background image

Antaira Industrial Ethernet Switches 

LMP-0501 Series User Manual V1.0 

 

33 

 

the port as an edge port, set the port 

to “

True

”. 

Admin Non STP

 

The port includes the STP mathematic calculation.     

True

 is not including STP mathematic calculation.     

False

 is including the STP mathematic calculation. 

 

Click the 

“Apply” button to save changes. 

 

 

MSTP (Multiple Spanning Tree Protocol)

 

It is defined in IEEE 802.1s, it 

can map a group of VLAN’s into a single Multiple Spanning Tree 

instance (MSTI). In fact, 

the Spanning Tree Protocol is applied separately for a set of VLAN’s 

instead of the whole network. Different root switches and different STP parameters can be 

individually configured for each MSTI. So, one link can be active for one MSTI and the other link 

active for the second MSTI. This enables some degree of load-balancing and generally two 

MSTI’s are used in the network for easier implementation. 

 

5.6.3 MSTI Status 

Users can display the MSTI root status and port status by selecting the instance ID number 

from 1 to 15 by clicking on the dropdown box from the “MSTI Status” interface.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 5.32 

– RSTP Configuration Terms & Value Description 

Figure 5.33 

– MSTI Status Interface 

Содержание LMP-0501 Series

Страница 1: ...ira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 i LMP 0501 Series 5 Port Industrial PoE Managed Ethernet Switches 4 10 100Tx 30W Port 1 100Fx 48 55VDC Power Input User Manual Version...

Страница 2: ...Copyrights 2014 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the co...

Страница 3: ...of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that t...

Страница 4: ...ontents 2 1 5 Safety Precaution 3 2 Hardware Description 4 2 1 Physical Dimensions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Ethernet Ports 7 2 6 2 6 Fiber Port 7 2 7 Cabling 8 2 8 W...

Страница 5: ...5 3 Port Management 18 5 3 1 Port Status 18 5 3 2 Port Configuration 18 5 4PoE Power over Ethernet 19 5 4 1 PoE Configuration 19 5 4 2 Ping Alarm 20 5 4 3 PoE Schedule 21 5 5 ERPS 21 5 5 1 ERPS Statu...

Страница 6: ...ooping Status Table 38 5 9 QoS Traffic Prioritization 39 5 9 1 QoS Classification 39 5 9 2 CoS Mapping 40 5 9 3 ToS Mapping 41 5 10 Port Mirroring 42 5 11 SNMP 43 5 11 1 SNMP Agent 43 5 11 2 SNMP Trap...

Страница 7: ...5 14 Maintenance 49 5 14 1 Upgrade 49 5 14 2 Reboot 50 5 14 3 Default 50 5 15 Configuration 50 5 15 1 Save 51 5 15 2 Backup Store 51 5 15 3 Auto Load Backup 52 5 16 Logout 53 6 Command Line Interface...

Страница 8: ...Layer 2 Ethernet configurable settings This product series is IP30 rated and DIN rail mountable There are two operating temperature models either the STD 10 C to 70 C or the EOT 40 C to 75 C It also p...

Страница 9: ...single mode 30Km Store and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 48 55V redundant with a 6 pin removal...

Страница 10: ...afety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling i...

Страница 11: ...ription 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0501 series 5 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port and 1 100Fx SC ST fib...

Страница 12: ...trial PoE managed Ethernet switches is shown below in Figure 2 2 2 3 Top View Figure 2 3 below shows the top panel of the LMP 0501 series switch that is equipped with one 6 pin removal terminal block...

Страница 13: ...On System is ready Off System is booting Red On Fault Alarm Off System is in normal state Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Netwo...

Страница 14: ...all network connections to PCs servers other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end o...

Страница 15: ...ll cause the port to NOT work normally Caution This is a Class 1 Laser LED product Don t stare into the laser LED beam 2 7 Cabling Twisted pair segments can be connected with an unshielded twisted pai...

Страница 16: ...o 5lbs The wire gauge for the terminal block should range between 18 20 AWG 2 9 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture s...

Страница 17: ...ail bracket on the rear side of the industrial Ethernet switch 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch ins...

Страница 18: ...wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corner...

Страница 19: ...mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED...

Страница 20: ...nagement features that allow users to manage the switch from anywhere on the network through any Internet browser such as Internet Explorer version 9 0 or above is recommended Firefox Chrome and many...

Страница 21: ...utton then the main status page of the Web Console will appear as below Figure 5 2 The online image of the switch will display the real time ports connection status 5 2 Basic Setting 5 2 1 System Info...

Страница 22: ...label to describe this PoE Managed Switch System Location Factory Default Blank Users can use this field to insert the physical location of this switch e g telephone closet 3rd floor The maximum allo...

Страница 23: ...non zero DHCP will stop and the configured IP settings will be used The DHCP client will announce the configured System Name as hostname to provide DNS lookup IP Address The unit default IP is 192 168...

Страница 24: ...ocal time or click Sync with browser button to have the local time setup automatically Select Your Time Zone Users can use the dropdown box to setup the switch s location time zone Enable NTP Client E...

Страница 25: ...abel for each port under each Port Name box enable or disable each port function state the speed duplex of each port and enable or disable the flow control of the port Terms Value Description Port No...

Страница 26: ...button to save changes Click to undo any changes made locally and revert to previously saved values 5 4PoE Power over Ethernet LMP 0501 series is one of Antaira s industrial PoE managed switches that...

Страница 27: ...isable any PoE port function Consumption Set the PoE power output limit value The maximum value must less than 30 0W Click the Apply button to save changes 5 4 2 Ping Alarm The PoE ping alarm function...

Страница 28: ...covers as soon as possible when a point of failure occurs The most popular ones are RSTP 802 1w and MSTP 802 1s For industrial applications the ERPS G 8032 are highly recommended since they can achiev...

Страница 29: ...is called the RPL neighbor node that is responsible for blocking its end of the RPL under normal condition Other participating switches adjacent to the RPL owner or neighbor in a ring are members or R...

Страница 30: ...as Ring port 0 Role Set the ERPS role as Owner Neighbor or Normal Owner In charge of blocking one side of RPL link It will prevent the packet flow from its blocked port Neighbor In charge of blocking...

Страница 31: ...block permanently until the next event happen Non Revertive The failed ring link the port attached to it will remain blocked even the situation is eliminated Click the Apply button to save changes 5 5...

Страница 32: ...V1 0 25 Step 3 When the RSTP CIST Configuration page shows up set Mode to Disable as shown in Figure 5 22 Step 4 Press the Apply button in the lower right corner Figure 5 23 Figure 5 22 RSTP CIST Conf...

Страница 33: ...scenarios that describe how to configure the ERPS using Antaira s industrial managed Ethernet switches Users can reference it to configure the managed switch as an RPL configured architecture shown i...

Страница 34: ...has been chosen as an example Step 2 Choose a specific port from the dropdown box next to ring port 1 then set it as Normal from the dropdown box next to Role which is located below ring port 1 At th...

Страница 35: ...choose a specific port number under Ring Port 0 and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as show...

Страница 36: ...port number has been chosen within a managed switch s ERPS ring setting the incorrect configurations may lead to unexpected errors 5 5 3 2 Scenario B Non Configured Architecture In some situations us...

Страница 37: ...g Port 0 and Ring Port 1 cannot be duplicated 5 6 Spanning Tree The Spanning Tree Protocol STP defined in the IEEE Standard 802 1d can be created within a mesh network of connected layer 2 switches Th...

Страница 38: ...needs for having different STP for each VLAN Therefore in a large networking environment that employs many VLANs MSTP can be more useful than legacy STP 5 6 1 RSTP Status Figure 5 30 shows the RSTP a...

Страница 39: ...40 as the number of seconds a bridge waits without receiving STP configuration messages before attempting a reconfiguration Path Cost 0 200000000 Enter a value from 1 through 200000000 to define the...

Страница 40: ...the Spanning Tree Protocol is applied separately for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each MSTI So...

Страница 41: ...C address of the bridge switch Revision User can insert the value from 0 65535 MTSI Instance Instance No VLAN Group There are 1 15 instance number user can insert which VLAN Group info into the belong...

Страница 42: ...e the path cost value from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port Priority User can decide which port should be blocked by priority in LAN by selec...

Страница 43: ...tings Tagged based VLAN is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into...

Страница 44: ...enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an IGMP report for a given multicast group from a...

Страница 45: ...st filtering network devices only forward multicast traffic to the ports that are connected to registered end stations Terms Value Description IGMP Protocol Check the box to enable or disable IGMP Sno...

Страница 46: ...This ensures that network traffic is prioritized according to specified criteria and receives preferential treatments Traffic Prioritization includes three modes port base 802 1p COS and TOS DSCP By...

Страница 47: ...ode Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated as non IP frames CoS Class Of Service is well known as 802 1p It describ...

Страница 48: ...oS priority control It is fully decoded to determine the priority from the 6 bit ToS field in the IP header The most significant 6 bits of the ToS field are fully decoded into 64 possibilities and the...

Страница 49: ...Enable Port Mirroring function by checking the box Go To Interface Users can use the dropdown box to choose the destination port as Port to mirror on feature Monitor Direction Users can select the mo...

Страница 50: ...performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11 1...

Страница 51: ...tem Warning System warning function is very important for managing a switch Users can manage the switch by Syslog System Event Log and Email Server setup for Advanced Notice in any event type Event Ty...

Страница 52: ...and store SYSLOG data and warning file to USB storage device through built in USB Port and the file name is message All Log to all local server USB port and remote SYSLOG server at the same time Notic...

Страница 53: ...e system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log information Users also can click the Refresh button to have the most updat...

Страница 54: ...n username Password the authentication password Recipient E mail Address es User can setup up to 4 recipient E mail addresses to receive any system warning message Click the Apply button to save chang...

Страница 55: ...m type such as power failure port link down or broken through the Fault Alarm setting interface to trigger this function 5 13 MAC Table The MAC address table is the filtering database that supports qu...

Страница 56: ...tton to save all the settings 5 14 Maintenance Under the maintenance section users can execute updated firmware upgrades system reboots and reset the system to factory default 5 14 1 Upgrade Antaira i...

Страница 57: ...file1 folder file2 5 14 2 Reboot Users can click the Apply button under the Reboot interface to reboot the switch 5 14 3 Default Users can reset the switch to Factory Default by clicking the Apply but...

Страница 58: ...on settings Users can keep the USB storage device plugged in with the switch to enable the USB Auto Backup function to allow the switch s configuration settings to backup to the USB storage device whe...

Страница 59: ...me and click the button for Backup If the folder or filename does not exist the system will generate it automatically Ex file1 folder file2 Save Startup Config to USB Fill in the folder and filename a...

Страница 60: ...tch to the USB And the file name is startup config 5 16 Logout Users can logout of the web console interface by pointing at and clicking logout from the menu 6 Command Line Interface Management 6 1 Ab...

Страница 61: ...0501 Series User Manual V1 0 54 Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop click on Start Programs Accessories Communications Hyper Terminal S...

Страница 62: ...itches LMP 0501 Series User Manual V1 0 55 Step 3 Select the COM port number Step 4 The COM port property settings are as follows 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop...

Страница 63: ...assword then press Enter CLI Management by Telnet Users can use TELNET to configure the switches The default value is below IP Address 192 168 1 254 Subnet Mask 255 255 255 0 Default Gateway none User...

Страница 64: ...m uptime configure show system mac configure show system version firmware configure show system version loader configure show environment power 1 configure show environment power 2 configure show envi...

Страница 65: ...weekly time configure no ntp client enable Configure no ntp client timeserver configure no clock timezone configure no ntp sync schedule enable configure no ntp sync minute configure no ntp sync hour...

Страница 66: ...terface show duplex interface show link rx interface show link tx interface show link summary interface show interface transceiver interface VLAN name vlan_name vlan member member_portlist untag_portl...

Страница 67: ...port1 owner neighbor g8032 aps channel channel ID g8032 revertive g8032 clear g8032 port0 interface interface name g8032 port1 interface interface name g8032 fs g8032 ms g8032 ring id erps ring ID g80...

Страница 68: ...terface show power inline power supply configure show power inline total consumption configure show power inline threshold configure STP spanning tree enable configure spanning tree mode rstp mst conf...

Страница 69: ...nning tree port priority interface show spanning tree link type interface show spanning tree auto edge interface show spanning tree admin edge interface show spanning tree stp interface spanning tree...

Страница 70: ...configure no event smtp warm start configure no event smtp authentication failure configure no event smtp erps change configure no event smtp interface INTERFACE_NAME up down configure show event smtp...

Страница 71: ...nfigure event alarm interface INTERFACE_NAME up down configure no event alarm power1 configure no event alarm power2 configure no event alarm interface INTERFACE_NAME up down configure show event alar...

Страница 72: ...ion enable configure show smtp authentication username configure show smtp receive 1 2 3 4 configure SNMP snmp server enable v1 v2c only v3 only configure snmp server community ro rw community_name co...

Страница 73: ...p version configure no snmp trap community configure no snmp trap inform retry configure no snmp trap inform timeout configure no snmp trap v3 user configure no snmp trap v3 level configure no snmp tr...

Страница 74: ...priority_type configure no qos map dscp priority_type configure no qos trust interface no qos default cos interface show qos queue schedule configure show qos map cos priority_type configure show qos...

Страница 75: ...igure show igmp snooping fast leave interface Save and Load Configuration File to from USB 1 CLI enable configure terminal copy running config usb path Fill in the folder and filename behind the copy...

Страница 76: ...gure terminal copy usb startup config path Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 4 CLI enable configure terminal copy usb firmware path Fill...

Страница 77: ...nual V1 0 70 5 CLI enable configure terminal Syslog mode usb or all Select USB or ALL it can auto save the waning file to USB And the file name is message 6 CLI enable configure terminal usb auto load...

Страница 78: ...hernet Ring Protection Switch IEEE 802 1q Virtual LANs VLAN IEEE 802 1x Port based Network Control Authentication IEEE 802 1ad Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritizati...

Страница 79: ...s LED Indicator Per Unit Power 1 Green Power 2 Green Fault Red Per Port Link Activity Green PoE Feeding Power Green Housing Metal IP30 protection Dimension 46 x 142 x 99 mm 1 81 x 5 59 x 3 90 in Weigh...

Страница 80: ...6 Vibration Safety UL 508 Pending Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any p...

Отзывы: