Antaira Technologies - Industrial Media Converter
IMC-100A Series User Manual V1.0
7
2.7 Wiring the Power Inputs
Please follow the steps below to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in
Figure 2.6
.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure
2.7
.
**Note:
Only use copper conductors,
60/75
°
C
, tighten to
5 lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.
2.8 Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as shown in
Figure 2.8
. By
inserting the wires, it will detect the fault status including any power failures and form
a normal open
circuit. An example is shown in
Figure 2.8
.
Figure 2.7
Power Terminal Block
Figure 2.6
Power Terminal Block