Antari 80374 Скачать руководство пользователя страница 4

 

  

 

 

   

 

Product code: 80374 

Antari AF-5E DMX Fan 

IMPORTANT

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Always hold the device by the transport handle. 

 

Never remove warning or informative labels from the device. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the fan. 

 

Never leave any cables lying around. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmer pack. 

 

Do not use the fan if any part is damaged or missing. 

 

Do not touch the fan blades, while operating the device. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Only operate the device after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always allow free air space of at least 50 cm around the device for ventilation. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

If text and/or icons are missing, damaged or illegible on the device, they should be replaced. 

 

Make sure that the available voltage is not higher than stated on the device. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If the fan is obviously damaged, it has to be replaced. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If the AF-5E fails to work properly, discontinue the use immediately. Pack the device securely 
(preferably in the original packing material), and return it to your Antari dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the 
device running unattended. 

 

Allow time to cool down, before cleaning or servicing. 

 

The user is responsible for correct positioning and operating of the AF-5E. The manufacturer will not 
accept liability for unsafe situations, accidents, damages caused by: 

 

the misuse or incorrect installation of this device. 

 

ignoring warnings or instructions as shown in this manual. 

 

using the AF-5E for purposes or in conditions other than specified in this manual. 

 

changes to the AF-5E. This includes the use of other than original spare parts. 

 

inadequate maintenance. 

 

the unauthorized removal of safety symbols, safety covers and/or guards. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Содержание 80374

Страница 1: ...Antari AF 5E DMX Fan V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 80374 MANUAL ENGLISH ...

Страница 2: ...ce 7 Front 7 Installation 8 Setup and Operation 8 Control Modes 8 One AF 5E Manual 8 Multiple AF 5Es DMX Control 8 Device Linking 9 Data Cabling 9 Control Mode 10 DMX Addressing 10 Main Menu Options 10 1 Manual Mode 10 2 DMX 512 Mode 11 DMX Channels 13 1 Channel 13 Maintenance 13 Troubleshooting 13 Fan Does Not Function 13 No Response to DMX 14 Product Specifications 15 Notes 16 ...

Страница 3: ...g Your shipment includes Antari AF 5E DMX Fan with a fixed Schuko power cable 1 6 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual Before the initial start up please make sure that there is no damage caused by transportation Should there be any consult your dealer and do...

Страница 4: ...are missing damaged or illegible on the device they should be replaced Make sure that the available voltage is not higher than stated on the device Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time If the external cable is damaged it has to be replaced by a qualified technician If the fan is obviously damaged it has to be replaced If de...

Страница 5: ... be dealt with This includes the correct use maintenance and repair of the AF 5E as described in this user manual The employees should be familiar with the use of devices through training and or experience Improper installation can cause serious injuries and or damage of property You endanger your own safety and the safety of others Antari excludes liability for unsafe situations accidents and dam...

Страница 6: ...roper installation can cause serious injuries and or damage of property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the dev...

Страница 7: ...hone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt...

Страница 8: ...modes Manual DMX 512 DMX mode 1 channel Color Black Housing Metal plastic Data connection 5 pin XLR IN OUT Power connection Fixed Schuko power cable 1 6 m IP rating IP20 Dimensions 550 x 466 x 575 mm LxWxH Weight 18 kg Front Fig 01 01 Air outlet 02 5 pin DMX signal connector OUT 03 Manual DMX LED indicator When the LED lights green you can operate the device with the fan speed selector 07 When the...

Страница 9: ... flat surface Leave at least 0 5 meter on all sides for air circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 When the AF 5E is not connected with a DMX cable it functions as a stand alone device 04 Please see 1 Manual Mode on page 10 for more information Multiple AF 5Es DMX Control 01 Place the AF 5E on a flat surface Leave at least 0 5 met...

Страница 10: ... own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Ordercode FL01150 1 5 m FL013 3 m FL016 6 m FL0110 10 m FL0115 15 m FL0120 20 m DAP Audio X type data cable XLR M 3 pin XLR F 3 pin Ordercode FLX0175 0 75 m FLX01150 1 ...

Страница 11: ...more AF 5E devices are addressed similarly they will work similarly Controlling After having addressed all AF 5E devices you may now start operating these via your lighting controller Note After switching on the AF 5E will automatically detect whether DMX 512 data is received or not If it does not the problem may be The XLR cable from the controller is not connected to the input of the AF 5E The c...

Страница 12: ...tal sum 31 Explanation Since each device has 1 channel each address advances by 1 value See Address Value above Once address values are determined add DMX DIP switch values to obtain the appropriate address DMX DIP Switches ON for each device Flip appropriate DMX DIP switches on each device Example 2 01 If you want to set a DMX address 133 you first have to find the number 133 in the DMX Address Q...

Страница 13: ...12 Product code 80374 Antari AF 5E DMX Fan DMX Address Quick Reference Chart ...

Страница 14: ... show any damages or material fatigue The AF 5E requires almost no maintenance However you should keep the device clean Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Do not use alcohol or solvents Please clean internal components once a year with a light brush and vacuum cleaner Keep connections clean Disconnect electric power and then wipe th...

Страница 15: ...on the link Devices reset correctly but some respond erratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective device disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or r...

Страница 16: ...al DMX 512 DMX mode 1 channel Color Black Housing Metal plastic Data connection 5 pin XLR IN OUT Power connection Fixed Schuko power cable 1 6 m IP rating IP20 Dimensions 550 x 466 x 575 mm LxWxH Weight 18 kg Max ambient temperature ta 40 C Minimum distance Minimum distance from surfaces 0 5 m Minimum distance from objects 0 5 m Design and product specifications are subject to change without prior...

Страница 17: ...16 Product code 80374 Antari AF 5E DMX Fan Notes ...

Страница 18: ...17 Product code 80374 Antari AF 5E DMX Fan ...

Страница 19: ...18 Product code 80374 Antari AF 5E DMX Fan ...

Страница 20: ... 2021 Antari ...

Отзывы: