9
P/N 1011446 Rev. B 01/17
Problem
Possible Cause
Corrective Action
Control Display flashes
PLt
con-
tinuously. Product not toasting
properly.
Platen temperature is below 545 °F (285 °C).
Allow the unit to warm up for 30 minutes and then recheck. If the
Control Display still flashes
PLt
, contact your maintenance person
or Authorized Service Agency for service.
Failed Platen Thermocouple.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board
Control Display flashes
Er 10
continuously.
Control Compartment ambient temperature is
above 150
°F (66
°C)
Verify side vents on toaster are unblocked and not near other
heating appliances. If problem persists, contact your maintenance
person or Authorized Service Agency for service.
Failed Cooling Fan.
Failed Control Board
Control Display Flashes
SSr
con-
tinuously. Product Burns.
Failed Front Platen Solid State Relay.
Contact your maintenance person or Authorized Service Agency
for service.
Failed Control Board.
Failed Front Platen Thermocouple.
Control Display flashes
Er 12
continuously. Product not toast-
ing properly.
Loose Platen Thermocouple connection on Con-
trol Board or the Platen Thermocouple is open.
Re-secure the Platen Thermocouple to the Control Board. If the
Control Display still reads
Er 11
, check the Thermocouple for
continuity. Contact your maintenance person or Authorized Service
Agency for service.
Failed Control Board.
Control Display flashes
Er 11
continuously. Product not toast-
ing properly.
Shorted Platen Thermocouple to ground.
Disconnect and re-secure the Platen Thermocouple connection to
the Control Board. If the Control Display still reads
Er 10
, check the
Thermocouple for continuity. Contact your maintenance person or
Authorized Service Agency for service.
Failed Control Board
Control Display flashes
StoP
.
Mechanical bind in one or both conveyors.
Enter “user mode” to check the motor speed. Check both convey-
ors for mechanical binds. Test the motor. Replace necessary parts.
Contact your maintenance person or Authorized Service Agency
for service.
Worn or damaged Ball Bearings.
Drive chain or sprockets damaged.
Failed Motor.
Failed Control Board.
Control Display flashes
SpEd
.
Mechanical bind in one or both conveyors.
Enter “user mode” to check motor speed. Check both conveyors for
mechanical binds. Replace necessary parts. Contact your mainte-
nance person or Authorized Service Agency for service.
Worn or damaged Ball Bearings.
Conveyor chains loose or damaged.
Drive chain or sprockets damaged.
Crowns and/or Heels must be
forced into the toaster. Product
sticking and burning.
Belts are dirty, worn, or damaged (replace every
2-4 months).
Clean or replace Belts as described in the Maintenance section of
this manual.
Product does not meet specifications.
Contact your product supplier.
One of the Conveyor shafts is stuck in the lower
lock position.
Inspect positions of the shafts as described in the Maintenance
section of this manual.
Either both Upper/Lower Conveyor locks are not
properly locked in place.
Inspect the proper position of the locks as described in the Mainte-
nance section of this manual.
Product does not meet specifications.
Contact your product supplier.
Motor settings are incorrect.
Verify that the motor setting is set to 4000 as described in the
Programming section of this Manual.
Side door will not close.
Either both Upper/Lower Conveyor Locks are
not properly locked in place.
Inspect the proper position of the locks as described in the Mainte-
nance section of this manual.
The lock on the Side Door is in the locked posi-
tion when trying to close the door.
Turn the lock to the unlocked position before closing the door.
Fan is making an unusual sound.
Failed Cooling Fan.
Verify vents on toaster are unblocked and not near other heating
appliances. Clean fans as described in the Maintenance section of
this manual. If problem persists, contact your maintenance person
or Authorized Service Agency for service.
Cooling Fan is dirty and needs to be cleaned.
Control Display flashes
HL
con-
tinuously. Product is not toasting
properly.
Hi-Limit Control is tripped.
Allow the unit to cool and reset the Hi-Limit Control. If it trips again,
contact your maintenance person or Authorized Service Agency for
service.
TROUBLESHOOTING
Содержание 9210970
Страница 12: ...12 P N 1011446 Rev B 01 17 18 6 19 55 20 43 72 72 14 40 72 7 72 72 39 72 72 72 72 53 ...
Страница 18: ...18 P N 1011446 Rev B 01 17 NOTES ...
Страница 19: ...19 P N 1011446 Rev B 01 17 ...