and the link partner (switch, hub, workstation, etc.) must be less than 100 meters
(328 ft.) long.
Fiber segment using single-mode connector type must use 9/125μm single-mode fiber
cable.
Fiber segment using multi-mode connector type must use 50 or 62.5/125 μm multi-
mode fiber cable.
Wiring the Power Inputs
Please follow the steps below to insert the power wire.
Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+,V2-)
contacts on the terminal block connector.
Tighten the wire-clamp screws to prevent the wires from loosening.
Note
Use Copper Conductors Only, 60/75
°
C, Tighten to 5 lb in
The wire gauge for the terminal block should range between 12 ~ 18
AWG.