Ordercode: 60899
Antari IP-1500
DMX Channels
1 channel
Channel 1 – Functions
0-5
Not functional
6-249
Gradual adjustment output volume (5-95%)
250-255
Maximum output (100%)
Maintenance
The Antari IP-1500 requires almost no maintenance. However, you should keep the unit clean. Disconnect
the mains power supply and then wipe the cover with a damp cloth. Wipe the front panel with a damp
cloth. Do not use alcohol or solvents. Do not immerse in liquid.
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth.
Make sure connections are thoroughly dry before linking equipment or supplying electric power.
Do not allow the fog liquid to become contaminated. Always replace the caps on the fog liquid
container and the fog machine liquid tank immediately after filling.
After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of
80% distilled water / 20% white vinegar through the system. Repeat this 2-4 times.
When cleaning, use only a clean, lint-free soft cloth. An effective cleaning regimen is as follows:
01)
While unit is unplugged and cool, clean out debris with vinegar and a pipe cleaner, making sure that
the hole is free of clogs.
02)
Remove all fog liquid from machine. Add cleaning solution to tank. Plug unit in.
03)
Run unit in a well-ventilated area until tank is empty.
04)
Refill with fog liquid.
Performance
Note:
Fog machines may sputter small amounts of fog occasionally during operation and for a minute or so
after being turned off.
Troubleshooting
This troubleshooting guide is meant to help solve simple problems.
Always monitor tank liquid level as you are blowing fog. Running a fog machine with no liquid can
permanently damage the unit.
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit
operates properly, do not carry out following steps.
If the fog machine does not operate properly, refer servicing to a technician.
01)
If you experience low output, mechanical pump noises other than the usual normal operating pump
noise, or no output at all, unplug immediately.
02)
Check liquid level, remote connection and power from the wall.
03)
If all of the above appears to be O.K., plug the unit in again.
04)
If fog does not come out after holding the remote button down for 30 seconds, check the hose
attached to the tank to make sure there is liquid going through the hose.
05)
If you are unable to determine the cause of the problem, do not simply continue pushing the remote
button, as this may damage the unit.
06)
Return the machine to your Antari dealer.