EN
7
NOTE:
The USB charger connection’s total output
current is 4.8 A. The current is disconnected
automatically if the charging current exceeds
this value to protect the connected devices.
ASSEMBLY
INSTALLATION
1. Disconnect the power supply by taking
out the fuse and check that the wires are
without voltage.
2. Strip about 11 mm off the ends of the
wires.
3. Dismantle the product into three parts as
shown in figure 1.
FIG. 1
4. Connect the wires according to the colour
and N and L markings.
FIG. 2
5. Screw the front onto the box. Make sure
not to pinch the wires.
6. Press the frame and panel in place.
SAFETY INSTRUCTIONS
• Do not connect power strips to each other.
• Do not cover the power strip.
ELECTRICAL SAFETY
New installations and extensions to existing
systems should always be carried out by
an authorised electrician. If you have the
necessary experience and knowledge
(otherwise contact an electrician), you can
replace power switches and wall sockets,
fit plugs, extension cords and light sockets.
Incorrect installation can result in fatal injury
and the risk of fire.
SYMBOLS
Read the instructions.
Approved in accordance with the
relevant directives.
Recycle discarded product as electrical
waste.
TECHNICAL DATA
Voltage
230 V ~ 50 Hz
Protection rating
IP20
Current
4.8 A
Size
81x81x45 mm
Recess depth
35 mm
USB CHARGER
Electrical input data 230 V ~ 50 Hz, 200 mA
Electrical output data (total)
5 V, 4.8 A
USB port
USB type A
Содержание 006864