background image

LNX-C501G-SFP Series

5-Port Industrial Compact Gigabit Unmanaged Ethernet Switch, with

4*10/100/1000Tx and 1*100/1000 SFP Slot

Hardware Manual

Version 1.0
(July 2022)

Содержание LNX-C501G-SFP Series

Страница 1: ...LNX C501G SFP Series 5 Port Industrial Compact Gigabit Unmanaged Ethernet Switch with 4 10 100 1000Tx and 1 100 1000 SFP Slot Hardware Manual Version 1 0 July 2022 ...

Страница 2: ...e product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual The information contained is subject to change without prior notice FCC Warning This equipment has b...

Страница 3: ...nterférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer de corriger les interférences par une ou plusieurs des mesures suivantes Réorientez ou déplacez l antenne de réception Augmentez la distance entre l équipement et le récepteur Connectez l équipement à une prise sur un circuit différe...

Страница 4: ...l Ethernet Switches LNX C501G SFP Series Hardware Manual v1 0 This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Страница 5: ...Dimensions 3 2 2 Front View Panel 4 2 3 LED Indicators 5 2 4 DIP Switch 5 2 5 Relay Contact Alarm Warning 6 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wiring the Power Inputs 7 2 9 Wiring the Fault Alarm Contact 8 2 10 Grounding Note 10 3 Mounting Installation 11 3 1 DIN Rail Mounting 11 3 2 Wall Mounting 12 4 Hardware Installation 14 4 1 Installation Steps 14 4 2 Maintenance and Service 15 4 3 Troubl...

Страница 6: ...o 65 C and EOT 40 C to 75 C This is an industrial grade unit applicable for networking applications in factory automation ITS power utility water wastewater treatment plants or any application that needs a compact solution 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx RJ45 ports and 1 100 1000 SFP slot Store a...

Страница 7: ...positif de protection sur l entrée d alimentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du commutateur Ethernet industriel seront décrits dans ce manuel d utilisation Warning Labels The caution label means that you should check certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes d avertisseme...

Страница 8: ...et Switches LNX C501G SFP Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 64 9mm x 89 8mm x 110mm Figure 2 1 Physical Dimensions 3 ...

Страница 9: ...ntaira Technologies Industrial Ethernet Switches LNX C501G SFP Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 4 ...

Страница 10: ...ve P2 Green On Power Input 2 is active Off Power Input 2 is inactive Fault Red On 1 Power input 1 or 2 is inactive 2 Port link down Broken Off No events occur LAN Port 2 5 LNK ACT Speed Green On Connected to network 1000Mbps Flashing Networking is active Off Not connected to network Green On Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network SFP Port LNK ACT...

Страница 11: ...y trigger event 4 Cable short per port Key trigger event 5 One of the channels in Dual PD fail Note When the relay is triggered because of event 2 5 the relay contact alarm will update the status every 30 seconds If there is no event happening for 30 seconds the relay contact alarm will be turned off If the user disables the failed PoE port by removing the cable or DIP switch manually the relay wi...

Страница 12: ...Note and signs represent the polarity of the wires that make up each wire pair 2 7 Cabling Use the four twisted pair category 5e or the above cabling for the RJ45 port connections The cable between the switch and the link partner switch hub workstation etc must be less than 100 meters 328 ft in length The small form factor pluggable SFP is a compact optical transceiver used in optical communicatio...

Страница 13: ...WR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 11 Figure 2 11 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 12 Figure 2 12 Power Terminal Block Caution Only use copper conductors 125 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG Attention Uti...

Страница 14: ...ged industrial switch only and form a normal open circuit An example is shown below in Figure 2 13 Figure 2 13 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm Attention Le calibre des fils du bornier doit être compris entre 12 et 24 AWG ...

Страница 15: ...netic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 14 Figure 2 14 Grounding Screw Symbol Caution Using a shielded cable achieves better electromagnetic compatibility Attention L utilisation d un câble blindé permet une meilleure compatibilité électromagnétique 10 ...

Страница 16: ...e rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail onto the track as shown below in Figu...

Страница 17: ...de industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l a...

Страница 18: ...ial Ethernet Switches LNX C501G SFP Series Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 13 ...

Страница 19: ... If it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the P...

Страница 20: ...pter is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment Select the proper UTP or STP cable in order to construct the network Use an unshielded twisted pair UTP or shield twisted pair STP cable for RJ45 connections 100Ω Category 5e for 10 100Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters...

Страница 21: ... Switch Architecture Back Plane Switching Fabric 10 0Gbps Processing Type Store and Forward Flow Control IEEE 802 3x for full duplex mode back pressure for half duplex mode Transfer Rate 14 880pps for 10Base T Ethernet 148 800pps for 100Base T Fast Ethernet 1 488 000pps for Gigabit Ethernet Packet Buffer 1Mbit Jumbo Frame 10K MAC Table Size 8K VLAN Group 4095 IGMP Group 1024 Port Interface Etherne...

Страница 22: ...mounting Power Requirement Input Voltage 12 48VDC Redundant Input Power Connection 1 removable 6 contact terminal block Relay Contact 24VDC 1A resistive Overload Current Protection Present Reverse Polarity Protection Present the unit will not be on if power reverse System Power Consumption 4 6 Watts Environmental Limits Operating Temperature STD 10 C to 65 C EOT 40 C to 75 C Storage Temperature 40...

Страница 23: ...s Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 18 ...