![ANTIFERENCE HDMI0102SCAT Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/antiference/hdmi0102scat/hdmi0102scat_user-manual_2947891007.webp)
Connection instruction:
1. Connect the HDMI signal source device to the HDMI input port on the main
splitter unit.
2. Connect the IR blaster to EXTENDER IR OUT and position in front of the
source device in the correct location to enable control.
3. Connect the CAT6 output cables to be fed to the remote location(s) to the
RJ45 output ports.
4. Connect the CAT6 cable into the RJ45 port on the RX and connect an HDMI
cable between the RX and TV set in the remote location.
5. Connect the IR RX sensor to the RX box and position on the front of the TV
where the remote control can communicate with it.
6. Insert the power supply to the main splitter unit (Power’s signal light is red
on start up, when there is signal input then the power light will turn blue)
EDID Setting
1. HDMI source device reads the EDID information from the splitter and then
outputs the relative HDMI signal format.
2. There are 8 in-built EDID status’, and they may be selected by the EDID
switch on the main splitter unit.
Details of the EDID settings are in the table below;
SW1
SW2
SW3
EDID Mode
0
0
0
720P@50Hz @CH
1
0
0
720P@50Hz 7.1CH
0
1
0
1080i@60Hz 2CH
1
1
0
1080i@60Hz 7.1CH
0
0
1
1080P@60 2CH
1
0
1
1080P@60Hz 7.1CH
0
1
1
Read Loop-out (if not connect the loop-out show default)
1
1
1
Default 720P@50Hz 2CH