Operating Manual – Digital Frequency Converter 

Page 11 of 14

09/99   R0048GB.doc

       Antriebstechnik GmbH

5.5 Program installation

5.5.1  System requirements

“Windows 95” or “Windows 98” must be correctly installed on the computer in order to use
the ANTEK Monitor program. Additionally, the following minimum requirements must be
fulfilled:

  8 MB available memory

  700 KB available disk-space

The program will not run under “Windows 3.11“. If needed, please request the Win3.11-
Version from ANTEK GmbH.

5.5.2 Installation

To start Set-up:

1)  Start Windows (if not already active).

2)  Insert ANTEK Monitor program Disk 1 in disk-drive A.

3)  Using “Start“, “Run“, “Search“, click on “Set-up“ on drive A and confirm with

“Open“.

4)  Click “OK“ to start Installation. The Set-up-Menu recommends the folder

“ANTEK”, confirm with “Beenden“.

5)  Set-up installs the program in the folder “ANTEK” and adds the program

“Monitorprogramm FUxAE“ to the program menu.

6)  Double-click “Monitorprogramm FUxAE“ in the program menu to start the

monitor program.

5.5.3 De-installation

A “Deinstaller“ is also included in the program menu to remove the program files.

5.5.4  Serial Interface

Communication between the monitor program and the frequency converter is sent over a
standard RS232 interface cable.  This cable should be kept as short as possible.

RS232
9-pol. D-SUB-Buchse
Datenleitung RXD, TXD nicht
gekreuzt

Regelgerät

RS232

Achtung !
Bei 25-pol. PC-Schnittstelle ist Pin 7=GND

AT

RXD

TXD

GND

RXD

TXD

GND

2

3

5

2

3

5

Содержание FU 3 AE-03

Страница 1: ...ncy Converter FU 3 AE 03 Digital Frequency converter for stepless speed control of 3 phase a c motors up to 1 1 kW 1 Important Pre operation information 2 2 Brief description 5 3 Specification FU 3 AE...

Страница 2: ...equipment must read the unit handbook thoroughly Ensure that the voltage is not dangerous before touching electrical contacts The user must use independent monitoring units in order to ensure that a...

Страница 3: ...ation in card racks The unit must be installed vertically The air flow of the unit must not be obstructed The air inlet and outlet must be kept clear Important information regarding protective earthin...

Страница 4: ...from signal lines are to be laid two way source and target large area and well conducting to a ground 1 In case of poor potential equalization between shielded connections an additional balancing net...

Страница 5: ...rack mount with 3 standard european boards 160 mm Integrated switching power supply Advantages Compact and space saving type as 3HE 19 insert Operation with industry standard motors min Inductivity 2m...

Страница 6: ...ons 100 Efficiency at nominal load ca 95 Power loss at no load ca 20 W Power loss nominal load ca 60 W Clock frequency of output transformer ca 3 9 kHz Digital Control inputs Reglerfreigabe Reset Faul...

Страница 7: ...1 8 PE X1 11 L1 Supply voltage connection 3x 400 VAC 10 480 VAC 6 X1 14 L2 50 60 Hz X1 17 L3 External fuse 3x 10 A Z characteristics Wire behind the main filter must always be shielded X1 20 UZK Inter...

Страница 8: ...n speed set point 0 10 VDC Ri 10 k reference GND X2 22a Warning This connection always must be shielded X2 18a Tacho Connection for pulse generator Warning This connection always must be shielded Auxi...

Страница 9: ...2 3 X1 L1 L2 L3 M ain connectu ib 3x 400 VAC 1 0 480 VAC 6 5 0 60 H z Pre fuse ABB S283 Z10 11 14 17 X1 26 29 32 X1 M 3 DT SE 5 X1 2 24VD C Voltage supply X2 2a X2 4a X2 1 0a X2 1 2a X2 1 8a R ight L...

Страница 10: ...has detected the r p m difference Threshold ca 1 5 from n max Relay contacts opened X2 26a and X2 28a LEFT YE Indicates Enable left Pin X2 2a RIGHT YE Indicates Enable right Pin X2 4a 5 3 Measuring po...

Страница 11: ...Start Run Search click on Set up on drive A and confirm with Open 4 Click OK to start Installation The Set up Menu recommends the folder ANTEK confirm with Beenden 5 Set up installs the program in the...

Страница 12: ...s frequency Regler Frequency conversion combined with r p m regulation U Netz Mains input voltage Range 0 480 VAC Caution Re check parameters after changing mains input voltage Boost Compensation for...

Страница 13: ...requency Hz p number of pole pairs z number of increments resolution P Anteil I Anteil Regulating behaviour Range 0 00 10 Achtung Improper regulator parameters can cause the drive to oscillate Schwell...

Страница 14: ...voltage Check mains voltage Check circuit breakers and fuses Cable fault Check motor phases Thermo switch in Motor has tripped Allow motor to cool Reduce motor load Check cooling Boost setting in Ste...

Отзывы: