background image

                                               LNX-602N User’s Manual 

  Antaira Technologies, LLC 

21 

 

System Reboot interface 

 

 

5.1.3 

 

Port Configuration 

 

5.1.3.1   Port Control 

By this function, you can set the state, speed/duplex, flow control, and security of the 

port. 

 

Port Control interface 

 

The following table describes the labels in this screen. 

Label 

Description 

Port NO.

 

Port number for setting. 

State

 

Enable/Disable the port. 

Speed/Duplex

 

You can set Auto-negotiation, 100 full,100 half,10 full,10 half 

mode. 

Flow Control 

Support symmetric and asymmetric mode to avoid packet loss 

when congestion occurred.     

Apply 

Click “

Apply

” to activate the configurations. 

5.1.3.2  Port Status 

The following information provides the current port status. 

Содержание LNX-602N

Страница 1: ...1116 sales enochsystems com Copyright 2013 Enoch Systems LLC Enoch Systems and the Enoch Systems logo are trademarks or registered trademarks of Enoch Systems LLC and or its affiliates in the U S and other countries Third party trademarks mentioned are the property of their respective owners All rights reserved ...

Страница 2: ...6 port Industrial Managed Ethernet Switch User s Manual Version 1 2 ...

Страница 3: ... Hardware Overview 7 3 1 Front Panel 7 3 2 Front Panel LEDs 9 3 3 Bottom Panel 9 3 4 Rear Panel 10 Cables 11 4 1 Ethernet Cables 11 4 1 1 100BASE TX 10BASE T Pin Assignments 11 4 2 Fibers 12 WEB Management 13 5 1 Configuration by Web Browser 13 5 1 1 About Web based Management 13 5 1 2 Basic Setting 14 5 1 2 1 Switch setting 14 5 1 2 2 Admin Password 15 5 1 2 3 IP configuration 15 5 1 2 4 SNTP Con...

Страница 4: ...e 22 5 1 4 2 Redundant Ring 23 5 1 4 3 RSTP 24 5 1 5 SNMP Configuration 27 5 1 5 1 SNMP Agent Setting 27 5 1 5 2 SNMP Trap Setting 28 5 1 6 VLAN 29 5 1 6 1 VLAN Configuration Port Based 29 5 1 7 Warning 29 5 1 7 1 Fault Alarm 30 5 1 8 Front Panel 34 5 1 9 Save Configuration 34 5 1 10 LLDP 35 Technical Specifications 36 ...

Страница 5: ...ironment and humid condition The LNX 602N switch can be managed by Web 1 2 Software Features World s fastest Redundant Ethernet Ring Recovery time 10ms over 250 units connection Supports Ring Coupling Dual Homing and RSTP over Redundant Ring Support fast recovery mode Easy web configuration 1 3 Hardware Features Wide Operating Temperature 40 to 75 o C Storage Temperature 40 to 85 o C Operating Hum...

Страница 6: ...s a DIN Rail kit on rear panel The DIN Rail kit helps switch to fix on the DIN Rail It is easy to install the switch on the DIN Rail 2 1 1 Mount LNX 602N Series on DIN Rail Step 1 Slant the switch and mount the metal spring to DIN Rail Step 2 Push the switch toward the DIN Rail until you heard a click sound Metal Spring ...

Страница 7: ...thod for users to fix the switch A wall mount panel can be found in the package The following steps show how to mount the switch on the wall 2 2 1 Mount LNX 602N Series on wall Step 1 Remove DIN Rail kit Step 2 Use 6 screws that can be found in the package to combine the wall mount panel Just like the picture shows below ...

Страница 8: ...gies LLC 6 The screws specification shows in the following two pictures In order to prevent switches from any damage the screws should not be larger than the size that is used in switch Pozidrive Step 3 Mount the combined switch on the wall ...

Страница 9: ...n the LNX 602N Port Description 10 100 RJ 45 fast Ethernet ports 10 100Base T X RJ 45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Fiber port 100BaseFX Reset Push reset button 2 to 3 seconds to reset the switch Push reset button 5 second to reset the switch into Factory Default ...

Страница 10: ...4 LED for R M Ring master When the LED light on it means that the switch is the ring master of the Redundant Ring 5 LED for Ring When the led light on it means the Redundant Ring is activated 6 LED for Fault Relay When the fault occurs the amber LED will be light on 7 Reset button Push the button 3 seconds for reset 5 seconds for factory default 8 10 100Base T X Ethernet ports 9 LED for Ethernet p...

Страница 11: ... blinking Ring work normally Fault Amber On Fault relay Power failure or Port down fail 10 100Base T X Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmitted Full Duplex Amber On Port works under full duplex 100Base FX Fiber ports ACT Green Blinking Data transmitted LNK Amber On Port link up 3 3 Bottom Panel The bottom panel components of LNX 602N are showed as below 1 Termina...

Страница 12: ...LNX 602N User s Manual Antaira Technologies LLC 10 3 4 Rear Panel The rear panel components of LNX 602N are showed as below 1 Screw holes for wall mount kit 2 Din Rail kit ...

Страница 13: ...th Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ 45 4 1 1 100BASE TX 10BASE T Pin Assignments With 100BASE TX 10BASE T cable pins 1 and 2 are used for transmitting data and pins 3 and 6 are used for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 TD 2 TD 3 RD 4 Not used 5 Not used 6 RD 7 Not used 8 Not used The LNX 602N sw...

Страница 14: ...ed Not used 8 Not used Not used Note and signs represent the polarity of the wires that make up each wire pair 4 2 Fibers The following two models LNX 602N MM LNX 602N SS30 have fiber optical ports The fiber optical ports are in multi mode 0 to 2 km 1310 nm in 50 125 µm 62 5 125 µm and single mode 9 125 µm with SC connector Please remember that the TX port of Switch A should be connected to the RX...

Страница 15: ...to reduce network bandwidth consumption enhance access speed and present an easy viewing screen Note By default IE5 0 or later version does not allow Java Applets to open sockets You need to explicitly modify the browser setting in order to enable Java Applets to use network ports Preparing for Web Management The default value is as below IP Address 192 168 10 1 Subnet Mask 255 255 255 0 Default G...

Страница 16: ... Main interface 5 1 2 Basic Setting 5 1 2 1 Switch setting Switch setting interface The following table describes the labels in this screen Label Description System Name Assign the name of switch The maximum length is 64 bytes System Description Display the description of switch ...

Страница 17: ... assigned by manufacturer default 5 1 2 2 Admin Password Change web management login username and password for the management security issue Admin Password interface The following table describes the labels in this screen Label Description User name Key in the new username The default is admin New Password Key in the new password The default is admin Confirm password Re type the new password Apply...

Страница 18: ...the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabling you do not need to assign the IP address The network DHCP server will assign the IP address for the switch and it will be displayed in this column The default IP is 192 168 10 1 Subnet Mask Assign the subnet mask for the IP address If DHCP client function is enabling you do ...

Страница 19: ...ht Saving Time Enable or disable daylight saving time function When daylight saving time is enabling you need to configure the daylight saving time period UTC Time zone Set the switch location time zone The following table lists the different location time zone for your reference Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11 am Oscar Time Zone 2 hours 10 am ADT...

Страница 20: ...n Standard 10 hours 2 am Nome Alaska 11 hours 1 am CET Central European FWT French Winter MET Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USS...

Страница 21: ...the Daylight Saving beginning time and Daylight Saving ending time Both will be different each year Daylight Saving Offset Set up the offset time Switch Timer Display the switch current time Apply Click Apply to activate the configurations 5 1 2 5 Backup Restore You can save current EEPROM value of the switch to TFTP server then go to the TFTP restore configuration page to restore the EEPROM value...

Страница 22: ...rations 5 1 2 6 Upgrade Firmware Upgrade Firmware allows you to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server Update Firmware interface 5 1 2 7 Factory Default Factory Default interface Reset switch to default configuration Click Reset to reset all configurations to the default value You can select Keep current IP ...

Страница 23: ... following table describes the labels in this screen Label Description Port NO Port number for setting State Enable Disable the port Speed Duplex You can set Auto negotiation 100 full 100 half 10 full 10 half mode Flow Control Support symmetric and asymmetric mode to avoid packet loss when congestion occurred Apply Click Apply to activate the configurations 5 1 3 2 Port Status The following inform...

Страница 24: ...tiple ports to one or more switches The LNX 602N with its fast recovery mode will provide redundant links Fast Recovery mode supports 4 priorities only the first priority will be the act port the other ports configured with other priority will be the backup ports Fast Recovery Mode interface The following table describes the labels in this screen Label Description ...

Страница 25: ...y to activate the configurations 5 1 4 2 Redundant Ring The recovery time of the Redundant Ring is less than 10 mS over 250 units of connections It can reduce unexpected malfunction caused by network topology change Redundant Ring technology supports three Ring topologies for network redundancy Redundant Ring Coupling Ring and Dual Homing Redundant Ring interface The following table describes the ...

Страница 26: ... Set a port as coupling port The coupled four ports of four switches will be run at active backup mode Control Port Link to Control Port of the switch of the same ring Control Port used to transmit control signals Dual Homing Mark to enable Dual Homing By selecting Dual Homing mode Redundant Ring will be connected to normal switches through two RSTP links ex backbone Switch The two links work as a...

Страница 27: ...rity and is selected as the root If the value changes you must reboot the switch The value must be multiple of 4096 according to the protocol standard rule Max Age 6 40 The number of seconds a bridge waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The time that controls switch sends out the...

Страница 28: ...It is served by a point to point LAN segment or it can be connected to two or more bridges i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling Admin Edge The port is directly connected to end stations and it cannot create bridging loop in the network To configure the por...

Страница 29: ...rs switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 1 5 1 SNMP Agent Setting You can set SNMP agent related information by Agent Setting Function SNMP Agent Sett...

Страница 30: ...raps the system alerts generated by the switch If no trap manager is defined no traps will issue Create a trap manager by entering the IP address of the station and a community string To define management stations as trap manager and enter SNMP community strings and selects the SNMP version SNMP Trap Setting interface The following table describes the labels in this screen Label Description Server...

Страница 31: ...ration Port Based Packets can go among only members of the same VLAN group Note all unselected ports are treated as belonging to another single VLAN If the port based VLAN enabled the VLAN tagging is ignored VLAN Configuration Port Based VLAN interface The following table describes the labels in this screen Label Description Group Mark the blank to assign the port into VLAN group Apply Click Apply...

Страница 32: ...etting The SYSLOG is a protocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting interface The following table describes the labels in this screen Label Description SYSLOG Mode Disable disable SYSLOG Client Only log to local system Server Only log to a remote SYSLOG server Both log to both of local and remote ser...

Страница 33: ... table System event log interface The following table describes the labels in this screen Label Description Page Select LOG page Reload To get the newest event logs and refresh this page Clear Clear log Help Show help file System Warning SMTP Setting The SMTP is Short for Simple Mail Transfer Protocol It is a protocol for e mail transmission across the Internet Please refer to RFC 821 Simple Mail ...

Страница 34: ...ername the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E mail address It supports up to 6 recipients per mail Apply Click Apply to activate the configurations Help Show help file System Warning Event Selection SYSLOG and SMTP are the two warning methods that supported by the system Check the corresponding ...

Страница 35: ...le describes the labels in this screen Label Description System Event System Cold Start Alert when system restart Redundant Ring Topology Change Alert when Redundant Ring topology change Port Event Disable Link Up Link Down Link Up Link Down Apply Click Apply to activate the configurations Help Show help file ...

Страница 36: ...on If any configuration changed Save Configuration should be clicked to save current configuration data into the permanent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface The following table describes the labels in this screen Label Description Save Save all configurations Help Show help file ...

Страница 37: ...rmation to other nodes on the network and store the information it discovers LLDP interface The following table describes the labels in this screen Label Description LLDP Protocol Enable or Disable LLDP function LLDP Interval The interval of resend LLDP by default at 30 seconds Apply Click Apply to activate the configurations Help Show help file ...

Страница 38: ...ocessing Store and Forward Firmware upgrade TFTP Ring redundancy RSTP Redundant Ring Couple Ring Dual Homing Fast recovery Interface RJ45 Ports 10 100Base T X Auto MDI MDI X Fiber Ports 100 Base FX SC Connector Multi Mode 0 to 2 km 1310 nm 50 125 µm to 62 5 125 µm Single Mode 0 to 30 km 1310 nm 9 125 µm LED Indicators Per Unit Power x 3 Green RJ45 Ports Per Port Link Activity Green Blinking Green ...

Страница 39: ...e 40 to 85 o C Operating Humidity 5 to 95 non condensing Mechanical Dimensions W x D x H 52 mm W x 106 mm D x 144 mm H Casing IP 30 protection Regulatory Approvals Regulatory Approvals FCC Part 15 CISPER EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 CS Shock IEC 60068 2 27 Free Fall IEC 60068 2 32 Vibration IEC 60068 2 6 Warranty 5 years ...