5
Note regarding fan speed controllers:
The minimum voltage to start the fan is
5V. We recommend our users set the fan speed to High if the fan will be con-
nected to a fan control device or to the Fan-Only connector found on some Antec
power supplies. A fan-control device regulates the fan speed by varying the volt-
age to it. The voltage may start as low as 4.5V to 5V. Connecting a TriCool™ set
on Medium or Low to a fan-control device may result in the fan not being able
to start. The already lowered voltage from the fan control device will be further
reduced by the TriCool™ circuitry below 5V.
Specifications:
Size:
120mm x 120mm x 25.4mm
Rated Voltage:
DC 12V
Operating Voltage:
10.2V ~ 13.8V
Speed
Input
Current
Air Flow
Static
Pressure
Acoustical
Noise
Input
Power
High
2000 RPM
0.24A
(Max.)
2.24 m³ / min
(79 CFM)
2.54 mm-H2O
(0.10 inch-H2O)
30 dBA
2.9 W
Medium
1600 RPM
0.2A
1.59 m³ / min
(56 CFM)
1.53 mm-H2O
(0.06 inch-H2O)
28 dBA
2.4 W
Low
1200 RPM
0.13A
1.1 m³ / min
(39 CFM)
0.92 mm-H2O
(0.04 inch-H2O)
25 dBA
1.6 W
Содержание NSK2400