Operating Manual – Digital Frequency Converter
Page 12 of 14
09/99 R0048GB.doc
Antriebstechnik GmbH
5.6 Parameterisation
The frequency converter is parameterised using the ANTEK monitor program “FUxAE” and
a standard RS232 interface. The interface parameters are set automatically.
The parameters can be sent / received using the following commands:
[CTRL+U]
Freq. converter
Î
PC
[CTRL+D]
PC
Î
Freq. converter
Parameters
Mode
Steller: Frequency converter sets frequency
Regler: Frequency conversion combined with r.p.m. regulation
U-Netz
Mains input voltage
Range: 0 ... 480 VAC
Caution!
Re-check parameters after changing mains input voltage.
Boost
Compensation for winding resistance at lower output
frequencies.
Range: 0 ... 100 VAC
Caution!
The motor will become unusually warm if set too high. Check
motor current.
Hoch-, Rücklauframpe
Ramp times from 0 to maximum r.p.m.
Range: 0,1 ... 20,0 sec
f-max
Maximum frequency at maximum nominal value setting
Range: 0 ... 160 Hz
Eckfrequenz
Frequency where max. output voltage is reached
Range: 0 ... 160 Hz
Offset
Offset adjustment of analogue nominal r.p.m. input
Range: -2750 ... 2750 mV