9
Fluid
Only use Antari FLG water-based liquid for the F-4 Fazer. The machine is tested and
calibrated with this liquid to get the best output performance. Warranty will be void if any
other type of liquid is used, improper use of liquid may lead to machine failure and
malfunction.
Service and Maintenance
․
Do not allow the machine to become contaminated.
․
Remove dust from air vents with air compressor, vacuum or a soft brush.
․
Only use a damp cloth to clean the casing.
․
Before storing run distilled water through the system to help avoid condensing the
pump or heater.
․
It is recommended to run the machine on a monthly basis in order to achieve best
performance and output condition.
․
Excessive dust, liquid and dirt built up will degrade performance and cause
overheating.
Replacing the Fuse
Disconnect AC power before replacing fuse. Only replace fuse with same type
and rating.
Step 1:
Disconnect power cord from supply.
Step 2:
Use a flat-head screwdriver to release fuse holder.
Step 3:
Replace fuse with exact same type and rating as indicated below.
Step 4:
Reinsert fuse holder.
Fuse
110
– 120V = 15A 250V
220
– 240V = 7A 250V
Содержание F-4 Fazer
Страница 1: ...F 4 Fazer User Manual English Fran ais Deutsch 2016 Antari Lighting and Effects Ltd...
Страница 2: ......
Страница 29: ...29...
Страница 30: ...30...
Страница 31: ...31...
Страница 32: ...C08F40000...