background image

SE-4200/4400 WATER FILTRATION SYSTEM

8

P/N 1010852 Rev. C 04/06

2”  

minimum

2”  

minimum

Floor 

Drain

Secure 

End

Drain Line from 

System

Drain Line from 

System

Secure 

End

 

Drain

Standpipe

INSTALLATION (continued)

Locating and Mounting the system

Consider these points before mounting the system:

•  Note the location of the water supply, drain, and 

an appropriate electrical outlet when choosing a 

mounting location.  

•  Remember to allow for access to the Control Box.  
•  Do not mount the system above any electrical 

equipment or items that may be damaged if they 

get wet.  

•  Install the system in a location that will allow for 

future service access.  

•  Mount the system on a wall using appropriate 

mounting hardware.  

•  Remember to consider the operating weight of 

the system when choosing mounting hardware.  

Depending on the type of wall on which the system 

is mounted, wall reinforcement may be necessary.

INLET WATER PLUMBING

It is recommended that the inlet water plumbing line 

be 3/4” NPT or larger.  A shutoff valve (not supplied) 

should be installed in the line leading to the system.  

The valve should be mounted close to the system inlet, 

and sized properly for the inlet plumbing line.  The sys-

tem should only be connected to the cold water line.

PERMEATE LINE PLUMBING

To ensure the highest quality and safest water, it is 

recommended that a check valve (to prevent backflow) 

be installed in the water line after the permeate connec-

tion.  This will help prevent possible contamination of 

the filter system due to other equipment downstream.  

The check valve (not supplied) should be mounted 

close to the system outlet, and sized properly for the 

plumbing line.  Check with local codes for the proper 

specification.

DRAIN LINE PLUMBING

The drain line is used to flush away the particle buildup 

when cleaning the filter.  The drain line must be able 

to support the flow rate when the system flushes.  The 

flow rate from the flush depends on the inlet water pres-

sure, inlet pipe size, and system selected.  It is recom-

mended that the drain line be as large as, or larger 

than, the inlet plumbing line.  The drain line should be 

as short as possible, sloping downward without kinks 

or loops.  Be sure that the drain used is not blocked or 

restricted.  

The filter system must be protected from possible back 

contamination by the installation of an air gap between 

the drain connection of the system and the drain 

(Figure 1).  This gap in the line, with no physical contact 

between the system and sewer, prevents contamination 

of the system in the event of a backed-up sewer.  

NOTE: Make sure that the end of the drain line is 

positioned and secured at least 2 inches above 

the drain so that the water flow is directed into the 

drain, without splashing (Figure 1).

Figure 1. Proper Draining

Содержание SE-4200

Страница 1: ...WATER FILTRATION SYSTEM Model SE 4200 4400 Owner s Manual P N 1010852 Rev C 04 06 MANUFACTURING NUMBERS 9700501 9700505 9700508 9700512 ...

Страница 2: ...ease read the full text of the Limited Warranty in this manual If the unit arrives damaged contact the carrier imme diately and file a damage claim with them Save all packing materials when filing a claim Freight damage claims are the responsibility of the purchaser and are not covered under warranty The warranty does not extend to Damages caused in shipment or damage as result of improper use Ins...

Страница 3: ...rly grounded cord connector Do not attempt to defeat the grounded connector Install or locate the equipment only for its intend ed use as described in this manual Do not use corrosive chemicals in this equipment Do not operate this equipment if it has a dam aged cord or plug if it is not working properly or if it has been damaged or dropped This equipment should be serviced by qualified personnel ...

Страница 4: ...TIONS COULD RESULT IN SERIOUS INJURY OR DEATH Electrical ground is required on this appli ance Do not modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician Do not use an extension cord with this appliance Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded If the supply cord is d...

Страница 5: ...appliance is properly grounded Model Mfg Voltage Watts Amps Hertz SE 4200 9700501 9700505 120 150 1 25 50 60 SE 4400 9700508 9700512 230 150 75 50 60 Operating Specifications Operating Weight Unit A Width inches B Depth inches C Height inches Operating Weight w water lbs SE 4200 12 14 49 75 93 SE 4400 12 14 69 75 127 NOTE See Dimensions drawing on the next page Max Operating Pressure 7 bar 100 psi...

Страница 6: ...SE 4200 4400 WATER FILTRATION SYSTEM 6 P N 1010852 Rev C 04 06 Dimensions SPECIFICATIONS continued A C B Control Box Drain Permeate use water Inlet ...

Страница 7: ...n label Make sure that the plug on the power cord from the system and the outlet match For proper operation of the system and to ensure the highest quality of water from the sys tem make sure that the system is not connected to a switched electrical outlet An ABC type fuse 6 Amp 250 VAC is located inside the control box PLUMBING NOTE This unit is designed to use tap water not to exceed 104º F 40º ...

Страница 8: ...t quality and safest water it is recommended that a check valve to prevent backflow be installed in the water line after the permeate connec tion This will help prevent possible contamination of the filter system due to other equipment downstream The check valve not supplied should be mounted close to the system outlet and sized properly for the plumbing line Check with local codes for the proper ...

Страница 9: ...troller features following the steps within the Operation section of this manual CAUTION Be careful when handling bleach Follow all warn ings and precautions on the bleach packaging Do not mix Bleach with any other cleansers or sanitizers FLUSHING AND STARTING THE SYSTEM To ensure that the highest quality water is produced from the system the plumbing leading from the filter system must be flushed...

Страница 10: ...shing cycle and in STOP MODE NOTE Both the Filtration and Backwash cycles can be completely automated through the Control Panel See the Programming section within this manual Control Button Function FLUSH Performs a QUICK FLUSH operation when actuated during FILTER MODE or STOP MODE RUN Initializes and starts an internal timer for the automatic flushing of the system and puts the system into FILTE...

Страница 11: ...e SET DATE message Using the Up and Down arrow buttons enter the correct date in mm dd yy format After each entry press the Enter button For example for June set the month as 06 and then press the Enter button Set the date and year in this same manner 5 The system then displays the SET TIME message Using the Up and Down arrow buttons enter the correct hour in hh format and press the Enter but ton ...

Страница 12: ...utton to return to the FILTER MODE display SET FLUSH CYCLE MODE 1 From the FILTER MODE display press the Stop button The system switches to STOP MODE and displays the STOP MODE display 2 Press the Menu button 3 Using the Up and Down arrow buttons scroll from SET PASSWORD to SET FLUSH CYCLE Press the Enter button 4 The system displays the ACTIVATE FLUSH BY display Accept the default value of automa...

Страница 13: ...should be fine for most locations Press the Enter but ton to accept the change or to accept the default value if a change is not made 12 The system displays the SET FLUSH CYCLE dis play If you need to correct any settings press enter and make the desired changes If changes are not necessary press the Menu button to return to the STOP MODE display 13 Press the Run button to return to FILTER MODE RE...

Страница 14: ...acturer for instructions on using this function g The system then returns to the SET LANGUAGE display Press the Enter button to return to the SET PASSWORD display Then press the Menu button to return to STOP MODE Press the Run Button to return to FILTER MODE NOTE The REVIEW HISTORY mode displays infor mation about the most recent operation first 5 When finished reviewing history press the Enter bu...

Страница 15: ...rotected 1 Press the Stop Button The system will display the STOP MODE display 2 Press the Menu Button The system will display the ENTER PASSWORD display 3 Use the Up and Down arrow buttons to enter the first character of your password and then press the Enter button Repeat until the password has been selected and press the Enter button The system displays the SET PASSWORD display You may now scro...

Страница 16: ...End Caps 4 Disconnect the Permeate Port connection 5 Unscrew the cartridge End Caps from the car tridge slide the caps past the cartridge ends and remove the old cartridge from the system 6 Inset the new cartridge into the system 7 Attach the Permeate Port connection to the new cartridge 8 Inspect the O rings to make sure they are clean and are not splitting or cut For all O rings make sure they a...

Страница 17: ... increase the flush duration Drain valve s stuck open Replace rebuild valve s Low inlet water pressure Boost pressure replace pipes Water tastes bad Storage Shipping solution not complete ly flushed out Flush system longer Biological growth in pipes Sanitize plumbing Water conditions have changed Consider installing a taste and odor filter Broken Capillary in cartridge Replace cartridge Flush runs...

Страница 18: ...ght Tighten with strap wrench if necessary O rings not lubricated Lubricate O rings with food grade lubricant O rings split cut or twisted Replace O rings Water leaks from system fitting or connection Not enough pipe thread sealant used Redo fitting with proper amount of sealant Fitting loose or broken Retighten or replace fitting TROUBLESHOOTING continued ...

Страница 19: ...FILTRATION SYSTEM 19 P N 1010852 Rev C 04 06 REPLACEMENT PARTS SE 4200 4400 See Inset A 1 2 5 8 9 10 11 15 12 13 14 16 17 18 20 22 23 25 26 28 29 30 32 31 33 34 35 37 36 38 39 40 41 42 43 45 Inset A 47 65 21 47a 47 48 22a ...

Страница 20: ...7 4400 Cartridge Replacement Kit 1 31 2190130 Tee 3 4 Npt 6 32 2190132 Nipple 3 4 Npt X 5 Lg 2 33 2190139 Adaptor 1 1 2 To 3 4 Npt SE 4400 2 2190131 Adaptor 1 1 4 to 3 4 NPT SE 4200 2 34 2190141 Union Adaptor 3 4 2 35 2190124 Nipple 3 4 Npt 6 36 0504007 Clamp Permeate 1 37 2190126 90 Elbow 3 4 Npt 2 38 0504006 Bracket Permeate 1 39 4060304 Terminal Block 3 pole 1 40 0700634 Power Cord intl harmoni...

Страница 21: ...SE 4200 4400 WATER FILTRATION SYSTEM 21 P N 1010852 Rev C 04 06 WIRING DIAGRAM ...

Страница 22: ...SE 4200 4400 WATER FILTRATION SYSTEM 22 P N 1010852 Rev C 04 06 NOTES ...

Страница 23: ...SE 4200 4400 WATER FILTRATION SYSTEM 23 P N 1010852 Rev C 04 06 NOTES ...

Страница 24: ...on Technologies reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge 3 If shipment is damaged in transit the purchaser should make a claim directly upon the carrier Careful inspection should ...

Отзывы: