MIRACLE STEAMER
7
P/N 1010699 Rev. B
A.J. Antunes & Co.
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other applica-
ble codes.
WARNING
ELECTRICAL SHOCK HAZARD.
FAILURE TO FOLLOW THE INSTRUCTIONS IN
THIS MANUAL COULD RESULT IN SERIOUS
INJURY OR DEATH.
•
Electrical ground is required on this appliance.
•
Do not modify the power supply cord plug. If it
does not fit the outlet, have a proper outlet
installed by a qualified electrician.
•
Do not use an extension cord with this appli-
ance.
•
The unit should be grounded according to
local electrical codes to prevent the possibility
of electrical shock. It requires a grounded
receptacle with separate electrical lines, pro-
tected by fuses or circuit breaker of the proper
rating.
•
Check with a qualified electrician if you are in
doubt as to whether the appliance is properly
grounded.
PLUMBING
NOTE:
Miracle Steamer models are designed to use
cold tap water. Distilled water may be used to reduce
mineral deposit build-up and reduce maintenance
costs.
CAUTION
This equipment is to be installed to comply with
the basic plumbing code of the Building Officials
and Code Administrators, Inc. (BOCA) and the
Food Service Sanitation Manual of the Food and
Drug Administration (FDA).
REA
DY
Figure 2. Filling Water Tank–MS-150/155
Filter
Sliding Cover
READ
Y
ADD
WA
TER
Figure 3. Filling Water Tank–MS-355
Indicator Light (Low water)
Model MS-150/155 & MS-355
The MS-150/155 & MS-355 models have a self-con-
tained water supply and is portable. To fill the self-con-
tained water tank:
1.
MS-150/155:
Open the sliding tank cover on top
of the unit (Figure 2).
NOTE:
Make sure filter inside tank is installed
properly.
MS-355:
Open the sliding tank drawer on the side
of the unit (Figure 3).
2. Pour in cold tap water. The tank will hold approx-
imately 3 quarts (2.81 liters).
3. Close the water tank.
CAUTION