5
Antaira Technologies - Industrial Ethernet Switches
LNP-0500G-24 Series User Manual V1.0
2.4 LED Indicators
There are LED light indicators located on the front panel of the industrial Ethernet switch that
display the power status and network status. Each LED indicator has a different color and has
its own specific meaning, see below in
Table 2.1
.
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
Fault
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 are both functional, or no power
inputs
PoE Indicators
(Port 1~4)
Green
On
The port is supplying power to the powered device
Off
No powered-device attached or power supplying fails
LNK/ACT
(SFP Port)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
LAN Port 1 ~ 5
(Left LED)
Green
On
Connected to network, 1000Mbps
Flashing Networking is active
Off
Not connected to network
LAN Port 1 ~ 5
(Right LED)
Green
On
Connected to network, 100Mbps/10Mbps
Flashing
Networking is active
Off
Not connected to network
Table 2.1
LED Indicators for LNP-0500G-24 Series
2.5 Ethernet Ports
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX)
: The RJ-45 ports (LAN 1~5) are auto-sensing for
10/100/1000Base-T, or 100Base-Tx devices connections. Auto MDI/MDIX means that the switch
can connect to another switch or workstation without changing the straight-through or crossover
cabling. See the figures shown below for straight-through and crossover cabling schematics.