ANTAIRA MSC-104B Скачать руководство пользователя страница 4

PCI Multi-port Serial Card

 

 

 

4

 

 

 

4.

 

S1~S4 Connector Pin Assignments 

The RS-422/485 signals are connected by a DB37 octopus 

cable to 4 DB9-male connectors, the DB9-male pin 

assignment as follows:   

 

 

 

 

 

 

 

 

   

 

Note: 

1. 

The drivers for Windows are shipped in the following folder 
(E:\IO\OXFORD\RS422_485) of the driver CD. 

The files are in ZIP 

format (e.g. V6515_RS422_485.ZIP). Please copy the file to your hard 
drive C: or what folder you want, unzip it before proceeding with your 
installations. We assumed you copy the file to your hard drive C: root 
directory, and the unzipped folder is V6515_RS422_485. Please do 
NOT use the drivers in its parent directory, E:\IO\OXFORD, since they 
are used for RS232 instead of RS422/485. 

 

 

 

 

 

 

 

 

4. Driver Installation for Win2000, XP and Vista 

1            5 

6           9 

9 Pins   Signal 

  1       TXD- (DATA-)(A) 
  2       TXD+  (DATA+)(B) 
  3       RXD+ 
  4       RXD- 
  5       GND 
  6       RTS- 
  7       RTS+ 
  8       CTS+ 
  9       CTS- 

Содержание MSC-104B

Страница 1: ... byte on chip FIFO Up to 921 6 Kbps baud rate over 700 Kbps data throughput Precise RS485 ATTATM Auto Transceiver Turn Around feature to disable the line driver by hardware Optional 15KV ESD surge and optical isolation protection models are available Supports Windows 98SE 2000 and XP 2003 Vista MSC 104B MSC 104B SI Installation Guide 1 Introduction 2 Connector and Jumper Layout Termination Resiste...

Страница 2: ...5 422 4 wire RS 422 mode 485 Default 2 wire RS 485 mode S1L S1H S1L Default Reserved for Future Use Please do NOT change it NO ECHO ECHO NO ECHO Default No echo data ECHO Transmitting data will be echoed back S2L S2H S2L Default Reserved for Future Use Please do NOT change it Please note that if the mode were set at 422 mode the ECHO settings will take no effect The Echo mode is useful for the app...

Страница 3: ...ERM S3 TERM S4 TERM IN TXD DATA and DATA Termination Resistor Enabled OUT Default TXD DATA and DATA Termination Resistor Disabled Note IN Jumper Installed OUT Jumper Not Installed 3 JP2 UART Input Clock Speed Selector RS 485 TXD Termination Resistor Enable Disable UART Input Clock Speed 14 7456MHZ the maximum baud rate is 926 1Kbps Default HI LO UART Input Clock Speed 1 8432MHZ the maximum baud ra...

Страница 4: ...ZIP format e g V6515_RS422_485 ZIP Please copy the file to your hard drive C or what folder you want unzip it before proceeding with your installations We assumed you copy the file to your hard drive C root directory and the unzipped folder is V6515_RS422_485 Please do NOT use the drivers in its parent directory E IO OXFORD since they are used for RS232 instead of RS422 485 4 Driver Installation f...

Страница 5: ...t will cause problems because the INF files will be conflict in this case Instead please browse to the correct location folder manually to make sure the correct drivers are chosen and installed correctly The Zip file is shipped in this folder Drivers for different OS are unzipped to different folders ...