P/N 1011596 Rev. A 05/21

3

Important Safety 

 

Information

In addition to the warnings and cautions in 

this manual, use the following guidelines to 

safely operate the system:

 

y

Read all instructions before 

using equipment.

 

y

Install or locate the equipment 

only for its intended use as 

described in this manual. 

 

y

Do NOT use corrosive 

chemicals in this equipment.

 

y

Do NOT operate this equipment 

if it has a damaged cord or plug; 

if it is not working properly, or if it 

has been damaged or dropped.

 

y

This equipment should be serviced 

by qualified personnel only. Contact 

Antunes Technical Service for repair.

 

y

Do NOT immerse cord 

or plug in water.

 

y

Keep cord away from 

heated surfaces.

 

y

This equipment should be 

supplied with only cold water.

 

y

The use of saddle valves 

are not permitted. Please 

consult your local plumber.

The following warnings and cautions 

appear throughout this manual and should 

be carefully observed.

 

y

This equipment is to be installed to 

comply with the local plumbing code 

and any other applicable code.

 

y

Water pressure must not 

exceed 100 psig (690 kPa). To 

reduce water pressure, install 

a water pressure regulator and 

set to suit the application. 

 

y

When installed on metallic 

plumbing, a properly sized 

electrical bonding jumper must 

be installed across the inlet and 

outlet pipes serving this unit.

Protect from becoming dry

If the membrane dries out, irreversible 

damage to the RO membrane may result. 

Protect the filter from becoming dry by 

keeping it wet and sealed at all times.

Protect from freezing

If the RO membrane freezes during 

operation or storage, irreversible damage 

to the membrane and brittle cracking of the 

cartridge or housing may result.

Protect from direct sunlight or other UV 

sources

Avoid long-term exposure to direct sunlight 

or other UV  sources. The RO should be 

stored in a dark location.

Protect from high temperatures or 

abrupt variation in temperature

The maximum operating temperature is 

100°F (38°C). Avoid abrupt variations in 

temperature. Any temperature variation 

should be made slowly.

Protect from rough handling or 

dropping

Mechanical damage, external breakage, 

and/or internal breakage of the filter can 

result if the system is dropped or bumped. 

Handle with care at all times during 

transportation and installation.

Protect from organic solvents and 

concentrated acids

Prevent any and all contact of the 

membrane with strong solvents, solvents 

containing chlorine, or concentrated 

acids. Do NOT use strong solvents or 

concentrated acids on any plastic parts 

of the filter system. Examples of some 

solvents to avoid: acetone, methyl 

acetate (nail polish remover); hexane 

(spot removers); turpentine, toluene 

(paint thinners); dry cleaning solutions, 

insecticides.

Protect from abrasive material

The membranes must be protected from 

abrasive materials like shavings left in a 

pipe. Abrasive materials in contact with 

the membrane can cause irreversible 

damage to the membrane. All pipes must 

be flushed clean before installing the 

filter. All plastic parts of the filter system 

must be protected from sharp objects like 

knives, sand paper, or other tools. Cutting 

or nicking a plastic part can weaken it 

and cause a leak. Do NOT use abrasive 

cleansers on any plastic parts.

Protect from water hammer

The system must be protected from shock, 

pressure surges, or pulsation that may 

occur inside water pipes. Water hammer 

occurs in pipes when a valve or faucet 

shuts quickly. Install a water hammer 

arrestor (pressure vessel containing 

compressed air separated from the water 

by a diaphragm) to reduce pressure shock.

Содержание 9710141

Страница 1: ... Rev A 05 21 Reverse Osmosis System Owner s Manual Models AQ RO 400 AQ RO 600 Manufacturing Numbers 9710141 9710142 9710143 www antunes com CAUTION Read all instructions before using the unit Original Instructions ...

Страница 2: ...ee Fill in the information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the system Purchased From Date of Purchase Model Number Serial Number Mfg Number Suggested replacement period for the RO Cartridge is 1 year IMPORTANT This equipment is to be installed to comply with the basic plumbing code of the Building Officials...

Страница 3: ...esult Protect from direct sunlight or other UV sources Avoid long term exposure to direct sunlight or other UV sources The RO should be stored in a dark location Protect from high temperatures or abrupt variation in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or droppi...

Страница 4: ... AQ RO 400 Reverse Osmosis Cartridge Single Pack 7002303 AQ RO 600 Reverse Osmosis Cartridge Single Pack 7002304 Replacement Cartridges CAUTION When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit CAUTION To ensure proper installation wall anchors for unit must be rated for AT LEAST 60lbs 30 kg or MORE ...

Страница 5: ...ex 5 5 Iron Hydrogen Sulfide or Manganese 0 0 Nominal Capacity 400 600 Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 70 psig Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 80 psig Performance Claims for Percent Reduction Substance Minimum Reduction Total Dissolved Solids TDS 94 NOTE Do not use with water that is microbiologically unsafe or of unknown quality wi...

Страница 6: ... P N 1011596 Rev A 05 21 6 Water Mark Listing ...

Страница 7: ...ut the system will not flush This will cause the RO membrane to plug prematurely and reduce the life of the RO System y Tank Full Mode When the tank is full no water runs out of the drain line CAUTION Stopping the drain flow can cause the Filter to plug prematurely and may reduce the life of the filter Consult the factory for more information Figure 1 System Components Figure 2 Water Connections T...

Страница 8: ...s and supplies are suggested to help with the installation y Screwdriver y Adjustable Wrenches y Drill with Bits y Level y Tape Measure y Pipe Dope or Thread Seal Tape y Two Gallon Bucket y Fresh Unscented Liquid Chlorine Bleach y Pipe Wrenches y Hose or pipe for drain line Mounting the System The RO System comes with a Mounting Bracket for the system When mounting the system pay attention to the ...

Страница 9: ...lips beside the filtration system with the appropriate mounting hardware NOTE Pay attention to the distance between the two clips it is recommended that the distance be approximately 2 3 the length of the UV light 2 Take out the UV bulb and the power supply from the box 3 Insert the bulb into the UV housing Only keep the end of the bulb out 4 Connect the bulb and the power supply 5 Attach the powe...

Страница 10: ...e and slope downwards without any kinks or loops y The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 7 This air gap protects the system from contamination in the event of a backed up drain y The drain used must not be blocked or restricted y The drain used must be as large or larger than the drain line plumbing y The drain line from the system should b...

Страница 11: ...e starts to calculate When the running time is activated on the RO membrane the RO membrane lifetime is based on the calendar time and running time which value is reached first Items Status Filters F1 Prefilter a 10 100 Life Always on b 0 10 Life Symbol Flickering c 0 Life Symbol Off Maintenance IL on Buzz 3 times min F2 Carbon F3 RO Membrane Status PROCESSING a Letter on flickering system flushin...

Страница 12: ... not already installed install the Pre filters and RO Membrane The white sediment prefilter must be installed in the left prefilter housing closest to the water inlet The carbon prefilter must be installed in the right prefilter housing after the sediment prefilter The RO membrane must be installed with the brine seal on the right nearest to the RO membrane housing inlet It should only be inserted...

Страница 13: ... and let water into the system 6 Plug the power cord into an outlet The pump will come on and air in the pre filters and RO membrane will come out Wait 5 10 minutes until all air has been removed 7 Adjust the brine control valve so that the pressure gauge is 80 psi Opening the brine control valve increases the brine flow rate and lowers the membrane pressure and product water flow rate 8 Continue ...

Страница 14: ...e tank valve 3 Depressurize the system 4 Pull out the tube which is inserted into the RO housing s inlet 5 Using the supplied wrench unscrew the RO housing end cap and remove the old RO cartridge NOTE Water may drain from the system and cartridge as it is removed 6 Unwrap the new cartridge and record the serial number of the new cartridge 7 Check to make sure that all the O rings in the end caps a...

Страница 15: ...ord the date the cartridges where changed and the next change date Replacing the Sediment Prefilter Cartridge NOTE Always install a new Sediment Prefilter Cartridge when replacing the Carbon cartridge 1 Turn off the water to the system by closing the feed water valve 2 Close the tank valve 3 Open a valve on the line to the store to depressurize the system 4 Unscrew the bowl and remove the old sedi...

Страница 16: ...lies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection Source of compressed air manual bicycle tire pump or air compressor CAUTION Air pre charge should be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre Charge Do NOT adjust the tank air pre charge with the system under pressure CAUTION Be ...

Страница 17: ...n cartridges Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace carbon cartridges Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken membrane in RO Cartridge Replace RO Cartridge Flush runs continuously Tank pressure switch stuck open Replace tank pressure switch ...

Страница 18: ...arts Exploded View 73 32 32 1 43 51 72 62 21 21 13 24 19 24 13 21 41 41 61 4 23 56 21 57 56 37 18 13 36 13 37 18 46 45 53 53 35 40 54 16 22 48 52 14 16 13 17 27 25 16 13 2 49 63 6 20 31 50 29 30 15 16 26 55 60 21 59 19 20 13 25 40 54 55 38 38 ...

Страница 19: ...MPOUND 4 35 2170201 PRESSURE GAUGE PANEL MOUNTED 1 36 2170212 BLEND VALVE 3 8 TUBE PANEL MOUNTED 1 37 2180495 FILTER BOWL 2 38 2180495 FILTER HEAD 2 39 2180495 FILTER O RING 2 40 2180772 MOUNTING CLIP RO HSG 2 41 2180779 HOUSING BOWL AND HEAD RO 1 42 2180823 GLUE BOX RO CONTROLLER 1 43 2180824 SUPPORT FRAME RO CONTROLLER 1 44 2180825 PLASTIC CLIP M4 x 6 3mm 4 45 2190251 ADAPTOR TUBE TO 1 2 NPT 1 4...

Страница 20: ...ure F Feed Pressure psig Product Flowrate ml min Drain Flowrate ml min Percent Recovery Product TDS ppm Feed TDS ppm Percent Rejection Date Date Date Changed Sediment Next Sediment Change Changed Carbon Next Carbon Change Changed RO Next RO Change ...

Страница 21: ... P N 1011596 Rev A 05 21 21 NOTES ...

Страница 22: ...nvolved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make...

Отзывы: