4. Hardware Installation 

 

4.1 Installation Steps 

This section will explain how to install Antaira 

Technologies’ IMC-100A (T) series: 10/100Tx to 

100Fx industrial media converter. 

 

Installation Steps 

1.  Unpack the industrial Ethernet media converter from the original packing box. 

2.  Check if the DIN-Rail bracket is screwed on the industrial Ethernet media converter.   

 

If the DIN-Rail is not screwed on the industrial Ethernet media converter, please refer 

to the 

DIN-Rail Mounting

 section for DIN-Rail installation.   

 

If it is required to wall mount the industrial Ethernet media converter, please refer to 

the 

Wall Mounting

 section for wall mounting installation. 

3.  To hang the industrial Ethernet media converter on a DIN-Rail or wall, please refer to the 

Mounting Installation

 section. 

4.  Power on the industrial Ethernet media converter and then the power LED light will turn on. 

 

For the help on how to wire power, please refer to the 

Wiring the Power Inputs

 

section.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

5.  Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection. 

6.  Insert one side of the RJ-45 cable into the media converters Ethernet port and on the other 

side into the networking device’s Ethernet port, e.g. switch PC or server.   

 

The Ethernet port’s (RJ-45) LED on the industrial Ethernet media converter will turn on 

when the cable is connected to the networking device.   

 

Please refer to the 

LED Indicators

 section for LED light indication. 

7.  When all connections are set and the LED lights all show normal, the installation is complete. 

 

 

 

 

 

 

 

 

 

Содержание IMC-100A Series

Страница 1: ...Antaira Technologies Industrial Media Converter LNP 0500G Series User Manual V1 0 i IMC 100A Series 10 100Tx to 100Fx Industrial Media Converter Version 1 0 User Manual...

Страница 2: ...tice Copyrights 2015 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under t...

Страница 3: ...g measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the rece...

Страница 4: ...scription 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 6 2 7 Wiring the Power Inputs 7 2 8 Wiring the Fault Alarm Contact 7 3 Moun...

Страница 5: ...D 10 C to 70 C or an extended temperature range EOT 40 C to 75 C It also provides Ethernet and fiber optic connectivity for outdoor or harsh industrial environment applications such as security survei...

Страница 6: ...Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet media converter s hardware specs ports...

Страница 7: ...nual V1 0 3 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies IMC 100A series 10 100Tx to 100Fx industrial media converter W x D x H...

Страница 8: ...C 100A series media converter that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 12 48VDC Figure 2 2 Front Panel of the IMC 100A Series Figure 2 3 Top Panel View...

Страница 9: ...ower inputs Fiber Port Yellow Green FDX COL Solid Full Duplex Mode Flashing Packet Collision Green Link ACT Networking is active Off Not connected to network RJ45 Ethernet Port Green 100M Linked to ne...

Страница 10: ...ght through and crossover cables 2 6 Cabling Twisted pair segments can be connected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 10...

Страница 11: ...rews to prevent the wires from loosening as shown below in Figure 2 7 Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG 2 8...

Страница 12: ...00A Series User Manual V1 0 8 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate the power f...

Страница 13: ...Mounting The DIN Rail is pre installed on the industrial Ethernet media converter from the factory If the DIN Rail is not on the industrial Ethernet media converter please refer to Figure 3 1 to learn...

Страница 14: ...osite from step 1 3 After the DIN Rail bracket is installed on the rear side of the media converter insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the...

Страница 15: ...e wall mounting brackets on the top and bottom of the industrial media converter 3 Use the screws to screw the wall mounting bracket on the industrial media converter 4 Use the hook holes at the corne...

Страница 16: ...tion 3 To hang the industrial Ethernet media converter on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet media converter and then the power LED...

Страница 17: ...dustrial Media Converter IMC 100A Series User Manual V1 0 13 5 Network Application This segment provides an example of an industrial Ethernet media converter application Figure 5 1 Figure 5 1 Networki...

Страница 18: ...28 feet Diagnosing LED Indicators To assist in identifying problems the media converter can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to t...

Страница 19: ...r1 Green Power2 Green Fault Red Per port Link Activity Green Network Cable 10BaseT 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100BaseTX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m...

Страница 20: ...ntaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu in...

Отзывы: