2.6 Cabling
Use the four twisted-pair, category 5e, or the above cabling for the RJ45 port connections. The cable between the switch
and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) in length.
2.7 Wiring the Power Inputs
Caution:
Please follow the steps below when inserting the power wire.
Attention:
Veuillez suivre les étapes ci-dessous lors de l'insertion du câble d'alimentation.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts on the terminal block
connector as shown below in
Figure 2.6
.
Figure 2.6 - Power Terminal Block
2.
Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.7
.
Figure 2.7 - Power Terminal Block
Caution:
Only use copper conductors,
125°C
, tighten to
5 lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.
Attention:
Utilisez uniquement des conducteurs en cuivre,
125°C
, serrez à
5 lb.
Le calibre des fils du bornier doit être compris entre
18
et
20 AWG.