background image

Antaira Technologies - Industrial Ethernet Switches 

LMP-0602-XX-V2 Series Hardware Manual V1.0 

 

13 

 

4.2  Maintenance and Service 

 

If the device requires servicing of any kind, the user is required to disconnect and remove it from its 
mounting. The initial installation should be done in a way that makes this as convenient as possible. 

 

Voltage/Power lines should be properly insulated as well as other cables. Be careful when handling 
them so as to not trip over. 

 

Do not under any circumstance insert foreign objects of any kind into the heat dissipation holes 
located in the different faces of the device. This may not only harm the internal layout, but might 
cause harm to user as well. 

 

Do not under any circumstance open the device for any reason. Please contact your dealer for any 
repair needed or follow the instructions within the manual. 

 

Clean the device with dry soft cloth. 

 

 

5.  Technical Specifications 

Table 5.1 

has the technical specifications fo

r Antaira’s LMP-0602-XX-V2 series: 

Technology 

L2 Switching 

Port/MAC/Protocol/IP Subnet-based VLAN, VLAN trunking, 
GARP/GVRP, Loop Guard, Link Aggregation static/LACP, 
BPDU guard, Error disable recovery, IGMPv2 snooping, MLD 
snooping, IGMP filtering, IPMC throttling / filtering leave proxy, 
DHCP snooping, ARP, MEP, G.8032 v1/v2 

L3 Switching 

DHCP option82, static routes 

QoS 

802.1p Queueing, Input priority mapping, Storm control for 
Unicast/Multicast/Broadcast, Port/Queue/ACL policer, Port 
egress shaper, Queue egress shaper, DiffServ (DSCP), Tag 
remarking, Scheduler mode 

Power Saving 

ActiPHY, PerfectReach, IEEE 802.3az EEE power management 

Network Redundancy 

STP/RSTP/MSTP, port trunk with LACP, ERPS v1/v2 (<50ms) 

Configuration 

Http, Https, Telnet, SSH, CLI, TFTP, SNMP v3 

System / Diagnostics 

Dual Image Protection, PING, PING6 

Switch Properties 

Back-Plane (Switching 
Fabric) 

Non-blocking 

Priority Queues 

Processing Type 

Store and Forward 

Flow Control 

IEEE 802.3x flow control, back pressure flow control 

Transfer Rate 

14,880pps for Ethernet Port 

Содержание LMP-0602-M-V2

Страница 1: ...Switches LMP 1204G SFP Series User Manual V2 1 i LMX 0602 XX V2 Series 6 Port Industrial Managed Ethernet Switch w 4 10 100Tx and 2 100Fx Multi Mode Single Mode 48 55VDC Power Input Version 2 Hardware...

Страница 2: ...ers Notice Copyrights 2019 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed u...

Страница 3: ...on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and rece...

Страница 4: ...y Precaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Reset Button 7 2 6 Ethernet Ports 7 2 7 Cabling 8 2 8 Wiring the Power Input...

Страница 5: ...rnet Ring Protection Switch protocol that has a 50ms network recovery time The advanced network filtering and security functions such as IGMP VLAN QoS SNMP RMON Modbus TCP and 802 1X HTTPS SSH SSL inc...

Страница 6: ...ia TFTP and HTTP Configuration Backup USB Port 1 3 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100Tx PSE 30W Port RJ45 Ports...

Страница 7: ...e 1 5 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports ca...

Страница 8: ...602 XX V2 Series Hardware Manual V1 0 4 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0602 XX V2 series W x D x H is 54mm x 99mm x 142m...

Страница 9: ...of the LMP 0602 XX V2 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure2 3 Top Panel View of LMP 0602 XX V2 Series 6 Pin Removal...

Страница 10: ...e Red Preconfigured alarms are detecting failure Off Switch is in the process of booting Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Networ...

Страница 11: ...ctions Auto MDI means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover c...

Страница 12: ...chematic Figure 2 5 Crossover Cable Schematic 2 7 Cabling Use the four twisted pair category 5e or the above cabling for the RJ 45 port connections The cable between the switch and the link partner sw...

Страница 13: ...uge for the terminal block should range between 12 24AWG 2 10 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connectio...

Страница 14: ...de of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket...

Страница 15: ...all mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening th...

Страница 16: ...e refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the indu...

Страница 17: ...ical Specifications Table 5 1 has the technical specifications for Antaira s LMP 0602 XX V2 series Technology L2 Switching Port MAC Protocol IP Subnet based VLAN VLAN trunking GARP GVRP Loop Guard Lin...

Страница 18: ...le 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Mechanical Characteristics Housing Metal IP30 protection Dimensions 5...

Страница 19: ...e Fall Shock Vibration IEC60068 2 32 IEC60068 2 27 IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 LMP 0602 XX V2 Series Technical Specifications Antaira Customer Se...

Отзывы: