allows two way serial data to be sent/received if the ANT-4000E is paired up with an
ANT-4000D decoder unit. 3.3V data may be sent bi-directionally for control and command
applications. Serial data is sent as is subject to the serial port configurations (See System
setup- Serial Ports)
#
Serial Data Tx
#
Serail Data Rx
#
+3.3V DC
#
Earth
6. Installation- Powering Up & LED Status
Connect the 12V power converter to 110/240 V AC supply with the power lead provided.
Connect the 12V connector into the front panel of the ANT-4000E marked 12V DC Input.
1) Observe ALL LEDs are illuminated and flashing momentarily, this is to check all LEDs are working
2) LED1: This indicates if 12V DC power is connected
ON= Power On, OFF =Power OFF, Flashing= test mode on power up
3) LED2 : Booting Status of the onboard CPU
Flashing= Booting , On= Booted (LED3/4/5 will flash )
4) LED3: Client Connected
Flashing: No Client connected (decoder) , On= Client decoder Connected
5) LED4: Video Stream Data:
On= Video data is streaming, Flashing = Streaming is Off.
6) LED5: Video Input Connected
On= Video is connected to the selected input and identified as valid ,flashing= No Video
If the Encoder is working correctly in a typical system and connected to decoder and is streaming video
then ALL LEDs will be ON.