It is recommended that an optional bypass be installed to help 

with replacing cartridges and servicing the system.

1. 

Install tees on the ends of the plumbing leading to the 

Inlet and Outlet Ball Valves.

2. 

Connect the two tees by installing plumbing and a fully 

ported (preferably 3/4”) Ball Valve.

3. 

When the system is in use, open the Inlet and Outlet Ball 

Valves and close the Bypass Ball Valve.

4. 

When servicing is needed, close the Inlet and Outlet Ball 

Valves and open the Bypass Ball Valve.

Starting the Controller

1. 

Select the proper AC plug for your electrical outlet and 

install it onto the power supply.

2. 

Plug the appropriate end of the power cord into the 

controller.

3. 

Plug the other end of the power cord into the electrical 

outlet. The LEDs on the controller will light up.

4. 

The controller automatically enters Flush Mode and the 

Flush LED starts to flash.

5. 

When flushing is complete, the Flush LED will stop 

flashing and one or more LEDs will remain lit, indicating 

the unit has power and which interval is selected in the 

controller.

Rinsing the Ultra Filter Cartridge

The Ultra Filter Cartridge comes pre-installed in the VZN 

 

system. The Ultra Filter Cartridge must be rinsed before the 

system is used to remove any air and protective solution.

NOTE:

 Ultra Filter Cartridge must be rinsed to drain 

before use. Rinsing to drain removes storage 

solution and air. DO NOT rinse into carbon if 

present. Carbon life and/or performance may be 

affected.

NOTE:

 Make sure the Carbon Element and TAC Cartridge, 

if present, are NOT installed. These should only be 

installed after the Ultra Filter Cartridge has been 

rinsed.

NOTE:

 DO NOT consume water used during this process.

1. 

Direct water from the Rinse Ball Valve to a drain.

2. 

Close the Outlet Ball Valve.

3. 

Close the Inlet Ball Valve.

4. 

Open the Rinse Ball Valve.

5. 

Slowly turn on the water supply to the VZN system.

6. 

Slowly open the Inlet Ball Valve. Air and water will come 

out of the Rinse Ball Valve.

7. 

Press the 

FLUSH

 button. The Drain Valve will open and 

air and water will come out of the drain line. Repeat step 7 

six times to ensure all air and storage solution are flushed 

out of the Ultra Filter Cartridge.

8. 

Continue to allow water to run at full flow out of the Rinse 

Ball Valve for at least 15 minutes.

9. 

After 15 minutes, close the Rinse Ball Valve and allow 

the system to sit for 15 minutes without any water flow to 

release any trapped air from the Ultra Filter Cartridge.

10. 

Inspect the unit for any leaks, repairing as needed.

11. 

After 15 minutes, open the Rinse Ball Valve and wait for 

15 more minutes to flush out any remaining air.

12. 

Close the Rinse Ball Valve.

13. 

Press the 

FLUSH

 button to open the Drain Valve. Repeat 

step 13 six times to ensure any remaining air is flushed 

out of the system.

14. 

Open the closest downstream tap or faucet.

15. 

Slowly open the Outlet Ball Valve and allow water to run 

through the system and out the faucet for five minutes.

Содержание 9710104

Страница 1: ...ied and substantiated by test data Owner s Manual Original Instructions Water Filtration Manufacturing Numbers 9710104 9710105 9710106 9710107 9710111 9710113 9710114 9710115 9710116 9710117 9710118 9710119 9710120 9710128 9710132 VZN 521H VZN 521HC VZN 521H T5 VZN 521HC T5 VZN 541H VZN 541HC VZN 541H T5 VZN 541HC T5 VZN 541V VZN 541VC VZN 541V T5 VZN 541VC T5 VZN 541VE www antunes com CAUTION Rea...

Страница 2: ... filtration technology Before Use This manual provides the safety installation and operating procedures for the VZN water filtration system All information contained in this manual should be read prior to installing and operating the system Your VZN system is manufactured from the finest materials available and is assembled to strict quality standards This system has been tested at the factory to ...

Страница 3: ...suitably sized booster system outlet pressure 60 psig 100 psig max 414 kPa 690 kPa max be installed WARNING ELECTRICAL SHOCK HAZARD Failure to follow the instructions in this manual could result in serious injury or death DO NOT modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician DO NOT use an extension cord with this unit If th...

Страница 4: ...ing solutions insecticides Protect from abrasive material The membranes must be protected from abrasive materials like shavings left in a pipe Abrasive materials in contact with the membrane can cause irreversible damage to the membrane All pipes must be flushed clean before installing the filter All plastic parts of the filter system must be protected from sharp objects like knives sand paper or ...

Страница 5: ...on Configuration Kit 0012146 DC Power Supply 100 240 VAC Includes the 4 plug adaptors below US NEMA 1 15 2 pin or NEMA 5 15 3 Pin Euro CEE 7 16 AS NZS 3112 AUS 2 Pin UK BS 1363 NOTE Includes plug adaptors for US Europe Australia and UK NOTE PLUG STYLE MAY VARY US NEMA 1 15 2 PIN or NEMA 5 15 3 PIN EURO CEE 7 16 AS NZS 3112 2 PIN AUS BS 1363 UK UK Replacement Cartridges Model Ultrafilter Carbon TAC...

Страница 6: ...re or after the system Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts Performance Data Sheet Filter Cartridge Capacities Maximum Operating Pressure 100 psig 690 kPa Maximum Operating Temperature 100 F 38 C Minimum Operating Temperature 40 F 4 C Maximum Trans Membrane Pressure 45 PSI 3 1 Bar pH Range 3 10 MWCO 100 kD NSF Certified Rated Serv...

Страница 7: ...es and cleans the Ultra Filter membrane by removing any debris collecting on the membrane wall The Drain Valve is only powered during Flush Mode NOTE DO NOT unplug the power cord or turn off the system during Flush Mode If there is a power outage or the system is unplugged water will continue to be filtered but the system will NOT flush This could cause the Ultra Filter to plug prematurely and may...

Страница 8: ...O NOT connect the system to a switched electrical outlet Plumbing NOTE The system must be connected to the COLD water line DO NOT connect the system to the hot water line The VZN system uses the following connections System Inlet 3 4 FNPT System Outlet Product Water 3 4 FNPT Drain 3 4 FNPT Rinse Outlet 3 4 Garden Hose or 3 4 FNPT When making a plumbing connection to the system use a back up wrench...

Страница 9: ...th heavy duty hardware Mounting Hardware Not Supplied The system is pre assembled to a Back Panel The Back Panel has mounting holes across the bottom portion to secure the bottom of the system to the wall Some of the bottom mounting holes may be obscured Plan your mounting accordingly Follow these steps to secure the Mounting Bracket to the wall and seat the VZN system 1 Use a stud finder and leve...

Страница 10: ...s the use of an O Ring sealed union is recommended not supplied When connecting the drain hose pay attention to the following guidelines y y The drain line plumbing must be able support the flow rate whenever the system flushes This flow rate is dependent on the inlet water pressure inlet pipe size and system y y The drain line leading out of the system must be as short as possible and slope downw...

Страница 11: ...n The System Inlet has a 3 4 FNPT thread at the Inlet Valve Figure 7 DO NOT overtighten fittings as this could cause the plastic ball valve to crack Use plastic fittings and a pipe thread sealant approved for use on PVC fittings when making connections Filtered Water Permeate Outlet Connection The System Outlet has a 3 4 FNPT thread at the Outlet Valve Figure 7 DO NOT overtighten fittings as this ...

Страница 12: ...lution NOTE Ultra Filter Cartridge must be rinsed to drain before use Rinsing to drain removes storage solution and air DO NOT rinse into carbon if present Carbon life and or performance may be affected NOTE Make sure the Carbon Element and TAC Cartridge if present are NOT installed These should only be installed after the Ultra Filter Cartridge has been rinsed NOTE DO NOT consume water used durin...

Страница 13: ...the plumbing 14 Close all faucets and taps Rinsing the Carbon Element and TAC Cartridge The Carbon Element and TAC Cartridge MUST be rinsed before using the system the first time and immediately after the Carbon Element or TAC Cartridge have been replaced NOTE Wear the supplied gloves for installation and handling of the Carbon element and TAC cartridge If Installed remove the TAC Cartridge Elemen...

Страница 14: ...d Cartridge O rings for nicks or cuts Replace as needed 9 Record the serial number of the new cartridge The cartridge serial number is engraved on one end of the outer tube for example 05K 12013 10 Lubricate all O rings with a food grade silicone lubricant Apply a light coating of lubricant to the inside center tube at both ends of the new cartridge 11 Position the new cartridge into the housing a...

Страница 15: ... on the Carbon Element Head Use the Filter Wrench if necessary NOTE DO NOT overtighten the Carbon Element Housing 10 Direct water from the Rinse Ball Valve to a drain NOTE Direct the Rinse Ball Valve to a drain DO NOT use the water resulting from the flush procedure 11 Open the Rinse Ball Valve Turn on the water to the system by slowly opening the Inlet Ball Valve Allow water to flow through the C...

Страница 16: ...into place on the TAC Head Use the Filter Wrench if necessary 10 Direct water from the Rinse Ball Valve to drain NOTE DO NOT consume the water used for rinsing the TAC Cartridge 11 Turn on the water to the system by slowly opening the Inlet Ball Valve and allow water to flow through the TAC Cartridge and Housing to clear out trapped air and any fines that may be present 12 To help remove trapped a...

Страница 17: ... Figure 13 Universal Pulse Controller Semi Annual Task Check Permeate Tank Air Pre Charge It is recommended the permeate tank air charge be checked every six months Caution Air pre charge should only be checked and adjusted under zero system pressure The system must be depressurized before checking the tank pre charge DO NOT adjust the tank air pre charge with the system under pressure Caution Be ...

Страница 18: ...d Clean or replace the inlet flow restrictor Water tastes bad Carbon Element need replacing Replace Carbon Element Storage shipping solution not completely rinsed out of the system Rinse the system for a longer period of time replace Carbon Element Biological growth in pipes Sanitize plumbing Water condition changed Consider installing additional filtration Broken capillaries in Ultra Filter Cartr...

Страница 19: ...male Connector 3 4 CTS X 3 4 NPS 1 17 2190167 Garden Hose Adaptor 1 Item No Part Description Qty 18 2190210 Adaptor Tube to 1 NPT 1 19 2190210 Fitting 3 4 NPT X 3 4 CTS Stem 1 20 3000116 Retainer Nut 1 4 20 4 21 3000132 Cage Nut 8 32 2 22 4040189 Solenoid Valve 24VDC 3 4 NPT 1 23 7002014 End cap Kit SS Drain 1 24 7002025 End Cap Kit SS Inlet w Regulator 8GPM 9710106 9710107 9710128 ONLY 1 7002024 ...

Страница 20: ... 18 2190158 Female Connector 3 4 CTS X 3 4 NPS 1 Item No Part Description Qty 19 2190167 Garden Hose adaptor 3 4 NPT x 3 4 1 20 2190189 Adaptor Tube to 1 NPT 2 21 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 22 3000116 Retainer Nut 1 4 20 4 23 3000132 Cage Nut 8 32 2 24 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 25 7002014 End cap Kit SS Drain 1 26 7002025 End Cap Kit SS Inlet w Regulator 8GPM 97101...

Страница 21: ... 4 NPT x 3 4 GHT 1 18 2190189 Adaptor Tube to 1 NPT 1 19 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 20 3000116 Retainer Nut 1 4 20 4 21 3000132 Cage Nut 8 32 ZP STEEL 2 22 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 23 7002014 End cap Kit SS Drain 1 24 7002024 End Cap Kit SS Inlet w Regulator 15GPM 9710113 9710114 9710132 ONLY 1 7002025 End Cap Kit SS Inlet w Regulator 8GPM 971011 ONLY 1 25 7002015...

Страница 22: ...ALE STEM 1 17 2190155 Union Tee 3 4 CTS 2 18 2190158 Female Connector 3 4 CTS X 3 4 NPS 1 19 2190167 Garden Hose adaptor 3 4 NPT x 3 4 GHT 1 20 2190189 Adaptor Tube to 1 NPT 2 21 2190210 Fitting 3 4 MPT X 3 4 CTS Stem JG 1 22 3000116 Retainer Nut 1 4 20 4 23 3000132 Cage Nut 8 32 ZP STEEL 2 24 4040189 Solenoid Valve NC 24VDC 3 4 NPT 1 25 7002014 End Cap Kit SS Drain 1 26 7002024 End Cap Kit SS Inl...

Страница 23: ...VZN 500 SERIES 23 P N 1013008 Rev C 11 19 Notes ...

Страница 24: ...ntenance calibration or regular adjustments as specified in operating and maintenance instructions of this manual and or labor involved in moving adjacent objects to gain access to the Equipment 2 Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulatio...

Отзывы: