DISPLAY

O P E R A T I O N  

Before plugging in the CD 1, check to see that the unit is

configured for the correct AC line voltage for country of use.

The operating AC line voltage is indicated on the side of the

shipping box. If the CD 1 is set incorrectly for the country in

which it is to be operated, contact the dealer or distributor

in your area. If the unit is configured properly, continue with

operation.

Connect the Detachable Power Cord to the CD 1 chassis

rear (see Figure 6). Plug your CD 1 into the AC power

source.  You may now turn on the CD 1.

Note: Never unplug your CD 1 during operation. First

shut off your Power Amplifier, then stop the CD 1 by

depressing the Stop button (D), and remove AC

power by pressing and releasing Power Switch (G).

It is recommended that you shut OFF the main power via the Power

Switch (G) when not listening.

T R O U B L E S H O O T I N G

If at any time the CD 1 fails to work properly, consult this checklist:

1. Check that the AC Detachable Power Cord is plugged into

the CD 1 Detachable Power Cord Socket (H) and is connected

to a live source of AC power. For instance, if using a power bar,

check that the bar is turned on.

2. Ensure that all Input and Output connections are secure for 

a proper electrical contact.

3. DISCONNECT THE AC POWER CORD, wait 5 minutes,

remove the chassis covers from the CD 1 and check that:

• A “fast-blo” fuse, with a rating of 1 Amp/250 V (0.5 Amp/250

V for European and Asian versions), is installed on the circuit

board under the soft plastic cover (see figure 2).

• The AC power fuse is intact and has not blown. If the fuse has

blown, the thin metal conductor will have melted and the glass

may appear “smoked”. If the fuse has blown, replace with a

fuse of the same rating (1 Amp/250V fast-blo for 100 to 120 volt

countries and .5 Amp/250V fast-blo for 220 to 240 volt 

countries). (See Figure 2.)

NOTE: Under no circumstances should you replace the AC

power fuse with one of a higher current rating! Doing so may

cause damage to the CD 1 and will also void the warranty. In

addition, your continued protection from risk of fire or shock

would be seriously compromised.

• Ensure the tube is plugged firmly into its socket.

4. Be sure the rest of the system is functioning properly (i.e.

preamps, power amplifiers, cables and connections, etc.).

5. With tubes, fuses, covers and power cords in place, check

that the Display is lit. If all of the above troubleshooting steps

have been followed and the Display is not lit, contact your dealer

or distributor for assistance.

Figure 6 - Alignment of the AC power connector and detachable cord.

WARNING-DISCONNECT THE AC

DETACHABLE POWER CORD FROM THE

CD 1 AND WAIT 5 MINUTES BEFORE

REMOVING COVER, TUBES OR FUSE.

DANGER:

INVISIBLE LASER RADIATION 

POSSIBLE WHEN THE TOP COVER

IS REMOVED. AVOID DIRECT 

EXPOSURE TO THE LASER BEAM.

Figure 3. CD 1 Front

Содержание CD 1

Страница 1: ...3 T E C H N I C A L S P E C I F I C A T I O N S INTRINSIC JITTER 140ps RMS measured over a bandwidth of 10Hz 40kHz POWER SUPPLY EI Laminate power transformer featuring 9 stages of power supply regulation TRANSPORT MECHANISM Sony 6 pack Vertical Changer Plays 5 discs and 3 5 discs 3 5 discs single play only HDCD FILTER DECODER Pacific Microsonics PMD 100 D A CONVERTER Dual Burr Brown PCM 1702P TUBE...

Страница 2: ... or neglect or in being transported or the defect is due to the product being tampered with modified or repaired by anyone other than Sonic Frontiers International or an authorized Sonic Frontiers International repair service center Warranty does not cover normal maintenance Sonic Frontiers International shall not be responsible in any way for consequential or indirect damages or liabilities resul...

Страница 3: ...Use Periods The power cord of this product should be unplugged from the outlet when left unused for an extended period of time 8 Do not remove the CD 1 cover while the unit is on or connected to an AC power source Cover screws could fall through the ventilation slots and cause electrical damage to the CD 1 The player may leak invisible laser radiation if the cover is removed Avoid direct exposure ...

Страница 4: ... the chassis covers from the CD 1 and check that A fast blo fuse with a rating of 1 Amp 250 V 0 5 Amp 250 V for European and Asian versions is installed on the circuit board under the soft plastic cover see figure 2 The AC power fuse is intact and has not blown If the fuse has blown the thin metal conductor will have melted and the glass may appear smoked If the fuse has blown replace with a fuse ...

Страница 5: ... processor with switched AC outlets it may be convenient to leave the POWER button in the ON position Then you may switch the power ON and OFF to the CD 1 with the preamplifier or surround sound processors remote control Ask your Anthem Authorized Dealer for advice about this if this unfamiliar to you C O N T R O L F U N C T I O N S R E F E R T O F I G U R E 3 O TRACK FORWARD AND REVERSE BUTTONS T...

Страница 6: ...IONS The rear panel of the CD 1 has the analog output connections These are RCA jacks and should be connected to the CD or AUX input of your stereo integrated amp receiver or preamplifier Please observe the correct Left and Right channel connections for optimum enjoyment of your stereo L I R INPUT An infrared extension unit may be connected to this 3 5 mm phono connector to allow control access vi...

Страница 7: ... N T A R I O C A N A D A L 5 L 5 Y 7 T E L 9 0 5 8 2 8 4 5 7 5 F A X 9 0 5 8 2 8 4 5 8 5 S o n i c F r o n t i e r s c a n b e r e a c h e d 9 0 0 a m t o 6 0 0 p m E S T o r 2 4 h o u r s a d a y b y f a c s i m i l e E M a i l S F I s o n i c f r o n t i e r s c o m W e b S i t e h t t p w w w s o n i c f r o n t i e r s c o m C D 1 O P E R A T I N G M A N U A L ...