Antari S-500 Snow Machine 

Extension Hose Installation 

It is possible to extend the default output hose with the optional 10-meter ST-10 extension hose (

80389

). 

 

 

The total length of the output hose must not exceed 20 m. 
It is forbidden to install more than one ST-10 extension hose. 

 
01)

 

Release the safety locks and separate the output nozzle (09) from the output hose (08)

02)

 

Disconnect the snow liquid hose located inside. See Fig. 08.  

 

 

Fig. 08 

 
03)

 

Connect the snow liquid hose inside the ST-10 extension hose (red) to the output nozzle (09). See 
Fig. 09. 

04)

 

Connect the snow liquid hose on the other end of the ST-10 extension hose to the output hose (08)
See Fig. 09. 

 

 

Fig. 09 

 
05)

 

Connect the output nozzle (09) to the ST-10 extension hose and secure the safety locks. Connect the 
other end of the ST-10 extension hose to the output hose (08) and secure the safety locks. See Fig. 10. 

 

 

Fig. 10 

 
 

 

Содержание 80378

Страница 1: ...Antari S 500 Snow Machine V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 80378 MANUAL ENGLISH ...

Страница 2: ...xtures DMX Control 13 Fixture Linking 14 Data Cabling 14 Control Panel 15 Control Mode 15 DMX Addressing 15 Menu Overview 16 Main Menu Options 17 1 Timer Interval 18 2 Timer Duration 18 3 Timer Output 18 4 Volume Output 18 5 Fan Speed 18 6 DMX Address 18 7 Wireless DMX 18 8 Wireless DMX Reset 18 9 Wireless Transmitter 19 10 Run Last Setting 19 Manual Mode 19 1 Timer Mode 19 2 Volume Mode 19 Remote...

Страница 3: ...ry it is important that the fixture be returned in the original factory box and packing Your shipment includes Antari S 500 Snow Machine Neutrik powerCON to Schuko power cable 1 7 m 1 x tank hose User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before the initial start up ...

Страница 4: ...mmended by your dealer ordercodes 60588 60589 and 80359 Other snow liquids may cause poor effect Avoid flames and do not put close to flammable liquids or gases Always make sure there is sufficient liquid in the snow liquid tank Operating this unit without liquid can cause damage to the pump and the heater Always allow free air space of at least 50 cm around the unit for ventilation Make sure that...

Страница 5: ... non use completely disconnect from power source via breaker or by unplugging The relative humidity must not exceed 50 with an ambient temperature of 40 C If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void Any other operation may lead to dangers like short circuit burns electric shock crash etc We presume t...

Страница 6: ...estion proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visi...

Страница 7: ...Onboard LCD display control buttons Control modes Manual Timer Remote control Wireless remote control DMX 512 W DMX DMX mode 2 channels Color Black Housing Flight case Data connection 3 pin 5 pin XLR IN OUT 4 pin remote control connector IN Power connection Neutrik powerCON connector Blue IN IP rating IP20 Dimensions 592 x 551 x 640 mm LxWxH Weight 35 kg Optional accessories 60587 Antari SC 3 remo...

Страница 8: ...0 Snow Machine Front Fig 01 01 Snow liquid tank 20 L 02 Tank hose 03 Snow liquid input 04 LCD display control buttons 05 Wireless receiver housing cover 06 Circuit breaker 07 Power switch ON OFF 08 Output hose 10 m 09 Output nozzle ...

Страница 9: ...op Fig 02 10 Neutrik powerCON power connector Blue IN 11 5 pin DMX signal connector OUT 12 3 pin DMX signal connector OUT 13 3 pin DMX signal connector IN 14 5 pin DMX signal connector IN 15 4 pin SC 3 remote control IN 16 Ground earth connection ...

Страница 10: ...manual and from local authorities Precautions for operation Using a damaged or an improperly installed machine can lead to death serious injury or property damage Always inspect the machine thoroughly before operation Missing or obscured safety symbols on the machine can cause unawareness which in turn can lead to death serious injury or property damage Make sure all safety symbols are correctly i...

Страница 11: ... and attach it firmly to the snow liquid input 03 See Fig 04 03 Replace the cap and tighten it around the snow liquid input 03 See Fig 05 Fig 03 Fig 04 Fig 05 04 Attach the other end of the tank hose to the fog liquid tank cap See Fig 06 Fig 06 Fig 07 05 To uninstall the tank hose pull on the quick lock located on the snow liquid tank cap and remove the tank hose See Fig 07 ...

Страница 12: ...the output nozzle 09 from the output hose 08 02 Disconnect the snow liquid hose located inside See Fig 08 Fig 08 03 Connect the snow liquid hose inside the ST 10 extension hose red to the output nozzle 09 See Fig 09 04 Connect the snow liquid hose on the other end of the ST 10 extension hose to the output hose 08 See Fig 09 Fig 09 05 Connect the output nozzle 09 to the ST 10 extension hose and sec...

Страница 13: ... rigging derigging or servicing the device Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Improper installation can cause serious injuries and or damage of property Output Nozzle Angle Adjustment Fig 12 01 Loosen the adjustment scre...

Страница 14: ...des Multiple S 500 fixtures DMX Control 01 Leave at least 0 5 meter on all sides for air circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 Use a 3 pin 5 pin XLR cable to connect the S 500s and other devices 04 Link the units as shown in Fig 13 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repe...

Страница 15: ...your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X type data cable XLR M 3 pin XLR F 3 pin Ordercode FLX0175 0 75 m FLX0115...

Страница 16: ... the DMX addresses right Therefore the DMX address of the first S 500 should be 1 001 the DMX address of the second S 500 should be 1 2 3 003 the DMX address of the third S 500 should be 3 2 5 005 etc Please make sure that you do not have any overlapping channels in order to control each S 500 correctly If two or more S 500 fixtures are addressed similarly they will work similarly Controlling Afte...

Страница 17: ...16 Ordercode 80378 Antari S 500 Snow Machine Menu Overview ...

Страница 18: ...e software version voltage and frequency The current software version is 02 After a couple of seconds the display will show 03 Press the MENU button to enter the main menu 1 Timer Interval 2 Timer Duration 3 Timer Output 4 Volume Output 5 Fan Speed 6 DMX Address 7 Wireless DMX 8 Wireless DMX Reset 9 Wireless Transmitter 10 Run Last Setting ...

Страница 19: ...button to confirm The display will show READY TO SNOW 5 Fan Speed In this menu you can set the fan speed 01 Press the MENU button until the display shows FAN SPEED 02 Press the UP DOWN buttons to set the fan speed The adjustment range is 20 100 from slow to fast 03 Press the STOP button to confirm The display will show READY TO SNOW 6 DMX Address In this menu you can set the DMX address 01 In main...

Страница 20: ...TTING 02 Press the UP DOWN buttons to select ON OFF 03 Press the ENTER button to confirm The display will show READY TO STOP 04 If you selected ON upon power up the device will perform last action from before shutdown Manual Mode 1 Timer Mode In this menu you can set Timer mode 01 Set the interval and duration times See page 18 for more information 02 Set the timer output volume See page 18 for mo...

Страница 21: ...gh 03 Turn the FAN control to the left or right to set the fan speed The adjustment range is from low to high 04 Press the POWER button to activate the SC 3 remote control 05 Press the PRIMING button set the maximum pump output level Pressing this button will override the current setting of the VOLUME control Use this button in order to flush the system and remove air bubbles especially after refi...

Страница 22: ...can be purchased separately Contact your Antari dealer for more information In order to use the W2 wireless transmitter install the W2R wireless receiver first W2R Wireless Receiver Fig 16 01 Use a screwdriver to remove the 2 mounting screws and then remove the wireless receiver housing cover 05 Fig 17 02 Connect the W2R wireless receiver to the connector located in the housing Replace and tighten...

Страница 23: ...ransmitter on page 19 for more information Unlinking 01 Before start up of the S 500 press and hold down the DOWN button and then flick the power switch 07 to ON position The display will show 02 Press the DOWN button The display will show and shortly afterwards it will show Operation 01 In main menu press the MENU button until the display shows WIRELESS 02 Press the UP DOWN buttons to select ON 0...

Страница 24: ...y after adding the snow liquid to the tank Performance Note Snow machines develop condensation around the output nozzle Because this may result in moisture accumulation on the surface below the output nozzle consider this condensation when installing your machine Snow machines may occasionally sputter small amounts of snow during operation and or after being turned off Only use the recommended sno...

Страница 25: ...t operates properly do not carry out following steps If the S 500 does not operate properly refer servicing to a technician 01 If you experience low output or no output at all unplug immediately 02 Check the snow liquid level and the power from the wall 03 Check if the tank hose is properly attached to the snow liquid tank 04 Check the fuse See page 23 05 If all of the above appears to be O K plug...

Страница 26: ...es reset correctly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective device disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged ca...

Страница 27: ...ontrol Wireless remote control DMX 512 W DMX DMX mode 2 channels Color Black Housing Flight case Data connection 3 pin 5 pin XLR IN OUT 4 pin remote control connector IN Power connection Neutrik powerCON connector Blue IN IP rating IP20 Dimensions 592 x 551 x 640 mm LxWxH Weight 35 kg Max ambient temperature ta 40 C Minimum distance Minimum distance from surfaces 0 5 m Minimum distance from object...

Страница 28: ... 2020 Antari ...

Отзывы: