PCI Multi-port Serial Card

 

 

 

2

 

 

 

 

 

 

RS-485 User:  Since the factory jumper settings are initially  set at 
2-wire RS-485 mode. There is no need to change any jumper 
settings from the default settings. 

 

RS-422 User:  Change the mode jumper away from the”485” 
position. Keep the other settings unchanged.   

1.

 

Mode Jumpers: 

 

 
 
 
 
 

Mode Settings for all S1~S4 Ports (JP1): 

Jumper Name 

Jumper Positions 

Mode and Termination Resistor 

Setting 

422/485 

422 

 

4-wire RS-422 mode   

485 

(Default) 

2-wire RS-485 mode 

S1L/S1H 

S1L 

(Default) 

Reserved for Future Use. Please do 

NOT change it. 

NO ECHO/ECHO 

NO ECHO 

(Default) 

No echo data 

 

ECHO 

 

Transmitting data will be echoed 

back 

S2L/S2H 

S2L 

(Default) 

Reserved for Future Use. Please do 

NOT change it. 

 

 

Please note that if the mode were set at “422” mode, the ECHO settings 
will take no effect. 

 

The Echo mode is useful for the application program to detect if the 
RS-485 bus were in a collision. If the echoed data was not equal to the 
transmitted data, then the bus was in a collision. 
 

422 

S1L 

NO ECHO 

S2L 

3. Jumper Settings 

485 

S1H 

NO ECHO 

S2H 

Содержание MSC-104B

Страница 1: ... byte on chip FIFO Up to 921 6 Kbps baud rate over 700 Kbps data throughput Precise RS485 ATTATM Auto Transceiver Turn Around feature to disable the line driver by hardware Optional 15KV ESD surge and optical isolation protection models are available Supports Windows 98SE 2000 and XP 2003 Vista MSC 104B MSC 104B SI Installation Guide 1 Introduction 2 Connector and Jumper Layout Termination Resiste...

Страница 2: ...5 422 4 wire RS 422 mode 485 Default 2 wire RS 485 mode S1L S1H S1L Default Reserved for Future Use Please do NOT change it NO ECHO ECHO NO ECHO Default No echo data ECHO Transmitting data will be echoed back S2L S2H S2L Default Reserved for Future Use Please do NOT change it Please note that if the mode were set at 422 mode the ECHO settings will take no effect The Echo mode is useful for the app...

Страница 3: ...ERM S3 TERM S4 TERM IN TXD DATA and DATA Termination Resistor Enabled OUT Default TXD DATA and DATA Termination Resistor Disabled Note IN Jumper Installed OUT Jumper Not Installed 3 JP2 UART Input Clock Speed Selector RS 485 TXD Termination Resistor Enable Disable UART Input Clock Speed 14 7456MHZ the maximum baud rate is 926 1Kbps Default HI LO UART Input Clock Speed 1 8432MHZ the maximum baud ra...

Страница 4: ...ZIP format e g V6515_RS422_485 ZIP Please copy the file to your hard drive C or what folder you want unzip it before proceeding with your installations We assumed you copy the file to your hard drive C root directory and the unzipped folder is V6515_RS422_485 Please do NOT use the drivers in its parent directory E IO OXFORD since they are used for RS232 instead of RS422 485 4 Driver Installation f...

Страница 5: ...t will cause problems because the INF files will be conflict in this case Instead please browse to the correct location folder manually to make sure the correct drivers are chosen and installed correctly The Zip file is shipped in this folder Drivers for different OS are unzipped to different folders ...

Отзывы: