background image

®

P/N 1011596 Rev. A 05/21

2

General

This manual provides important safety, 

installation, and operating procedures. 

All information contained in this manual 

should be read prior to installing and 

operating the system.  
This system is manufactured from the 

finest materials available and is assembled 

to strict quality standards. This system 

has been tested at the factory to ensure 

dependable trouble-free operation. 

Warranty 

Information

Please read the full text of the Limited 

Warranty in this manual.
If the system arrives damaged, contact 

the carrier immediately and file a damage 

claim with them. Save all packing materials 

when filing a claim. Freight damage claims 

are the responsibility of the purchaser and 

are not covered under warranty.
The warranty does NOT extend to:

 

y

Damages caused in shipment or 

damage as result of improper use.

 

y

Installation of electrical service.

 

y

Normal maintenance as 

outlined in this manual.

 

y

Malfunction resulting from 

improper maintenance.

 

y

Damage from moisture leaking into 

electrical  

components.

 

y

Damage from tampering with, 

removal of, or changing any 

preset control or safety device. 

IMPORTANT

Antunes reserves the right 

to change specifications and product

 

design without notice. Such revisions do

 

not entitle the buyer to corresponding

 

changes, improvements, additions or

 

replacements for previously purchased

 

equipment.

IMPORTANT

Keep these instructions for future 

reference.

 

If the unit changes ownership, be  sure 

this manual accompanies the equipment.

Service/Technical 

 

Assistance

If you experience any problems with the 

installation or operation of your system, 

contact Antunes Technical Service at  

+1-877-392-7854 (toll free).

Fill in the information in the next column 

and have it handy when calling for 

assistance. The serial number is on the 

specification plate located on the system.

Purchased From

Date of Purchase

Model Number

Serial Number

Mfg. Number

Suggested replacement period for the RO 

Cartridge is 1 year.  

IMPORTANT

This equipment is to be installed to 

comply with the basic plumbing code 

of the Building Officials and Code Ad

-

ministrators, Inc. (BOCA) and the Food 

Service Sanitation Manual of the Food 

and Drug Administration (FDA).

IMPORTANT

Water Flow Regulator Assemblies are 

NOT interchangeable. Operating the 

system with the wrong Water Flow 

Regulator or without a regulator can 

damage the system, cause personal 

injury, and voids the warranty!

CAUTION

When installed on metallic plumb

-

ing, a properly sized electrical bonding 

jumper must be installed across the 

inlet and outlet pipes serving this unit.

Contents

General 2

Warranty Information 

2

Service/Technical Assistance 

2

Important Safety Information 

3

Specifications 

4

Replacement Cartridges 

4

Performance Data Sheet 

5

Performance for % Reduction 

5

Water Mark Listing 

6

Operation 7

Overview 7

Installation 8

Equipment Setup 

8

Mounting the System 

8

UV Installation 

9

UV Connection 

9

Drain  Connection 

10

Controller Operation 

11

Inlet Water Plumbing 

12

System Inlet Connection 

12

Filtered Water Outlet Connection  12

Install Pre-filters RO Membrane  12

Rinsing the RO System 

13

Sanitizing the Plumbing 

14

Maintenance 

14

Replacing the RO Cartridge 

14

UV System (Option) Maintenance  14

Replacing the Carbon Cartridge   15

Replacing the Prefilter Cartridge  15

Sanitization 15

Initial Performance Verification 

16

RO Recovery Calculation 

16

Semi-Annual Tasks 

16

Check Tank Air Pre-Charge 

16

Annual Tasks 

16

Change Cartridges 

16

Troubleshooting 17

Replacement Parts  

18

Exploded View 

18

Parts List 

19

NOTES 

21

Limited Warranty 

22

Содержание 9710141

Страница 1: ... Rev A 05 21 Reverse Osmosis System Owner s Manual Models AQ RO 400 AQ RO 600 Manufacturing Numbers 9710141 9710142 9710143 www antunes com CAUTION Read all instructions before using the unit Original Instructions ...

Страница 2: ...ee Fill in the information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the system Purchased From Date of Purchase Model Number Serial Number Mfg Number Suggested replacement period for the RO Cartridge is 1 year IMPORTANT This equipment is to be installed to comply with the basic plumbing code of the Building Officials...

Страница 3: ...esult Protect from direct sunlight or other UV sources Avoid long term exposure to direct sunlight or other UV sources The RO should be stored in a dark location Protect from high temperatures or abrupt variation in temperature The maximum operating temperature is 100 F 38 C Avoid abrupt variations in temperature Any temperature variation should be made slowly Protect from rough handling or droppi...

Страница 4: ... AQ RO 400 Reverse Osmosis Cartridge Single Pack 7002303 AQ RO 600 Reverse Osmosis Cartridge Single Pack 7002304 Replacement Cartridges CAUTION When installed on metallic plumbing a properly sized electrical bonding jumper must be installed across the inlet and outlet pipes serving this unit CAUTION To ensure proper installation wall anchors for unit must be rated for AT LEAST 60lbs 30 kg or MORE ...

Страница 5: ...ex 5 5 Iron Hydrogen Sulfide or Manganese 0 0 Nominal Capacity 400 600 Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 70 psig Membrane performance after 24 hours at 77 F 25 C 500 ppm TDS and 80 psig Performance Claims for Percent Reduction Substance Minimum Reduction Total Dissolved Solids TDS 94 NOTE Do not use with water that is microbiologically unsafe or of unknown quality wi...

Страница 6: ... P N 1011596 Rev A 05 21 6 Water Mark Listing ...

Страница 7: ...ut the system will not flush This will cause the RO membrane to plug prematurely and reduce the life of the RO System y Tank Full Mode When the tank is full no water runs out of the drain line CAUTION Stopping the drain flow can cause the Filter to plug prematurely and may reduce the life of the filter Consult the factory for more information Figure 1 System Components Figure 2 Water Connections T...

Страница 8: ...s and supplies are suggested to help with the installation y Screwdriver y Adjustable Wrenches y Drill with Bits y Level y Tape Measure y Pipe Dope or Thread Seal Tape y Two Gallon Bucket y Fresh Unscented Liquid Chlorine Bleach y Pipe Wrenches y Hose or pipe for drain line Mounting the System The RO System comes with a Mounting Bracket for the system When mounting the system pay attention to the ...

Страница 9: ...lips beside the filtration system with the appropriate mounting hardware NOTE Pay attention to the distance between the two clips it is recommended that the distance be approximately 2 3 the length of the UV light 2 Take out the UV bulb and the power supply from the box 3 Insert the bulb into the UV housing Only keep the end of the bulb out 4 Connect the bulb and the power supply 5 Attach the powe...

Страница 10: ...e and slope downwards without any kinks or loops y The drain line plumbing must be positioned and secured at least 2 inches above the drain Figure 7 This air gap protects the system from contamination in the event of a backed up drain y The drain used must not be blocked or restricted y The drain used must be as large or larger than the drain line plumbing y The drain line from the system should b...

Страница 11: ...e starts to calculate When the running time is activated on the RO membrane the RO membrane lifetime is based on the calendar time and running time which value is reached first Items Status Filters F1 Prefilter a 10 100 Life Always on b 0 10 Life Symbol Flickering c 0 Life Symbol Off Maintenance IL on Buzz 3 times min F2 Carbon F3 RO Membrane Status PROCESSING a Letter on flickering system flushin...

Страница 12: ... not already installed install the Pre filters and RO Membrane The white sediment prefilter must be installed in the left prefilter housing closest to the water inlet The carbon prefilter must be installed in the right prefilter housing after the sediment prefilter The RO membrane must be installed with the brine seal on the right nearest to the RO membrane housing inlet It should only be inserted...

Страница 13: ... and let water into the system 6 Plug the power cord into an outlet The pump will come on and air in the pre filters and RO membrane will come out Wait 5 10 minutes until all air has been removed 7 Adjust the brine control valve so that the pressure gauge is 80 psi Opening the brine control valve increases the brine flow rate and lowers the membrane pressure and product water flow rate 8 Continue ...

Страница 14: ...e tank valve 3 Depressurize the system 4 Pull out the tube which is inserted into the RO housing s inlet 5 Using the supplied wrench unscrew the RO housing end cap and remove the old RO cartridge NOTE Water may drain from the system and cartridge as it is removed 6 Unwrap the new cartridge and record the serial number of the new cartridge 7 Check to make sure that all the O rings in the end caps a...

Страница 15: ...ord the date the cartridges where changed and the next change date Replacing the Sediment Prefilter Cartridge NOTE Always install a new Sediment Prefilter Cartridge when replacing the Carbon cartridge 1 Turn off the water to the system by closing the feed water valve 2 Close the tank valve 3 Open a valve on the line to the store to depressurize the system 4 Unscrew the bowl and remove the old sedi...

Страница 16: ...lies required Air Pressure Gauge 5 40 psi range 0 3 2 7 bar with tire valve Schrader Valve connection Source of compressed air manual bicycle tire pump or air compressor CAUTION Air pre charge should be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre Charge Do NOT adjust the tank air pre charge with the system under pressure CAUTION Be ...

Страница 17: ...n cartridges Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace carbon cartridges Biological growth in pipes Sanitize plumbing Water conditions changed Consider installing additional filtration Broken membrane in RO Cartridge Replace RO Cartridge Flush runs continuously Tank pressure switch stuck open Replace tank pressure switch ...

Страница 18: ...arts Exploded View 73 32 32 1 43 51 72 62 21 21 13 24 19 24 13 21 41 41 61 4 23 56 21 57 56 37 18 13 36 13 37 18 46 45 53 53 35 40 54 16 22 48 52 14 16 13 17 27 25 16 13 2 49 63 6 20 31 50 29 30 15 16 26 55 60 21 59 19 20 13 25 40 54 55 38 38 ...

Страница 19: ...MPOUND 4 35 2170201 PRESSURE GAUGE PANEL MOUNTED 1 36 2170212 BLEND VALVE 3 8 TUBE PANEL MOUNTED 1 37 2180495 FILTER BOWL 2 38 2180495 FILTER HEAD 2 39 2180495 FILTER O RING 2 40 2180772 MOUNTING CLIP RO HSG 2 41 2180779 HOUSING BOWL AND HEAD RO 1 42 2180823 GLUE BOX RO CONTROLLER 1 43 2180824 SUPPORT FRAME RO CONTROLLER 1 44 2180825 PLASTIC CLIP M4 x 6 3mm 4 45 2190251 ADAPTOR TUBE TO 1 2 NPT 1 4...

Страница 20: ...ure F Feed Pressure psig Product Flowrate ml min Drain Flowrate ml min Percent Recovery Product TDS ppm Feed TDS ppm Percent Rejection Date Date Date Changed Sediment Next Sediment Change Changed Carbon Next Carbon Change Changed RO Next RO Change ...

Страница 21: ... P N 1011596 Rev A 05 21 21 NOTES ...

Страница 22: ...nvolved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make...

Отзывы: