Warning 

 

 

 

Unpacking Instructions 

Immediately upon receiving this product, carefully unpack the carton and check the contents to ensure 

that all parts are present and have been received in good condition. Notify the dealer immediately and 

retain packing material for inspection if any parts appear damaged from shipping or the carton itself 

shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be 

returned to the factory, it is important that the fixture be returned in the original factory box and packing. 

 

Your shipment includes: 

 

Antari IP-1500 (cable length: 1,5 m) 

 

1 x PU pipe  

 

Wireless remote control 

 

1 x safety eye 

 

2 x adjustment screw, 

 

1 x mounting bracket 

 

User manual 

 

 

 

 

 

Safety Instructions 

Every person involved with the installation, operation and maintenance of this device has to: 

 

be qualified 

 

follow the instructions of this manual 

 

 

 

 

Before your initial start-up, please make sure that there is no damage caused by transportation. Should 

there be any, consult your dealer and do not the device. 

 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 

follow the safety instructions and warning notes written in this manual. 

Please consider that damages caused by manual modifications to the device are not subject to 

warranty. 

This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 

 

 

  

 

 

   

 

Содержание IP-1500

Страница 1: ...Antari IP 1500 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 60899 MANUAL ENGLISH...

Страница 2: ...Controllers DMX Control 9 Data Cabling 10 Control Panel 10 Control Mode 10 DMX Addressing 10 Menu Overview 11 Start up settings 11 Main Menu Options 12 1 Control modes 12 2 Interval settings Timer mo...

Страница 3: ...cable length 1 5 m 1 x PU pipe Wireless remote control 1 x safety eye 2 x adjustment screw 1 x mounting bracket User manual Safety Instructions Every person involved with the installation operation a...

Страница 4: ...ut sleeve in place if the machine is to be used in the presence of children Always keep the fog output at least 50 cm away from contact with anything while in operation Always disconnect power from th...

Страница 5: ...ied out by an authorized dealer Procedure If the fog machine is lowered from the ceiling or high joints professional trussing systems have to be used Use a clamp to mount the fog machine with the moun...

Страница 6: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Страница 7: ...0 cu ft min Fluid consumption 11L min Power connection Schuko DMX control 1 channel 5 pin DMX signal connector IN Included wireless remote control Warm up time 10 min IP rating IP63 Dimensions 460 x 2...

Страница 8: ...de Fig 02 05 Schuko power cable 06 Fog fluid IN 07 Circuit breaker 08 5 pin DMX signal connector IN 09 Wireless receiver 10 Safety eye included 11 LCD display menu buttons Remote control 12 A button 1...

Страница 9: ...in horizontal position Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Before plugging...

Страница 10: ...ion about Timer mode and Continuous mode Multiple Controllers DMX Control 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety...

Страница 11: ...Ordercode FL0975 0 75 m FL09150 1 5 m FL093 3 m FL096 6 m FL0910 10 m FL0915 15 m FL0920 20 m DAP Audio DMX adapter 3 pin 5 pin Ordercode FLA30 Control Panel The Antari IP 1500 can be operated with a...

Страница 12: ...ivate wireless control 05 After 15 seconds the display will show Now it is not possible to activate any remote controls anymore 06 The display will now show The warm up process will take up to 10 minu...

Страница 13: ...sen the desired control mode the device will start fog output using the settings below 04 Press the button to stop output 2 Interval settings Timer mode With this menu you can set the intervals betwee...

Страница 14: ...ngs With this menu you can set whether the device reacts to the remote control Please see page 14 for more information on the remote control operations 01 Press the button until the display shows 02 P...

Страница 15: ...is switched ON the device will shut down if it stops receiving DMX signal When the device receives DMX signal it will resume operation Remote control Fig 08 Make sure that wireless control is active P...

Страница 16: ...s free of clogs 02 Remove all fog liquid from machine Add cleaning solution to tank Plug unit in 03 Run unit in a well ventilated area until tank is empty 04 Refill with fog liquid Performance Note Fo...

Страница 17: ...ing bracket included Housing Die cast aluminum powder coat finish Power connection Schuko Onboard LCD display for easy setup DMX channels 1 channel DMX control via DMX light controller Remote control...

Страница 18: ...Ordercode 60899 Antari IP 1500 Dimensions 17...

Страница 19: ...Ordercode 60899 Antari IP 1500 18...

Страница 20: ...2015 Antari...

Отзывы: