the 

Control Display still reads Er 11, check the Thermocouple for 

continuity. Contact your maintenance person or Antunes Technical 

Service for service.

Failed Control Board.

Control Display flashes Er 11 

continuously. Product not toast-

ing properly.

Shorted Platen Thermocouple to ground.

Disconnect and re-secure the Platen Thermocouple connection to 

the Control Board. If the Control Display still reads Er 10, check the 

Thermocouple for continuity. Contact your maintenance person or 

Antunes Technical Service for service.

Failed Control Board

Control Display flashes StoP.

Mechanical bind in one or both conveyors.

Enter “user mode” to check the motor speed. Check both convey-

ors for mechanical binds. Test the motor. Replace necessary parts. 

Contact your maintenance person or Antunes Technical Service for 

service.

Worn or damaged Ball Bearings.
Drive chain or sprockets damaged.
Failed Motor.
Failed Control Board.

Control Display flashes SpEd.

Mechanical bind in one or both conveyors.

Enter “user mode” to check motor speed. Check both conveyors for 

mechanical binds. Replace necessary parts. Contact your mainte-

nance person or Antunes Technical Service for service.

Worn or damaged Ball Bearings.
Conveyor chains loose or damaged.
Drive chain or sprockets damaged.

Crowns and/or Heels must be 

forced into the toaster. Product 

sticking and burning.

Belts are dirty, worn, or damaged (replace every 

2-4 months).

Clean or replace Belts as described in the Maintenance section of 

this manual.

Product does not meet specifications.

Contact your product supplier.

One of the Conveyor shafts is stuck in the lower 

lock position.

Inspect positions of the shafts as described in the Maintenance 

section of this manual.

Either both Upper/Lower Conveyor locks are not 

properly locked in place.

Inspect the proper position of the locks as described in the Mainte-

nance section of this manual.

Product does not meet specifications.

Contact your product supplier.

Motor settings are incorrect.

Verify that the motor setting is set to 4000 as described in the 

Programming section of this Manual.

Side door will not close.

Either both Upper/Lower Conveyor Locks are 

not properly locked in place.

Inspect the proper position of the locks as described in the Mainte-

nance section of this manual.

The lock on the Side Door is in the locked posi-

tion when trying to close the door.

Turn the lock to the unlocked position before closing the door.

Fan is making an unusual sound.

Failed Cooling Fan.

Verify vents on toaster are unblocked and not near other heating 

appliances. Clean fans as described in the Maintenance section of 

this manual. If problem persists, contact your maintenance person 

or Antunes Technical Service for service.

Cooling Fan is dirty and needs to be cleaned.

Control Display flashes HL con-

tinuously. Product is not toasting 

properly.

Hi-Limit Control is tripped.

Allow the unit to cool and reset the Hi-Limit Control. If it trips again, 

contact your maintenance person or Antunes Technical Service for 

service.

TROUBLESHOOTING

Содержание GST-1H

Страница 1: ...P N 1011446 Rev I 12 18 Flatbread Toaster Model GST 1H Manufacturing Numbers 9210970 9210971 and 9210972 www antunes com ...

Страница 2: ...ut lined in this manual y y Malfunction resulting from improper maintenance y y Damage caused by abuse or careless handling y y Damage from moisture into electrical components y y Damage from tampering with removal of or changing any pre set control or safety device TABLE OF CONTENTS Purchased From Date of Purchase Model Number Serial Number Manufacturing Number IMPORTANT Antunes reserves the righ...

Страница 3: ...ply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician y y Do not use an extension cord with this appliance y y Electrical ground is re quired on this appliance y y Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded y y When using a chemical cleaner be sure it is safe to use on cast aluminum Observe...

Страница 4: ... 12 18 SPECIFICATIONS Model Mfg No Volts Watts Hertz Plug Description GST 1H 9210970 9210971 9210972 208 4600 60 L6 30P 30 Amp 250 Volt Straight Twist Lock 23 4 593 4 mm 17 5 443 3 mm 17 25 438 mm 26 661 8 mm 20 510 7 mm ...

Страница 5: ...1 Flatbread Toaster GST 1H OPERATION 1 Press and release the Power button to turn the toaster on Allow the toaster to warm up until USE ap pears in the display 2 Insert product into the unit using the feeder 3 Finished product drops onto the heated landing zone Light Dark Adjustments The light dark value can be adjusted when the unit is displaying USE To adjust the light dark value press the LIGHT...

Страница 6: ...ve any changes NOTE The unit exits Manager Mode after 30 seconds of keypad inac tivity SAFETY FEATURES Hi Limit Control A Hi Limit Control turns off electrical power to the heaters and control circuits and displays HL if the unit overheats To reset the control 1 Let the unit cool for 15 minutes 2 Locate the Hi Limit Controls on the rear of the unit Remove the black protective cap 3 Press and relea...

Страница 7: ...owel and allow to air dry 6 Reinstall all accessories Figure 3 7 Turn the unit on and test the unit before returning it to operation IMPORTANT DO NOT INSERT HANDS BETWEEN THE BELTS USE CARE WHEN CLEANING THE BELTS AS THEY ARE MOVING PERSONAL INJURY MAY RESULT Replacing Belts NOTE Be sure to clean and sanitize the Belts completely Failure to properly clean the Belts will shorten the life of the Bel...

Страница 8: ...f the belt is away from the direction of belt travel 5 Restore tension on the bottom belt by pushing UP and OUT Figure 4 6 Restore the tension on the top belt by pushing DOWN and OUT Figure 4 7 Lock the brackets shown in Figure 7 by rotating the highlighted pin so the brackets drop down into place Push down on each bracket to ensure they are in position 8 Reinstall the clips as shown in Figure 7 9...

Страница 9: ...of Damaged Belt Figure 10 Example of Damaged Belt Figure 11 Example of Damaged Belt Figure 12 Example of Damaged Belt BELT IS TORN AND FOLDED REPLACE BELT BELT IS MISSING SNAPS AND IS DAMAGED REPLACE BELT BELT IS TORN IN THE CENTER REPLACE BELT ...

Страница 10: ...es Technical Service for service Worn or damaged Ball Bearings Drive chain or sprockets damaged Failed Motor Failed Control Board Control Display flashes SpEd Mechanical bind in one or both conveyors Enter user mode to check motor speed Check both conveyors for mechanical binds Replace necessary parts Contact your mainte nance person or Antunes Technical Service for service Worn or damaged Ball Be...

Страница 11: ...trician for service Faulty Transformer Replace Transformer Conveyors not turning Belt is damaged Replace Belts Motor Drive Chain is detached from sprockets Reinstall the Drive Chain Failed Drive Motor Contact your maintenance person or Antunes Technical Service for service Belts are ripped or torn Rollers or Heater Cover Plates are dirty and need to be cleaned Clean Rollers and Heater Cover Plates...

Страница 12: ...age 1 50 0701003 Wire Harness Tortilla Toaster Heater 1 51 0800438 Rod Belt Cover 4 52 1001658 Label Control 1 53 1031306 Spec Label 9210970 1 54 2000259 Tube O D 1 4 X 1 625 Lg 4 55 2100212 Handle Pocket Pull Snap In 2 56 2100334 Thrust Strip Teflon 4 TEM PART NO DESCRIPTION QTY 57 2140101 Adhesive Sealant Rtv 1 58 2150172 Bearing Shaft 1 4 2 59 2150179 Sprocket 25B14 1 2 Bore 4 60 2150187 Chain ...

Страница 13: ...13 P N 1011446 Rev I 12 18 18 6 19 55 20 43 72 72 14 40 72 7 72 72 39 72 72 72 72 53 ...

Страница 14: ...14 P N 1011446 Rev I 12 18 59 79 24 62 78 78 78 62 37 2 62 11 56 46 35 44 10 46 56 78 1 62 78 3 3 10 46 56 36 12 13 11 56 46 62 78 59 65 61 59 65 61 78 62 37 78 62 36 63 63 63 63 ...

Страница 15: ...15 P N 1011446 Rev I 12 18 9 47 32 31 67 68 95 77 91 92 69 70 96 81 93 52 97 66 8 71 73 73 73 94 64 69 60 98 98 64 75 ...

Страница 16: ...16 P N 1011446 Rev I 12 18 89 41 75 74 75 42 34 21 22 27 54 89 25 17 89 26 83 86 84 80 99 99 90 27 54 21 34 16 89 42 74 87 45 89 85 86 84 4 75 75 88 ...

Страница 17: ...17 P N 1011446 Rev I 12 18 28 29 28 29 38 5 15 51 33 81 76 81 76 81 76 81 76 51 82 81 76 85 86 84 85 86 84 75 82 81 76 23 75 75 85 86 84 85 86 84 30 ...

Страница 18: ...27 26 31 32 29 30 9 6 7 5 25 16 WHT 5 20 POWER MOV CORD WIRING DIAGRAM GRN YEL 12 1 2 3 5 6 YEL BLK YEL BRN J6 BLK BRN SSR 2 SSR 1 BOTTOM TOP WHT WHT RED BLU BOTTOM TOP 4070280 J8 J4 BLU BLK TOP BOT HIGH LIMITS BLU BLK C1 RED ORG BLK BRN ORG BLK BLK RED BLK ORG BLK GRN YEL RED BLU ORG BRN RED YEL BLK RED BLK BRN 14 7 8 9 10 18 4 34 20 11 12 13 14 15 16 17 18 19 20 21 22 25 33 22 23 24 26 27 28 29 ...

Страница 19: ...19 P N 1011446 Rev I 12 18 NOTES ...

Страница 20: ...not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect volt age supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Antunes reserves the right to make changes in de...

Отзывы: