![Antunes 9710104 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/antunes/9710104/9710104_owners-manual_2948364013.webp)
VZN 500 SERIES
13
P/N 1013008 Rev C 11/19
®
Sanitizing the System and Lines
The plumbing must be sanitized to eliminate possible
contamination that may have occurred during the installation
process.
One ounce (30 ml) of liquid chlorine bleach (regular bleach,
unscented 5.25 % - 6 % sodium hypochlorite) or Kay-5 sanitizer
solution (Sodium Dichloro-s-Triazinetrione Dihydrate, 6%) or
equivalent can be used to sanitize the plumbing.
The Kay-5 sanitizer solution is made by dissolving a 1 oz. packet
of Kay-5 powder in 2 oz. (60 ml) of clean warm water. This can
be done by removing 1 inch from the top of the Kay-5 packet and
adding the 2 oz. of warm water to the packet. Mix with a coffee
stirrer to dissolve. When added to the system, this will create a
60-100 ppm chlorine solution.
NOTE:
Follow the handling and safety instructions
supplied with the sanitizer.
NOTE:
If installed, remove the Carbon Element and TAC
Cartridge from the system BEFORE Sanitizing.
NOTE:
Sanitizing kit is NOT supplied.
1.
Follow the steps in the
Rinsing the Ultra Filter Cartridge
in
the Installation section of this manual.
2.
Turn off the water to the system.
3.
Open the faucet or tap closest downstream to the
system.
4.
Allow the system and plumbing to drain.
5.
Allow the water to drain out of the system.
6.
Pour the sanitizer into the inlet water line fitting using a cup
or funnel. Be sure to wear protective gear and be careful not
to spill the sanitizer onto clothing or skin.
7.
Slowly turn on the water supply to the system.
8.
Allow water to flow through the system and out of the open
faucet or tap until the smell of sanitizer is present.
9.
Close the faucet or tap.
10.
Let the system stand without water flow for at least 15
minutes to allow the sanitizer to sanitize the pipes.
11.
After 15 minutes without water flow, open the faucet or tap.
12.
Allow water to flow through the system until the
presence of sanitizer is gone.
13.
Open all other faucets and taps in line with the system to
flush any remaining sanitizer from the plumbing.
14.
Close all faucets and taps.
Rinsing the Carbon Element and TAC Cartridge
The Carbon Element and TAC Cartridge MUST be rinsed
before using the system the first time and immediately after the
Carbon Element or TAC Cartridge have been replaced.
NOTE:
Wear the supplied gloves for installation and
handling of the Carbon element and TAC cartridge.
If Installed, remove the TAC Cartridge Element
before proceeding. DO NOT rinse a new Carbon
Element with the TAC Cartridge Element installed.
1.
Install the Carbon Element into the Carbon Element
Housing.
2.
Screw the Carbon Element Housing (containing the Carbon
Element) into place on the Carbon Element Head. Use the
Filter Wrench if necessary.
3.
If installed, remove the TAC Cartridge Element from the
TAC Cartridge Housing. Use the Filter Wrench if necessary.
4.
Screw the empty TAC Housing into place on the TAC Head.
Use the Filter Wrench if necessary.
5.
Direct water from the Rinse Ball Valve to a drain. Then
open the Rinse Ball Valve and close the Outlet Ball Valve.
6.
Turn on the water to the system by slowly opening the Inlet
Ball Valve.
7.
Allow water to flow through the Carbon Element and TAC
Housings to flush out trapped air and any debris that may
be present.
8.
To help remove trapped air from the Housings, press the
RED Pressure Relief Button on the top of the housings until
water just begins to come out.
9.
For
VZN-521H-T5, VZN-541H-T5, and VZN-541V-T5::
Flush the Carbon Element for at least 5 minutes.
For
VZN-521HC-T5, VZN-541HC-T5, and VZN-541VC-T5:
Flush the Carbon Element for at least 10 minutes
10.
Close the inlet ball valve and install the TAC Cartridge
Element into the TAC Housing with the arrow on the
cartridge pointing up. Reattach the TAC Housing to the
system. Open the inlet ball valve and flush for at least 5
minutes.
NOTE:
DO NOT consume water used during this process.
11.
Close the Rinse Ball Valve when rinsing completes.
12.
Open the Outlet Ball Valve. The system is now ready for
use.
13. For new piping installations:
After making the
connection to the System Outlet:
A.
Open the faucet or tap closest to the filter system
B.
Slowly open the Inlet Valve.
C.
Allow the pipe to flush until all debris is removed.